COLLECTOR CHARACTERIZATION AND COLLECTOR THERMAL PERFORMANCE TESTING IN TASK III OF THE IEA SOLAR HEATING AND COOLING PROGRAMME

Author(s):  
B A Rogers ◽  
S J Harrison
2020 ◽  
Vol 5 ◽  
pp. 4
Author(s):  
Fernando Antonio de Melo Sá Cavalcanti ◽  
Rosana Maria Caram

In this paper, the thermal performance of a standard environment was evaluated based on the use of a Trombe wall with different configurations and types of use, as the potential for using this passive strategy is still little studied in Brazil. This device is capable of absorbing energy from solar radiation by heating the air in this greenhouse and this heated air can be directed to the interior or exterior of the building depending on the purpose. This air can be used to heat the room or cool it by means of natural ventilation. The analysis of this research was based on a series of computer simulations using the EnergyPlus software, version 7.0 in order to quantify and classify the thermal performance of a standard environment equipped with this component, under the various construction configurations. Both for heating and cooling environments. The use of Trombe walls improved the thermal comfort of users in buildings located in Brazil, depending on the climate where they are located, promoting natural ventilation and passive solar heating, allowing the potential of this device to be investigated in the most diverse Brazilian regions.


2018 ◽  
Vol 12 (1) ◽  
pp. 217-233
Author(s):  
M. Kheradmand ◽  
F. Pacheco-Torgal ◽  
M. Azenha

Background:Energy efficiency is not only the most cost effective way to reduce emissions but also a way to improve competitiveness and create employment. Geopolymeric mortars containing phase change materials-PCMs have a twofold positive impact concerning eco-efficiency. On one hand, the mortars are based on industrial waste contributing for resource efficiency. And on the other hand, PCM based mortars have the capacity to enhance the thermal performance of the buildings.Objective:This paper reports experimental results on the thermal performance of geopolymeric mortars containing different percentages of phase-change materials-PCMs.Method:Five groups of alkali-activated based mortars with different PCM percentages were produced and placed on a panel within a small scale prototype for thermal performance testing.Results:The results show that the thermal conductivity of the mortars decreased with the increase in the percentage of the PCM.Conclusion:Thermal performance of the PCM based mortars allowed for a stronger attenuation of the temperature amplitudes. Both for heating and cooling loads.


2021 ◽  
pp. 111122
Author(s):  
Michal Krajčík ◽  
Martin Šimko ◽  
Ondřej Šikula ◽  
Daniel Szabó ◽  
Dušan Petráš

Author(s):  
Giovanni Nurzia ◽  
Giuseppe Franchini ◽  
Antonio Perdichizzi

The deployment of solar driven air conditioning is a feasible target in all countries where high solar irradiation matches high cooling loads in buildings: the goal is to gradually replace compression chillers and reduce peak electricity demand during summer. Moreover, as solar thermal collectors are installed, solar cooling systems can be profitably employed during winter. In the present work a code has been implemented for the simulation and the design optimization of combined solar heating and cooling systems. The following system layout has been considered: in warm months the cooling demand is satisfied by means of an absorption chiller — driven by a solar collector field — and a reversible heat pump operating in series. A hot storage matches the variability of solar radiation, while a cold storage smoothes the non-stationarity of cooling demand. During winter, the reversible compression heat pump operates for space heating. Solar collectors are used as thermal source at the evaporator of the heat pump, increasing its coefficient of performance. The code, based on TRNSYS platform, is able to simulate the system throughout a year. Besides TRNSYS standard components a detailed model of the absorption chiller has been included, in order to accurately simulate its off-design operation. Using an optimization tool the size of each component is identified for a given space heating and cooling demand. The minimization of life cycle costs of the system has been chosen as the objective of the optimization. Results of a case study are presented and discussed for a solar heating and cooling plant in an office building. The optimization procedure has been carried out with simulations for a typical Northern Italy town (Alpine climate) and a typical Southern Italy town (Mediterranean climate).


Sign in / Sign up

Export Citation Format

Share Document