scholarly journals Growth of centimeter scale carbon wires using in-liquid AC arc discharge

2020 ◽  
Vol 2 (6) ◽  
Author(s):  
Krzysztof Jankowski ◽  
Agnes Ostafin ◽  
Mikołaj Tomasik ◽  
Tebello Nyokong ◽  
Jonathan Britton
Nitric Oxide ◽  
2018 ◽  
Vol 73 ◽  
pp. 89-95 ◽  
Author(s):  
S.R. Li ◽  
Y.F. Huang ◽  
Z. Liu ◽  
M.H. Sui ◽  
J.M. Liu ◽  
...  

1999 ◽  
Vol 195 (2) ◽  
pp. 470-475 ◽  
Author(s):  
Jian Li ◽  
Cunye Liu ◽  
Baogang Zhao ◽  
Yaoqiang Lin ◽  
Zhaojing Deng

2011 ◽  
Vol 2011 ◽  
pp. 1-6 ◽  
Author(s):  
Shenqiang Zhao ◽  
Ruoyu Hong ◽  
Zhi Luo ◽  
Haifeng Lu ◽  
Biao Yan

Carbon nanostructures have received much attention for a wide range of applications. In this paper, we produced carbon nanostructures by decomposition of benzene using AC arc discharge plasma process at atmospheric pressure. Discharge was carried out at a voltage of 380 V, with a current of 6 A–20 A. The products were characterized by scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HRTEM), powder X-ray diffraction (XRD), and Raman spectra. The results show that the products on the inner wall of the reactor and the sand core are nanoparticles with 20–60 nm diameter, and the products on the electrode ends are nanoparticles, agglomerate carbon particles, and multiwalled carbon nanotubes (MWCNTs). The maximum yield content of carbon nanotubes occurs when the arc discharge current is 8 A. Finally, the reaction mechanism was discussed.


1997 ◽  
Vol 12 (1) ◽  
pp. 325-338 ◽  
Author(s):  
M. Farzaneh ◽  
J. Zhang ◽  
X. Chen

2019 ◽  
Vol 85 (1II)) ◽  
pp. 56-59
Author(s):  
M. A. Dombrovskya ◽  
D. G. Lisienko ◽  
O. Yu. Shafar

An arc atomic emission technique of hafnium determination in zirconium is developed and tested. The study was carried out on a PGS-2 spectrometer equipped with MAÉS analyzer and information processing software «Atom 3.3». («VMK-Optoélektronika», Novosibirsk). Excitation of spectra of pre-oxidized metal was carried out using a medium-frequency generator «Vesuvius» («VMK-Optoélektronika», Novosibirsk). Analytical line of hafnium was free of spectral overlap with the lines of zirconium. We have set a current of the AC arc discharge (20 A), exposure time (30 sec) and the form of the electrode into which the sample is placed («narrow crater») are selected. The effect of buffering additives (graphite powder, bismuth fluoride) on the intensity of the analyte lines was studied. It is shown that high sensitivity of the analyte is observed for oxidized material without additives. Reduction of the random error attributed to the influence of conditions of spectrum excitation and sample preparation is achieved using the intensity ratio of the analyte line and zirconium as an analytical signal. Recommendations regarding preparation of the samples for calibration are given. The lower limit of the determined concentration is 0.01% with a relative standard deviation in repeatability 3%.


2004 ◽  
Vol 43 (12) ◽  
pp. 8365-8368 ◽  
Author(s):  
Masato Ohkohchi ◽  
Xinluo Zhao ◽  
Sakae Inoue ◽  
Yoshinori Ando

1997 ◽  
Vol 17 (1) ◽  
pp. 56-57
Author(s):  
M. Farzaneh ◽  
J. Zhang ◽  
X. Chen

Sign in / Sign up

Export Citation Format

Share Document