Self-Calibration Method for Three Dimensional Coordinate Measuring Machines Using a Ball Plate

Author(s):  
L. De Jonge ◽  
J.P. Kruth
2014 ◽  
Vol 981 ◽  
pp. 364-367
Author(s):  
Guang Yu ◽  
Bo Yang Yu ◽  
Shu Cai Yang ◽  
Li Wen ◽  
Wen Fei Dong ◽  
...  

Projector calibration can be seen as a special case of the camera calibration. It can establish the relationship of the three dimensional space coordinates for points and projector image coordinates for points DMD by using a projector to project coding pattern. In camera calibration, ZHANG’s self-calibration was conducted in the maximum likelihood linear refinement. Operation process takes the lens distortion factors into account finding out the camera internal and external parameters finally. Using this algorithm to the projector calibration can solve the traditional linear calibration algorithm which is complex and poor robustness. Otherwise, it can improve the practicability of calibration method. This method can both calibrate the internal and external parameters of projector, which can solve the problem of independently inside or outside calibration.


1997 ◽  
Vol 9 (2) ◽  
pp. 140-145 ◽  
Author(s):  
Jiro Matsuda ◽  

On the basis of the condition that the distances between planes be measured in accordance with the ISO guide ""Uncertainty of Measurement"", the uncertainty of measurement of a CMM in the orthogonal coordinate system has been obtained by carrying out a systematic experiment. So the expanded uncertainty is given as 4.4μm.


2016 ◽  
Vol 40 (4) ◽  
pp. 645-655 ◽  
Author(s):  
Guanbin Gao ◽  
Jing Na ◽  
Xing Wu ◽  
Yu Guo

To improve the accuracy of articulated arm coordinate measuring machines (AACMM) and simplify the calibration process, an improved self-calibration method was proposed. Unlike the traditional calibration methods, which need external expensive precision instruments and elaborate setups, the proposed self-calibration method only requires a gauge to assist the data acquisition operation. By designing a movement trajectory of the AACMM, a series of joint angles can be obtained to form overdetermined equations based on the kinematic model of the AACMM. Therefore, the structural parameters of the AACMM can be obtained by solving the equations. Consequently, the calibration can be achieved by solving these equations. The coefficient matrix of the equations was further analyzed to simplify the equations, and a constructive method was presented to identify the structural parameters by solving the simplified equations with a modified simulated annealing algorithm, in which an optimized search strategy was applied to improve the robustness and efficiency. Experimental studies on an AACMM validate the convenience and effectiveness of the proposed AACMM self-calibration approach.


2011 ◽  
Vol 5 (2) ◽  
pp. 109-114 ◽  
Author(s):  
Hiroyuki Hamana ◽  
◽  
Mitsushi Tominaga ◽  
Miyu Ozaki ◽  
Ryoshu Furutani

Three-dimensional Coordinate Measuring Machines (CMMs) are widely used to measure wide-ranging accuracy. Parameters describing CMM use mechanisms must be calibrated by measuring artifacts for the target CMM. Most CMM calibration studies have covered orthogonal rather than non-orthogonal CMMs. We focused on calibration for a nonorthogonal articulated-Arm CMM (ACMM), which has more measurement freedom than an orthogonal CMM, although ACMM measurement error exceeds that of orthogonal CMMs. The kinematic parameters of ACMM are calibrated using spherical center coordinates as the artifact. Part of the measuring volume is calibrated, but the ACMM is not sufficiently calibrated. To calibrate arm deformation in different measurement posture as well as kinematic parameters, we produced a new artifact for which we propose calibration confirmed in experiments.


Measurement ◽  
2021 ◽  
Vol 174 ◽  
pp. 109067
Author(s):  
Zhi-Feng Lou ◽  
Li Liu ◽  
Ji-Yun Zhang ◽  
Kuang-chao Fan ◽  
Xiao-Dong Wang

Sign in / Sign up

Export Citation Format

Share Document