Does Clinical Pretest Probability Influence Image Quality and Diagnostic Accuracy in Dual-Source Coronary CT Angiography?

2010 ◽  
Vol 17 (2) ◽  
pp. 212-218 ◽  
Author(s):  
Christoph Thomas ◽  
Harald Brodoefel ◽  
Ilias Tsiflikas ◽  
Friederike Bruckner ◽  
Anja Reimann ◽  
...  
2008 ◽  
Vol 2 (2) ◽  
pp. 105-114 ◽  
Author(s):  
Damini Dey ◽  
Cynthia J. Lee ◽  
Muneo Ohba ◽  
Ariel Gutstein ◽  
Piotr J. Slomka ◽  
...  

2015 ◽  
Vol 120 (12) ◽  
pp. 1112-1121 ◽  
Author(s):  
Julian L. Wichmann ◽  
Xiaohan Hu ◽  
Alexander Engler ◽  
J. Matthias Kerl ◽  
Martin Beeres ◽  
...  

2014 ◽  
Vol 24 (7) ◽  
pp. 1643-1650 ◽  
Author(s):  
Felix G. Meinel ◽  
Christian Canstein ◽  
U. Joseph Schoepf ◽  
Martin Sedlmaier ◽  
Bernhard Schmidt ◽  
...  

Radiology ◽  
2008 ◽  
Vol 248 (3) ◽  
pp. 792-798 ◽  
Author(s):  
Annick C. Weustink ◽  
Nico R. Mollet ◽  
Francesca Pugliese ◽  
Willem B. Meijboom ◽  
Koen Nieman ◽  
...  

2015 ◽  
Vol 26 (9) ◽  
pp. 2937-2946 ◽  
Author(s):  
Stefanie Mangold ◽  
Julian L. Wichmann ◽  
U. Joseph Schoepf ◽  
Sheldon E. Litwin ◽  
Christian Canstein ◽  
...  

2021 ◽  
pp. 1-11
Author(s):  
Wen Qian ◽  
Wangyan Liu ◽  
Yinsu Zhu ◽  
Jun Wang ◽  
Yang Chen ◽  
...  

BACKGROUND: CT-derived fractional flow reserve (FFRCT) and diagnostic accuracy rely on good image quality during coronary CT angiography (CCTA). OBJECTIVE: To investigate whether heart rate (HR) and coronary artery calcium (CAC) score decrease image quality and diagnostic performance of two advanced CT scanners including 96-row detector dual source CT (DSCT) and 256-row multidetector CT (MDCT). METHODS: First, 79 patients who underwent CCTA (42 with DSCT and 37 with MDCT) and invasive coronary angiography (ICA) are enrolled. Next, coronary segments with excellent image quality are evaluated and the percentage is calculated. Then, diagnostic accuracy in detecting significant diameter stenosis is presented with ICA as the reference standard. RESULTS: Compared with the DSCT, the percentage of coronary segments with excellent image quality is lower (P = 0.010) while diagnostic accuracy on per-segment level is improved (P = 0.037) using MDCT. CAC score≥400 is the only independent factor influencing the percentage of coronary segments with excellent image quality [odds ratio (OR): DSCT, 3.096 and MDCT, 1.982] and segmental diagnostic accuracy (OR: DSCT, 2.630 and MDCT, 2.336) for both scanners. HR≥70 bpm (OR: 5.506) is the independent factor influencing the percentage of coronary segments with excellent image quality with MDCT. CONCLULSION: During CCTA, CAC score≥400 still decreases the proportion of coronary segments with excellent image quality and diagnostic accuracy with advanced CT scanners. HR≥70 bpm is another factor causing image quality decreasing with MDCT.


Sign in / Sign up

Export Citation Format

Share Document