Dynamic headspace gas chromatographic method for determining volatiles in virgin olive oil

1994 ◽  
Vol 668 (2) ◽  
pp. 455-462 ◽  
Author(s):  
M.T. Morales ◽  
R. Aparicio ◽  
J.J. Rios
1993 ◽  
Vol 76 (2) ◽  
pp. 313-319
Author(s):  
Tore Ramstad ◽  
Lisa S Miller ◽  
Virginia N Thomas

Abstract A dynamic headspace gas chromatographic method was developed for the determination of residual ethylene oxide (EtO) in a pharmaceutical bulk drug, spectinomycin hydrochloride. The recommended column is PoraPLOT Q; PoraPLOT U was demonstrated to be equivalent. A detection limit of 2 ppb was achieved, and linearity was established to the highest value tested (5 ppm). The detection limit was 2-3 orders of magnitude lower than that achieved in previously published methods for EtO in pharmaceutical bulk drugs. Precision studies yielded relative standard deviations ranging from 2 to 10% over the 10-575 ppb concentration range. The method was applied to support EtO sterilization studies conducted at The Upjohn Company and was implemented for routine use. The sterilization studies demonstrated that residual levels of EtO <10 ppb are achievable.


2021 ◽  
Vol 37 (2) ◽  
pp. 321-329
Author(s):  
Nilesh Takale ◽  
Neelakandan Kaliyaperumal ◽  
Gopalakrishnan Mannathusamy ◽  
Rajarajan Govindasamy

The Pharmaceutical industry uses formic acid in the manufacturing of various drug substances or API. At the time of manufacturing of API formic acid is use as an oxidizing agent. Formic acid is the simplest carboxylic acid. It also called methanoic acid.Formic acid present in API at high concentrations is very hazardous but in low concentrations is very beneficial. The developed and validated method was short, precise, cost effective and reproducible with FID detector and easy to use. The method is a selective and superficial analytical method for determination of formic acid in different drug substances. We report here the development and validation study of headspace gas chromatographic method to determine formic acid in different drug substances we are reported here. As per this method, the drug sample was dissolved in 0.1% (v/v) of concentrated sulfuric acid in isopropyl alcohol (IPA) in a GC headspace vial and 0.1% (v/v) of concentrated sulfuric acid in isopropyl alcohol used as a diluent. A AB-Inowax capillary column (30 m x 0.32 mm I.D. and 0.5 µm film thickness) was used under gradient conditions with FID. The formic acid peak was well separated from all other solvents that are used in synthesis of particular drug substance. The LOD and LOQof the method for formic acid are 82 ppm and 249 ppm respectively. Formic acid are low toxic class-III solvent as per ICH guideline.


2012 ◽  
Vol 6 (1) ◽  
pp. 61-68 ◽  
Author(s):  
Anamarija I. Mandić ◽  
Ivana J. Sedej ◽  
Marijana B. Sakač ◽  
Aleksandra Č. Mišan

2019 ◽  
Vol 67 (7) ◽  
pp. 2086-2097 ◽  
Author(s):  
Celia Oliver-Pozo ◽  
Dimitrios Trypidis ◽  
Ramón Aparicio ◽  
Diego L. García-González ◽  
Ramón Aparicio-Ruiz

Sign in / Sign up

Export Citation Format

Share Document