Contrast-enhanced second harmonic blood perfusion measurement

1992 ◽  
Vol 14 (2) ◽  
pp. 201-202
Author(s):  
B Schrope
1993 ◽  
Vol 19 (7) ◽  
pp. 567-579 ◽  
Author(s):  
Beth A. Schrope ◽  
Vernon L. Newhouse

Author(s):  
V.L. Newhouse ◽  
B.A. Schrope ◽  
V. Uhlendorf ◽  
S. Dubin ◽  
M. Victor

Author(s):  
L. A. R. Righesso ◽  
M. Terekhov ◽  
H. Götz ◽  
M. Ackermann ◽  
T. Emrich ◽  
...  

Abstract Objectives Micro-computed tomography (μ-CT) and histology, the current gold standard methods for assessing the formation of new bone and blood vessels, are invasive and/or destructive. With that in mind, a more conservative tool, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), was tested for its accuracy and reproducibility in monitoring neovascularization during bone regeneration. Additionally, the suitability of blood perfusion as a surrogate of the efficacy of osteoplastic materials was evaluated. Materials and methods Sixteen rabbits were used and equally divided into four groups, according to the time of euthanasia (2, 3, 4, and 6 weeks after surgery). The animals were submitted to two 8-mm craniotomies that were filled with blood or autogenous bone. Neovascularization was assessed in vivo through DCE-MRI, and bone regeneration, ex vivo, through μ-CT and histology. Results The defects could be consistently identified, and their blood perfusion measured through DCE-MRI, there being statistically significant differences within the blood clot group between 3 and 6 weeks (p = 0.029), and between the former and autogenous bone at six weeks (p = 0.017). Nonetheless, no significant correlations between DCE-MRI findings on neovascularization and μ-CT (r =−0.101, 95% CI [−0.445; 0.268]) or histology (r = 0.305, 95% CI [−0.133; 0.644]) findings on bone regeneration were observed. Conclusions These results support the hypothesis that DCE-MRI can be used to monitor neovascularization but contradict the premise that it could predict bone regeneration as well.


1999 ◽  
Vol 121 (5) ◽  
pp. 480-486 ◽  
Author(s):  
O. I. Craciunescu ◽  
S. K. Das ◽  
S. T. Clegg

Dynamic contrast-enhanced magnetic resonance imaging (DE-MRI) of the tumor blood pool is used to study tumor tissue perfusion. The results are then analyzed using percolation models. Percolation cluster geometry is depicted using the wash-in component of MRI contrast signal intensity. Fractal characteristics are determined for each two-dimensional cluster. The invasion percolation model is used to describe the evolution of the tumor perfusion front. Although tumor perfusion can be depicted rigorously only in three dimensions, two-dimensional cases are used to validate the methodology. It is concluded that the blood perfusion in a two-dimensional tumor vessel network has a fractal structure and that the evolution of the perfusion front can be characterized using invasion percolation. For all the cases studied, the front starts to grow from the periphery of the tumor (where the feeding vessel was assumed to lie) and continues to grow toward the center of the tumor, accounting for the well-documented perfused periphery and necrotic core of the tumor tissue.


2018 ◽  
Vol 22 (1) ◽  
pp. 31-38 ◽  
Author(s):  
Sunghwa Hong ◽  
Seungjo Park ◽  
Dahae Lee ◽  
Ahyoung Cha ◽  
Dongeun Kim ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Anika Sauerbrey ◽  
Stefan Hindel ◽  
Marc Maaß ◽  
Christine Krüger ◽  
Andreas Wissmann ◽  
...  

The aim of the study was to develop a suitable animal model for validating dynamic contrast-enhanced magnetic resonance imaging perfusion measurements. A total of 8 pigs were investigated by DCE-MRI. Perfusion was determined on the hind leg musculature. An ultrasound flow probe placed around the femoral artery provided flow measurements independent of MRI and served as the standard of reference. Images were acquired on a 1.5 T MRI scanner using a 3D T1-weighted gradient-echo sequence. An arterial catheter for local injection was implanted in the femoral artery. Continuous injection of adenosine for vasodilation resulted in steady blood flow levels up to four times the baseline level. In this way, three different stable perfusion levels were induced and measured. A central venous catheter was used for injection of two different types of contrast media. A low-molecular weight contrast medium and a blood pool contrast medium were used. A total of 6 perfusion measurements were performed with a time interval of about 20–25 min without significant differences in the arterial input functions. In conclusion the accuracy of DCE-MRI-based perfusion measurement can be validated by comparison of the integrated perfusion signal of the hind leg musculature with the blood flow values measured with the ultrasound flow probe around the femoral artery.


2009 ◽  
Vol 30 (5) ◽  
pp. 1139-1144 ◽  
Author(s):  
Ya-Feng Zhang ◽  
Yi-Xiang J. Wang ◽  
James F. Griffith ◽  
William K.M. Kwong ◽  
Heather T. Ma ◽  
...  

Sign in / Sign up

Export Citation Format