Protective and Risk Factors for Humerus Head Necrosis After Proximal Humerus Fracture Treated with Internal Locking Plate

Author(s):  
Tomas Da Silva ◽  
David-Benjamin Ehrhard ◽  
Theo Manuel Chuchuy ◽  
Christian Knop ◽  
Tobias Merkle
2021 ◽  
Vol 12 ◽  
pp. 215145932199274
Author(s):  
Hyojune Kim ◽  
Myung Jin Shin ◽  
Erica Kholinne ◽  
Janghyeon Seo ◽  
Duckwoo Ahn ◽  
...  

Purpose: This biomechanical study investigates the optimal number of proximal screws for stable fixation of a 2-part proximal humerus fracture model with a locking plate. Methods: Twenty-four proximal humerus fracture models were included in the study. An unstable 2-part fracture was created and fixed by a locking plate. Cyclic loading and load-to-failure tests were used for the following 4 groups based on the number of screws used: 4-screw, 6-screw, 7-screw, and 9-screw groups. Interfragmentary gaps were measured following cyclic loading and compared. Consequently, the load to failure, maximum displacement, stiffness, and mode of failure at failure point were compared. Results: The interfragmentary gaps for the 4-screw, 6-screw, 7-screw, and 9-screw groups were significantly reduced by 0.24 ± 0.09 mm, 0.08 ± 0.06 mm, 0.05 ± 0.01 mm, and 0.03 ± 0.01 mm following 1000 cyclic loading, respectively. The loads to failure were significantly different between the groups with the 7-screw group showing the highest load to failure. The stiffness of the 7-screw group was superior compared with the 6-screw, 9-screw, and 4-screw groups. The maximum displacement before failure showed a significant difference between the comparative groups with the 4-screw group having the lowest value. The 7-screw group had the least structural failure rate (33.3%). Conclusion: At least 7 screws would be optimal for proximal fragment fixation of proximal humerus fractures with medial comminution to minimize secondary varus collapse or fixation failure. Level of Evidence: Basic science study.


2019 ◽  
Vol 3 (4) ◽  
pp. 256
Author(s):  
Dominique M. Rouleau ◽  
Philippe Moisan ◽  
Julien Goulet ◽  
G.-Yves Laflamme

2010 ◽  
Vol 19 (4) ◽  
pp. 489-494 ◽  
Author(s):  
Philippe Clavert ◽  
Philippe Adam ◽  
Adrien Bevort ◽  
François Bonnomet ◽  
Jean-François Kempf

Author(s):  
Dr. Vivek Amritbhai Patel ◽  
◽  
Dr. Vishal A. Pushkarna ◽  
Dr. Dhruvin J. Patel ◽  
◽  
...  

p>Aim: The present study aimed to examine the functional outcome of the locking plate in theproximal humerus fracture treatment. Material and Methods: The study consists of 20 patientsdiagnosed with NEER’s 2 – part, 3- part, and 4 – part proximal humerus fracture. All the includedpatients were treated with internal locking plates. Based on the functional evaluation by Constant-Murley shoulder score and the assessment of radiological union foundation. Results: Excellentresults were obtained in 45% of the patients, a good result was seen in 25%, 20% of the patientshad fair results and the poor result was seen in 10% of the patients. The mean Constant-Murleyshoulder score that was obtained in the present study was 75.04. Conclusion: It’s concluded thatthere is a satisfactory functional outcome with the fixation of the proximal humerus fracture withlocking plates. While using the plate fixation for fracture the plate position is of the utmostimportance. Due to angular stability, the locking plates are the advantageous implants in case ofproximal humeral fracture.


2013 ◽  
Vol 1 (1) ◽  
pp. 29-32
Author(s):  
Yogesh Gangurde ◽  
◽  
Neetin Mahajan ◽  
Dhiraj Sonawane

2019 ◽  
Vol 34 (4) ◽  
pp. 989-996
Author(s):  
Ivaylo Mitkovski

The proximal humerus is the third most common fracture location in elderly patients after the proximal femoral bone and the distal radial bone. In order to restore the anatomy and bring it as close to normal as possible, blood reposition with internal fixation is a method of choice for unstable fractures. However, surgical treatment is difficult and problematic because of disturbed approach to the fracture and the large fragmentation of pieces. A proximal shoulder bone fracture, which disturbs blood supply of the humeral head, may require placement of prosthesis. Hemiarthroplasty is a logical attitude in such cases, but analysis of functional results and complications has identified a certain number of risk factors limiting indications. Strict analysis of patient characteristics and of fracture type is an essential prerequisite to deciding against treatment by immobilization or osteosynthesis. Results in hemiarthroplasty are primarily dependent on respecting the rules of the art, which aim at stable anatomic osteosynthesis of the surrounding structures so as to restore normal shoulder function. The critical steps are the adjustment of implant height and retroversion, reduction and fixation of tuberosities and good management of the postoperative course. The recent development of fracture-dedicated shoulder implants should improve results. In elderly patients, when local conditions are unsuitable to hemiarthroplasty, a reverse prosthesis may be used, with an adapted surgical technique. Whatever the type of prosthesis, implantation for proximal humerus fracture is a demanding operation with definitive impact on the functional evolution of the shoulder. Following reports of results for shoulder prosthesis in proximal humerus fracture from 1970, several attempts were made to reproduce the encouraging initial findings. Most found good results in terms of pain, but much less satisfactory functional outcome. Analyzing the causes of failure identified risk factors and enabled solutions to be suggested. Among these, one of the first was to select indications, eliminating baseline situations of poor prognosis. Following good results reported in arthropathy involving rotator cuff tear and in revision of hemiarthroplasty for fracture, reverse prostheses were recommended as an alternative attitude in case of proximal humerus fracture in elderly subjects. This particular indication is currently under assessment.This article presents results of a 3-year experience in shoulder endoprothesis after fracture of proximal humerus in elderly patients at Orthopaedics and Traumatology Department, St. Anna General Active Treatment Hospital – Varna, between 2016 and 2018. In this time period, 79 shoulder endoprothesis have been implanted, 68 of which have been actively and carefully observed in the first 12 months of the post-surgery recovery. For the treatment of functional results was utilized Constant Shoulder Score (CSS) that aided following patients’ condition, pain levels, as well as functioning and shoulder movements. Results suggest that in the time span of one year, 51% of the patients show excellent overall recovery state and 38% are in good overall recovery state. These fine results of post-surgery shoulder functioning are in large part due to precise surgery techniques and detailed pre-surgical diagnosis and planning.


Sign in / Sign up

Export Citation Format

Share Document