Experimental study on breakdown voltage of high pressure and high temperature helium gas between parallel electrodes

2017 ◽  
Vol 110 ◽  
pp. 1224-1231 ◽  
Author(s):  
Xingnan Liu ◽  
Zhengang Shi ◽  
Guojun Yang ◽  
Xunshi Yan
2016 ◽  
Vol 174 (3) ◽  
pp. 1033-1041 ◽  
Author(s):  
KeShi Hui ◽  
LiDong Dai ◽  
HePing Li ◽  
HaiYing Hu ◽  
JianJun Jiang ◽  
...  

2019 ◽  
Author(s):  
Mohd Fakrumie Zaidin ◽  
Budi Priyatna Kantaatmadja ◽  
Antonin Chapoy ◽  
Pehzman Ahmadi ◽  
Rod Burgass

2012 ◽  
Vol 594-597 ◽  
pp. 2073-2076
Author(s):  
Zhong Fei Ma ◽  
Li Chen ◽  
Fu Qin Wang

In order to improve the cooling effect and practical applicability of falling temperature technique on high-temperature workplaces, the aeration and cooling principle of the high pressure water rotational jetting ventilation were analysed, and the experimental study was carried out. The results show that water pressure and cooling rate are an approximation of parabolic growth relationship, different structure of jet tube and temperature difference on water and gas also have an obvious effect on the cooling amplitude and air quantity. the guide vanes installed may improve effect of ventilation and cooling the capacity on high pressure water rotational jetting.


2020 ◽  
Author(s):  
Sarah Incel

<p>Impact rocks often reveal particular structures, e.g. shock-induced amorphization and melting of crystals, that formed due to high stresses during shock metamorphism. This experimental study presents four granulite samples that were deformed in a D-DIA apparatus at 2.5 GPa and 3 GPa and at either 1023 K, 1173 K, or at 995 to 1225 K. During deformation of two samples (2.5 GPa and either 995-1125 K or 1173 K) 82 and 794 acoustic emissions (AEs) were recorded, respectively, whereas less than 10 AEs were recorded while deforming the other two granulite sample (3 GPa and 995-1225 K; 2.5 and 1073 K). Microstructures of the samples that emitted 82 and 794 AEs reveal amorphous patches that are absent in the samples corresponding to the runs in which <10 AEs were recorded, indicating a link between AE-activity and amorphization of plagioclase. The contacts between amorphous patches and host-plagioclase crystals are very sharp and amorphization predominantly occurred along two distinct planes inclined at approx. 45° towards the direction of maximum compression. Surrounding the patches, the hosts show extensive fragmentation. Chemical analyses of the amorphous patches demonstrate an enrichment in potassium and silicon relative to the initial plagioclase chemistry and the growth of euhedral quartz crystals within the patches. Such microstructures were previously found in naturally or experimentally shocked rocks and interpreted as shock melts. The occurrence of structures, revealing striking similarities to shock melts, in experimental samples that underwent embrittlement at high-pressure, high-temperature conditions below the sample’s solidus (~1377 K) suggests melting due to elevated transient stresses, e.g. during rupture processes.</p>


1998 ◽  
Vol 43 (3) ◽  
pp. 249-253
Author(s):  
Fulai Liu ◽  
Qihan Shen ◽  
Yuansheng Geng ◽  
Xuechun Xu ◽  
Rui Ma

2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Beibei Feng ◽  
Shiming Wang ◽  
Shengqiang Li ◽  
Xingtuan Yang ◽  
Shengyao Jiang

Numerical simulation is performed to investigate the pressure distribution of helium gas under high pressure and high temperature for 10 MW High Temperature Gas-Cooled Reactor (HTGR-10). Experimental studies are first conducted on a self-built test system to investigate the static pressure distribution of a 90° elbow and validate the credibility of the computational approach. The 90° elbow is designed and manufactured geometrically the same as HTGR-10. Based on the experimental data, comparison of static pressure of inner wall and outer wall of 90° elbow with numerical results is carried out to verify the numerical approach. With high agreement between experimental results and numerical results of water flowing through 90° elbow, flow characteristics of helium gas under high pressure and high temperature are investigated on the confirmed numerical approach for flow measurement. And wall pressure distribution of eight cross sections of 90° elbow is given in detail to represent the entire region of the elbow.


Sign in / Sign up

Export Citation Format

Share Document