The Importance of Accurate Tumor Measurements and Staging in Oncologic Imaging: Impact on Patients’ Health

Author(s):  
Paolo Spinnato
2020 ◽  
Vol 8 (Suppl 3) ◽  
pp. A224-A225
Author(s):  
Mary Woodall-Jappe ◽  
A Raghav Chari ◽  
Anil Namboodiripad ◽  
Chandrasekhar Goda

BackgroundRegulatory T cell (Tregs) inhibit activity of anti-tumor T cells, and have been shown to limit checkpoint inhibitor effectiveness. Depletion of Tregs seems desirable during immunotherapy, but chronic Treg depletion with antibody therapies can lead to serious autoimmune adverse events. Compared to antibodies, the fusion protein E7777 (IL-2/diphtheria toxin) has a relatively short half-life in circulation, which allows for transient and selective Treg depletion. The potential therapeutic benefit of combining E7777 with anti-PD-1 was tested in syngeneic solid tumor models.MethodsCT26 colon and H22 liver cancer tumors were implanted subcutaneously in immunocompetent BALB/c mice. E7777 (2.5 mcg/mouse, i.v.) was given on a Q7Dx3 schedule. Anti-murine PD-1 was given (100 mcg/mouse, i.v.) Q4Dx5. Groups of 16 mice received each agent as monotherapy or in combinations. Sequencing of combination administration was also varied: Group 4 started treatment on the same day; Group 5 received E7777 2 days prior to start of anti-PD-1; Group 6 received anti-PD-1 first. Tumor growth was compared across all groups. In survival studies, mice were treated for 3 weeks and observed with twice weekly tumor measurements. In other experiments, tumors, tumor-draining lymph nodes, and spleens were examined by IHC and by flow cytometry of immune cells from dissociated tissues at defined points, for immune biomarkers.ResultsFigure 1 shows additive benefit from the E7777 + anti-PD-1 combinations over either monotherapy. Most importantly, figure 2 and table 1 show significantly enhanced overall survival from a 3 week course of combinations compared to either agent alone (p<0.005) or to vehicle controls (p<0.000001). There was no clear distinction among different sequencing regimens. Benefit correlated with enhanced CD8:Treg ratios in tumors.Abstract 208 Figure 1Tumor growth in s.c. syngeneic solid tumors. N=16/groupAbstract 208 Figure 2Overall survival in s.c. syngeneic models. N=16/groupAbstract 208 Table 1Calculated median survivalConclusionsDepletion of Tregs by E7777 significantly increased anti-tumor activity and durably extended overall survival compared to treatment with anti-PD-1 alone in syngeneic solid tumor models. Clinical studies of a combination of the two agents are planned.Ethics ApprovalAll studies were conducted at Crown Bio, and were approved by the Crown Bio IACUC.


1987 ◽  
Vol 5 (8) ◽  
pp. 1143-1149 ◽  
Author(s):  
A A Forastiere ◽  
M Gennis ◽  
M B Orringer ◽  
F P Agha

Thirty-six patients with adenocarcinoma or epidermoid carcinoma of the esophagus were entered into a phase II trial evaluating the combination of cisplatin 100 mg/m2 intravenously (IV) day 2, vinblastine 1.6 mg/m2 IV days 1 to 4, and mitoguazone (MGBG) 500 mg/m2 IV days 1 and 8. Twenty-nine patients (group A) were newly diagnosed with local-regional disease only and were candidates for transhiatal esophagectomy (THE). These patients received two courses of chemotherapy at 3-week intervals prior to surgery. Response was assessed by measuring changes in the primary tumor length and depth on serial biphasic contrast esophagrams and comparing this result with tumor measurements obtained from the surgical specimen. Complete (CR) and partial responders (PR) received three additional postoperative cycles. Seven patients had recurrent or metastatic disease (group B) and were treated every 4 weeks until disease progression. Of 34 patients evaluable for response, there was one pathologically confirmed CR and 15 PRs (47%). This consisted of 12 of 27 (44%) group A patients (seven of 11 epidermoid, five of 16 adenocarcinoma) and four of seven (57%) group B patients (two of four epidermoid, two of three adenocarcinoma). Toxicity included leukopenia in one third of treatment courses and thrombocytopenia in 21%. Nausea and vomiting occurred in 60% of patients, diarrhea in 18%, transient nephrotoxicity in 18%, peripheral neuropathy in 12%, and ototoxicity in 3%. Twenty-five group A patients underwent resection. Four chemotherapy nonresponders (NR) and one PR had known disease left at surgery; all others (80%) had gross total removal of their disease. The median survival time (MST) of the 29 group A patients was 14 months, with 21% alive at 36 months. The MST of group A chemotherapy responders was 15 months compared with 9 months for NRs (P = .032). Initial sites of recurrence in 14 patients were local-regional in six, distant only in six, both local-regional and distant in two. This regimen, administered in maximally tolerated doses, was active in epidermoid and adenocarcinoma histologies, recurrent disease and newly diagnosed patients. However, nearly all responses were PRs and the MST of resected patients was similar to a prior series of patients treated with esophagectomy alone. Observations from this pilot trial and those of others have led to a follow-up study, in progress, evaluating intensive preoperative chemotherapy and concurrent radiation therapy (RT).


2018 ◽  
Vol 150 (6) ◽  
pp. 499-506 ◽  
Author(s):  
Kevin R Anderson ◽  
Allison Onken ◽  
Benedikt H Heidinger ◽  
Yigu Chen ◽  
Alexander A Bankier ◽  
...  

Abstract Objectives The eighth edition of the American Joint Committee on Cancer staging manual now stratifies nonmucinous lung adenocarcinomas (nmLACAs) by the size of the invasive component only. This is determined by direct gross or microscopic measurement; however, a calculated invasive size based on the percentage of invasive growth patterns has been proposed as an alternative option. Methods To compare radiologic with different pathologic assessments of invasive tumor size, we retrospectively reviewed a cohort of resected nmLACAs with a part-solid appearance on computed tomography (CT) scan (n = 112). Results The median direct microscopic pathologic invasive measurements were not significantly different from the median calculated pathologic invasive measurements; however, the median CT invasive measurements were 0.26 cm larger than the median direct pathologic measurements (P < .001). Conclusions Our results show that pathologic calculated invasive tumor measurements are comparable to direct microscopic measurements of invasive tumor, thereby supporting the recommendation for use of calculated invasive tumor size by the pathologist if necessary.


2013 ◽  
Vol 201 (2) ◽  
pp. 237-245 ◽  
Author(s):  
Pedram Rezai ◽  
Mark J. Pisaneschi ◽  
Chun Feng ◽  
Vahid Yaghmai

2017 ◽  
Author(s):  
Heung Sik Kang ◽  
Joon Woo Lee ◽  
Eugene Lee

2000 ◽  
Vol 18 (10) ◽  
pp. 2179-2184 ◽  
Author(s):  
Lawrence H. Schwartz ◽  
Michelle S. Ginsberg ◽  
Douglas DeCorato ◽  
Lawrence N. Rothenberg ◽  
Steven Einstein ◽  
...  

PURPOSE: To evaluate the variability in bidimensional computed tomography (CT) measurements obtained of actual tumors and of tumor phantoms by use of three measurement techniques: hand-held calipers on film, electronic calipers on a workstation, and an autocontour technique on a workstation. MATERIALS AND METHODS: Three radiologists measured 45 actual tumors (in the lung, liver, and lymph nodes) on CT images, using each of the three techniques. Bidimensional measurements were recorded, and their cross-products calculated. The coefficient of variation was calculated to assess interobserver variability. CT images of 48 phantoms were measured by three radiologists with each of the techniques. In addition to the coefficient of variation, the differences between the cross-product measurements of tumor phantoms themselves and the measurements obtained with each of the techniques were calculated. RESULTS: The differences between the coefficients of variation were statistically significantly different for the autocontour technique, compared with the other techniques, both for actual tumors and for tumor phantoms. There was no statistically significant difference in the coefficient of variation between measurements obtained with hand-held calipers and electronic calipers. The cross-products for tumor phantoms were 12% less than the actual cross-product when calipers on film were used, 11% less using electronic calipers, and 1% greater using the autocontour technique. CONCLUSION: Tumor size is obtained more accurately and consistently between readers using an automated autocontour technique than between those using hand-held or electronic calipers. This finding has substantial implications for monitoring tumor therapy in an individual patient, as well as for evaluating the effectiveness of new therapies under development.


2008 ◽  
Vol 8 (1) ◽  
pp. 87-92 ◽  
Author(s):  
M. Beth McCarville
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document