ambient measurements
Recently Published Documents


TOTAL DOCUMENTS

119
(FIVE YEARS 20)

H-INDEX

29
(FIVE YEARS 3)

Author(s):  
Gavin C. Cornwell ◽  
Christina S. McCluskey ◽  
Paul J. DeMott ◽  
Kimberly A. Prather ◽  
Susannah M. Burrows

2021 ◽  
Vol 14 (8) ◽  
pp. 5625-5635
Author(s):  
Jiaoshi Zhang ◽  
Steven Spielman ◽  
Yang Wang ◽  
Guangjie Zheng ◽  
Xianda Gong ◽  
...  

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles is subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ∼10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth and its dependence on both size and RH.


2021 ◽  
Author(s):  
Jiaoshi Zhang ◽  
Steven Spielman ◽  
Yang Wang ◽  
Guangjie Zheng ◽  
Xianda Gong ◽  
...  

Abstract. The ability of aerosol particles to uptake water (hygroscopic growth) is an important determinant of aerosol optical properties and radiative effects. Aerosol hygroscopic growth is traditionally measured by humidified tandem differential mobility analyzers (HTDMA), in which size-selected dry particles are exposed to elevated relative humidity (RH), and the size distribution of humidified particles are subsequently measured using a scanning mobility particle sizer. As a scanning mobility particle sizer can measure only one particle size at a time, HTDMA measurements are time-consuming, and ambient measurements are often limited to a single RH level. Pinterich et al. (2017b) showed that fast measurements of aerosol hygroscopic growth are possible using a humidity-controlled fast integrated mobility spectrometer (HFIMS). In HFIMS, the size distribution of humidified particles is rapidly captured by a water-based fast integrated mobility spectrometer (WFIMS), leading to a factor of ~10 increase in measurement time resolution. In this study we present a prototype HFIMS that extends fast hygroscopic growth measurements to a wide range of atmospherically relevant RH values, allowing for more comprehensive characterizations of aerosol hygroscopic growth. A dual-channel humidifier consisting of two humidity conditioners in parallel is employed such that aerosol RH can be quickly stepped among different RH levels by sampling from alternating conditioners. The measurement sequence is also optimized to minimize the transition time between different particle sizes. The HFIMS is capable of measuring aerosol hygroscopic growth of six particle diameters under five RH levels ranging from 20 % to 85 % (30 separate measurements) every 25 min. The performance of this HFIMS is characterized and validated using laboratory-generated ammonium sulfate aerosol standards. Measurements of ambient aerosols are shown to demonstrate the capability of HFIMS to capture the rapid evolution of aerosol hygroscopic growth, and its dependence on both size and RH.


2021 ◽  
Author(s):  
Paap Koemets ◽  
Sander Mirme ◽  
Kuno Kooser ◽  
Heikki Junninen

<p>The Highly Oxidized Molecule Ion Spectrometer (HOMIS) is a novel instrument for measuring the total concentration of highly oxidized molecules (HOM-s) (Bianchi et al., 2019) at atmospheric pressure. The device combines a chemical ionization charger with a multi-channel differential mobility analyzer. The chemical ionization charger is based on the principles outlined by Eisele and Tanner (1993). The charger is attached to a parallel differential mobility analyzer identical to the ones used in the Neutral cluster and Air Ion Spectrometer (NAIS, Mirme 2011), but with modified sample and sheath air flow rates to improve the mobility resolution of the device. The complete mobility distribution in the range from 3.2 to 0.056 cm<sup>2</sup>/V/s is measured simultaneously by 25 electrometers. The range captures the charger ions, monomers, dimers, trimers but also extends far towards larger particles to possibly detect larger HOM-s that have not been measured with existing instrumentation. The maximum time resolution of the device is 1 second allowing it to detect rapid changes in the sample. The device has been designed to be easy to use, require little maintenance and work reliably in various environments during long term measurements.</p><p>First results of the prototype were acquired from laboratory experiments and ambient measurements. Experiments were conducted at the Laboratory of Environmental Physics, University of Tartu. The sample was drawn from a reaction chamber where alpha-pinene and ozone were introduced. Initial results show a good response when concentrations of alpha-pinene and ozone were changed. </p><p>Ambient measurements were conducted at the SMEAR Estonia measurement station in a hemiboreal forest for 10 days in the spring and two months in the winter of 2020. The HOMIS measurements were performed together with a CI-APi-TOF (Jokinen et al., 2012).</p><p> </p><p>References:</p><p>Bianchi, F., Kurtén, T., Riva, M., Mohr, C., Rissanen, M. P., Roldin, P., Berndt, T., Crounse, J. D., Wennberg, P. O., Mentel, T. F., Wildt, J., Junninen, H., Jokinen, T., Kulmala, M., Worsnop, D. R., Thornton, J. A., Donahue, N., Kjaergaard, H. G. and Ehn, M. (2019), “Highly Oxygenated Organic Molecules (HOM) from Gas-Phase Autoxidation Involving Peroxy Radicals: A Key Contributor to Atmospheric Aerosol”, Chemical Reviews, 119, 6, 3472–3509</p><p>Eisele, F. L., Tanner D. J. (1993), “Measurement of the gas phase concentration of H2SO4 and methane sulfonic acid and estimates of H2SO4 production and loss in the atmosphere”, JGR: Atmospheres, 98, 9001-9010</p><p>Jokinen T., Sipilä M., Junninen H., Ehn M., Lönn G., Hakala J., Petäjä T., Mauldin III R. L., Kulmala M., and Worsnop D. R. (2012), “Atmospheric sulphuric acid and neutral cluster measurements using CI-APi-TOF”, Atmospheric Chemistry and Physics, 12, 4117–4125</p><p>Mirme, S. (2011), “Development of nanometer aerosol measurement technology”, Doctoral thesis, University of Tartu</p>


2020 ◽  
Vol 232 ◽  
pp. 117510
Author(s):  
Chi-Tsan Wang ◽  
Kirsti Ashworth ◽  
Christine Wiedinmyer ◽  
John Ortega ◽  
Peter C. Harley ◽  
...  
Keyword(s):  

2020 ◽  
Vol 20 (10) ◽  
pp. 6081-6094
Author(s):  
Achim Edtbauer ◽  
Christof Stönner ◽  
Eva Y. Pfannerstill ◽  
Matias Berasategui ◽  
David Walter ◽  
...  

Abstract. We present the first ambient measurements of a new marine emission methane sulfonamide (MSAM: CH5NO2S), along with dimethyl sulfide (DMS) and dimethyl sulfone (DMSO2) over the Arabian Sea. Two shipborne transects (W → E, E → W) were made during the AQABA (Air Quality and Climate Change in the Arabian Basin) measurement campaign. Molar mixing ratios in picomole of species per mole of air (throughout this paper abbreviated as ppt) of DMS were in the range of 300–500 ppt during the first traverse of the Arabian Sea (first leg) and 100–300 ppt on the second leg. On the first leg DMSO2 was always below 40 ppt and MSAM was close to the limit of detection. During the second leg DMSO2 was between 40 and 120 ppt and MSAM was mostly in the range of 20–50 ppt with maximum values of 60 ppt. An analysis of HYSPLIT back trajectories combined with calculations of the exposure of these trajectories to underlying chlorophyll in the surface water revealed that most MSAM originates from the Somalia upwelling region, known for its high biological activity. MSAM emissions can be as high as one-third of DMS emissions over the upwelling region. This new marine emission is of particular interest as it contains both sulfur and nitrogen, making it potentially relevant to marine nutrient cycling and marine atmospheric particle formation.


2020 ◽  
Vol 20 (5) ◽  
pp. 3249-3258 ◽  
Author(s):  
Athanasios Nenes ◽  
Spyros N. Pandis ◽  
Rodney J. Weber ◽  
Armistead Russell

Abstract. Nitrogen oxides (NOx) and ammonia (NH3) from anthropogenic and biogenic emissions are central contributors to particulate matter (PM) concentrations worldwide. The response of PM to changes in the emissions of both compounds is typically studied on a case-by-case basis, owing in part to the complex thermodynamic interactions of these aerosol precursors with other PM constituents. Here we present a simple but thermodynamically consistent approach that expresses the chemical domains of sensitivity of aerosol particulate matter to NH3 and HNO3 availability in terms of aerosol pH and liquid water content. From our analysis, four policy-relevant regimes emerge in terms of sensitivity: (i) NH3 sensitive, (ii) HNO3 sensitive, (iii) NH3 and HNO3 sensitive, and (iv) insensitive to NH3 or HNO3. For all regimes, the PM remains sensitive to nonvolatile precursors, such as nonvolatile cations and sulfate. When this framework is applied to ambient measurements or predictions of PM and gaseous precursors, the “chemical regime” of PM sensitivity to NH3 and HNO3 availability is directly determined. The use of these regimes allows for novel insights, and this framework is an important tool to evaluate chemical transport models. With this extended understanding, aerosol pH and associated liquid water content naturally emerge as previously ignored state parameters that drive PM formation.


Sign in / Sign up

Export Citation Format

Share Document