786 Assessment of long-term follow-up results of circumferential pulmonary veins RF catheter ablation in patients with paroxysmal atrial fibrillation- usefulness of 7-days Holter recording

EP Europace ◽  
2005 ◽  
Vol 7 (Supplement_1) ◽  
pp. 179-179
Author(s):  
K. Szydlo ◽  
A. Wnuk-Wojnar ◽  
M. Trusz-Gluza ◽  
I. Wozniak-Skowerska ◽  
C. Czerwinski ◽  
...  
QJM ◽  
2020 ◽  
Vol 113 (Supplement_1) ◽  
Author(s):  
O H M A Riad ◽  
T Wong ◽  
A N Ali ◽  
M T Ibrahim ◽  
M A Abdelhamid ◽  
...  

Abstract Background Pulmonary vein isolation (PVI) has become the mainstay of catheter ablation of atrial fibrillation (AF). There are two commonly used methods to isolate the pulmonary veins, either point-by-point delivery of circumferential lesion sets around ipsilateral pulmonary veins using radiofrequency energy, or the application of the cryoballoon to the pulmonary vein antrum with occlusion of the vein ostium. The cryoballoon has proven to be a reliable alternative to radiofrequency ablation in acute and long-term freedom from AF. We describe our results using both modalities. Aim and Objectives to compare the safety and efficacy of cryoballoon (CB) ablation and radiofrequency (RF) ablation in treatment of paroxysmal atrial fibrillation. Patients and Methods Forty-four consecutive patients having paroxysmal AF underwent PVI using the second generation cryoballoon were compared to a retrospective cohort of 69 patients who had radiofrequency induced PVI, either by conventional RF catheter (n = 32), or a contact-force sensing-catheter (n = 37). The study took place at Ain Shams university hospitals and Royal Brompton & Harefield NHS trust. Patient data, procedural data and follow up data- at 3, 6 and 12 months- were collected and analysed. Recurrence was defined as documented AF or atrial arrhythmias with duration exceeding 30 seconds, either by 12 lead ECG or an ambulatory monitoring device. Results A total of 113 patients were studied. The mean age was 53.84 ± 15.01 for the CB group and 55.78 ± 14.84 for the RF group and females representing 40.9% vs 34.8% respectively. The mean procedural times in minutes were significantly less in the CB group (94.37 ± 39.32 vs 184.57 ± 88.19, p < 0.0001), while the median fluoroscopy times were similar [30 (11.04 - 40) vs 37.25 (14.2 - 70), p = 0.172]. Procedural complications were comparable between the two groups (p = 0.06) with 1 patient (2.3%) having long term phrenic nerve paresis. At 1 year follow up, after an initial 90-day blanking period, recurrence rate of CB was similar to RF (27.3% vs 30.4% respectively, p = 0.719), the Kaplan Meier estimates of AF- free survival for a period of 1 year were comparable between both groups (log rank test, p = 0.606). Conclusion Cryoballoon is a feasible method for pulmonary vein isolation with similar success rates to radiofrequency ablation. Cryoballoon ablation is safe with shorter duration of the procedure.


2011 ◽  
Vol 27 (Supplement) ◽  
pp. OP23_4
Author(s):  
Keiichi Hishikari ◽  
Hiroshi Taniguchi ◽  
Shigeki Kusa ◽  
Kei Takayama ◽  
Takashi Uchiyama ◽  
...  

2014 ◽  
Vol 7 (2) ◽  
pp. 267-273 ◽  
Author(s):  
Masateru Takigawa ◽  
Atsushi Takahashi ◽  
Taishi Kuwahara ◽  
Kenji Okubo ◽  
Yoshihide Takahashi ◽  
...  

Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Xue Zhao ◽  
Jianqiang Hu ◽  
Yan Huang ◽  
Yawei Xu ◽  
Yanzhou Zhang ◽  
...  

Objectives: The aim of this study was to determine the mechanisms and effectiveness of pulmonary antrum radial-linear (PAR) ablation in comparison with pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF) after a long-term follow-up. Background: The one-year follow up data suggested that PAR ablation appeared to have a better outcome over the conventional PVI for paroxysmal AF. Methods: The enrollment occurred between March, 2011, and August, 2011, with the last follow-up in May, 2014. A total of 133 patients with documented paroxysmal AF were enrolled from 5 centers and randomized to PAR group or PVI group. Event ECG recorder and Holter monitoring were conductedduring the follow-up for all patients. Results: The average procedure time was 151±23 min in PAR group and 178±43 min in PVI group ( P <0.001). The average fluoroscopy time was 21±7 min in PAR group and 27±11 min in PVI group ( P= 0.002). AF triggering foci were eliminated in 59 patients (89.4%) in PAR group, whereas, only 4 patients (6.0%) in PVI group (P<0.001).At median 36 (37-35) months of follow-up after single ablation procedure, 43 of 66 patients in PAR group (65%) and 28 of 67 patients in PVI group (42%) had no recurrence of AF off antiarrhythmic drug (AAD) (P=0.007); and 47 of 66 patients in PAR group (71%) and 32 of 67 patients in PVI group (48%) had no recurrence of AF with AAD (P=0.006). At the last follow-up, the burden of AF was significantly lower in PAR group than in PVI group (0.9% ± 2.3% vs 4.9% ± 9.9%;90th percentile, 5.5% vs 19.6%; P=0.008). No major adverse event (death, stroke, PV stenosis) was observed in all the patients except one case of pericardial tamponade. Conclusions: PAR ablation is a simple, safe, and effective strategy for the treatment of paroxysmal AF with better long-term outcome than PVI. PAR ablation might exhibit the beneficial effect on AF management through multiple mechanisms. Registration: ChiCTR-TRC-11001191


Sign in / Sign up

Export Citation Format

Share Document