Stable isotope measurements of atmospheric CO2 and CH4

Author(s):  
B.H. Vaughn ◽  
J. Miller ◽  
D.F. Ferretti ◽  
J.W.C. White
1984 ◽  
Vol 48 (348) ◽  
pp. 311-322 ◽  
Author(s):  
A. P. Dickin ◽  
C. M. B. Henderson ◽  
F. G. F. Gibb

Abstract The Dippin sill, which is emplaced into the Triassic sediments of SE Arran, is an alkaline basic sheet which displays pronounced hydrothermal alteration. The 40-m-thick sill has suffered pervasive contamination with radiogenic Sr, introduced from the Triassic sediments by hydrothermal fluids. Stable isotope measurements suggest that fluids were of meteoric origin, but were restricted to a small closed-system circulation. Initial 87Sr/86Sr ratios in the sill were raised from an original value of 0.7032 to a maximum of 0.7091, contamination being especially pronounced near the contacts at Dippin Head itself (localities 12 and 14) and in a drill core section through the sill above Dippin. Hydrothermal Sr was incorporated into an early-formed high-CaO, high-Sr analcime, which replaced unstable high-silica nepheline in interstitial patches. However, this high-CaO analcime, along with plagioclase, was later replaced by a low-CaO, low-Sr analcime, allowing Sr leaching from the margins of the sill. Hydrothermal fluids are thought to have migrated up to 1 km laterally, up the dip of the sill, mainly via tension joints forming in the cooling intrusion. Pooling of hot fluids at the upper end of the sill probably raised water/rock ratios in this region and allowed greater Sr contamination during mineralogical alteration. The undersaturated mineralogy of the sill accounts for its pervasive hydrothermal Sr contamination, which contrasts markedly with the relatively undisturbed Sr isotope compositions of Hebridean granites involved in hydrothermal systems.


2012 ◽  
Vol 5 (3) ◽  
pp. 4003-4040 ◽  
Author(s):  
L. Huang ◽  
A. Chivulescu ◽  
D. Ernst ◽  
W. Zhang ◽  
Y.-S. Lee

Abstract. Maintaining consistent traceability of high precision measurements of CO2 isotopes is critical in being able to observe accurate atmospheric trends of δ13C (CO2). Although a number of laboratories/organizations around the world have been involved in baseline measurements of atmospheric CO2 isotopes for several decades, the reports on their traceability measures are rare. In this paper, a principle and an approach for the traceability maintenance of high precision isotope measurements (δ13C and δ18O) in atmospheric CO2 is described. The uncertainties of the traceability have been estimated based on the history of annual calibrations over the last 10 yr. The overall uncertainties of CO2 isotope measurements for individual ambient samples carried out by our program at Environment Canada are estimated (excluding the uncertainty associated with the sampling). The values are 0.02‰ and 0.05‰ in δ13C and δ18O, respectively, close to the WMO targets for data compatibility. The annual rate of change in δ13C of the primary anchor used in our program (which is the laboratory standard linking ambient measurements back to the primary VPDB scale) is close to zero (−0.0016 ± 0.0012‰ per year) over the period of 10 yr (2001–2011). The average annual decreasing rate of δ13C in air CO2 measurements at Alert over the period from 1999 to 2010 has been confirmed and verified, which is −0.025 ± 0.003‰ per year. The total change of δ13C in the annual mean value during this period is ∼−0.27‰. The concept of "Big Delta" is introduced and its role in maintaining traceability of the isotope measurements is described and discussed extensively. Finally, the challenges and a strategy for maintaining traceability are also discussed and suggested.


2017 ◽  
pp. 239-256
Author(s):  
Emad Ehtesham ◽  
Federica Camin ◽  
Luana Bontempo ◽  
Russell D. Frew

Radiocarbon ◽  
2002 ◽  
Vol 44 (1) ◽  
pp. 59-62 ◽  
Author(s):  
C M Takahashi ◽  
D E Nelson ◽  
J S Southon

We tested a simple method for removing a collagen-based glue preservative from bone destined for radiocarbon and stable isotope analyses. The method is sufficient for bone samples from which only stable isotope measurements are required. For 14C dating, such samples of age less than about 10 ka can be adequately dated, but for older samples, the circumstances must be carefully evaluated.


Radiocarbon ◽  
2018 ◽  
Vol 60 (5) ◽  
pp. 1533-1545 ◽  
Author(s):  
Nina H Nielsen ◽  
Bente Philippsen ◽  
Marie Kanstrup ◽  
Jesper Olsen

ABSTRACTTollund Man is one of the most famous Iron Age bog bodies due to his well-preserved head. Since he was unearthed in 1950 in Bjældskovdal, Denmark, he has been subjected to several scientific investigations, but until now no attempts to reconstruct his general diet through isotope analyses have been conducted. Furthermore, previous radiocarbon (14C) analyses have only been able to date him broadly to the 3rd–4th century BC. In this study, stable isotope measurements (δ13C, δ15N) on bone collagen from Tollund Man’s femur and rib showed that the diet of Tollund Man was terrestrial-based and that the crops he ate probably were grown on manured fields. Accelerator mass spectrometry (AMS) 14C dates were obtained on both the <30kDa and >30kDa fractions of ultrafiltered collagen. Results showed that the ultrafiltration removed contamination from older substances from the burial environment. The femur was dated to 2330±23 BP, the rib to 2322±30 BP. These dates statistically agree with a previously published AMS 14C age on skin. By combining the new dates with the previous date of his skin it was possible to narrow down the age of Tollund Man to the period 405–380 cal BC (95.4% confidence interval).


Nature ◽  
1978 ◽  
Vol 271 (5645) ◽  
pp. 534-536 ◽  
Author(s):  
R. GONFIANTINI

2016 ◽  
Vol 192 ◽  
pp. 1-28 ◽  
Author(s):  
E.S. Falk ◽  
W. Guo ◽  
A.N. Paukert ◽  
J.M. Matter ◽  
E.M. Mervine ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document