Thermodynamics Examination of Fe3O4-CoFe2O4/Water + EG Nanofluid in a Heated Plate: Crosswise and Stream-wise Aspects

Author(s):  
G. K. Ramesh ◽  
J. K. Madhukesh ◽  
B. C. Prasannakumara ◽  
S. A. Shehzad ◽  
F. M. Abbasi
Keyword(s):  
1972 ◽  
Vol 28 (01) ◽  
pp. 075-088 ◽  
Author(s):  
N. A Marsh ◽  
C. L Arocha-Pinango

SummaryA study was carried out in order to evaluate the Astrup and Mullertz fibrin plate method for estimating plasminogen activators.Choice of a suitable fibrinogen substrate was found to be the most important factor in setting up a workable assay. Many preparations contained a large proportion of non-clottable protein and plates made from these fibrinogens were usually unreliable. In addition, plasminogen content varied appreciably between preparations so that sensitivity of the method required careful calibration with each new batch of fibrinogen.The effect of additives in the fibrin plate was considered and it was found that calcium chloride alone was sufficient to ensure a stabilised plate which could be stored at 4° C for some time. The addition of tranexamic acid (AMCHA) was found to be a slightly more convenient way of estimating direct proteolytic activity, compared with the traditional heated plate. However neither method distinguished completely between proteolysis and plasminogen activation.In order to improve the precision of the method, the use of an analysis of variance technique has been studied. This technique provides information on the dose-response curves of test and unknown substances, and in addition produces an approximately threefold increase in precision over single plate tests.


2005 ◽  
Vol 12 (4) ◽  
pp. 301-313
Author(s):  
S. Z. Shuja ◽  
B. S. Yilbas ◽  
M. O. Budair

AIP Advances ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 065017
Author(s):  
R. J. Noumana Issokolo ◽  
S. E. Mkam Tchouobiap ◽  
F. Naha Nzoupe ◽  
A. M. Dikandé

1973 ◽  
Vol 95 (3) ◽  
pp. 289-294 ◽  
Author(s):  
N. E. Hardwick ◽  
E. K. Levy

The steady, laminar, two-dimensional wake above a thin vertical isothermal heated plate cooled by free convection was investigated theoretically and experimentally. The system of partial differential equations governing the fluid motion and heat transfer in the vicinity of the plate and in the near wake region was formulated and solved using finite difference techniques. Using air, the temperature and velocity profiles in the wake region were measured experimentally using a laser holographic interferometer and a constant temperature hot wire anemometer.


1978 ◽  
Vol 100 (3) ◽  
pp. 429-434 ◽  
Author(s):  
H. Imura ◽  
R. R. Gilpin ◽  
K. C. Cheng

The flow over a horizontal isothermally heated plate at Reynolds numbers below that at which hydrodynamic instabilities exist, is characterized by a region of laminar forced convection near the leading edge, followed by the onset of longitudinal vortices and their growth to a finite amplitude and finally a transition to a turbulent flow regime. Results are presented for the temperature profiles, the thermal boundary layer thickness, and the local Nusselt number. They are used to identify the various flow regimes. It was found that the transition from laminar forced convection to turbulent convection was characterized by the parameter Grx/Rex1.5 falling in the range 100 to 300. For values of this parameter greater than 300 the heat transfer rates were independent of Reynolds number and typical of those for turbulent free convection from a horizontal surface.


Sign in / Sign up

Export Citation Format

Share Document