Getting insight in the performance of noise interventions by mobile sound level measurements

2022 ◽  
Vol 185 ◽  
pp. 108385
Author(s):  
Timothy Van Renterghem ◽  
Pieter Thomas ◽  
Luc Dekoninck ◽  
Dick Botteldooren
Keyword(s):  
2020 ◽  
Vol 63 (8) ◽  
pp. 2597-2608
Author(s):  
Emily N. Snell ◽  
Laura W. Plexico ◽  
Aurora J. Weaver ◽  
Mary J. Sandage

Purpose The purpose of this preliminary study was to identify a vocal task that could be used as a clinical indicator of the vocal aptitude or vocal fitness required for vocally demanding occupations in a manner similar to that of the anaerobic power tests commonly used in exercise science. Performance outcomes for vocal tasks that require rapid acceleration and high force production may be useful as an indirect indicator of muscle fiber complement and bioenergetic fitness of the larynx, an organ that is difficult to study directly. Method Sixteen women (age range: 19–24 years, M age = 22 years) were consented for participation and completed the following performance measures: forced vital capacity, three adapted vocal function tasks, and the horizontal sprint test. Results Using a within-participant correlational analyses, results indicated a positive relationship between the rate of the last second of a laryngeal diadochokinesis task that was produced at a high fundamental frequency/high sound level and anaerobic power. Forced vital capacity was not correlated with any of the vocal function tasks. Conclusions These preliminary results indicate that aspects of the laryngeal diadochokinesis task produced at a high fundamental frequency and high sound level may be useful as an ecologically valid measure of vocal power ability. Quantification of vocal power ability may be useful as a vocal fitness assessment or as an outcome measure for voice rehabilitation and habilitation for patients with vocally demanding jobs.


Author(s):  
David C. Byrne ◽  
Christa L. Themann ◽  
Deanna K. Meinke ◽  
Thais C. Morata ◽  
Mark R. Stephenson

An audiologist should be the principal provider and advocate for all hearing loss prevention activities. Many audiologists equate hearing loss prevention with industrial audiology and occupational hearing conservation programs. However, an audiologist’s involvement in hearing loss prevention should not be confined to that one particular practice setting. In addition to supervising occupational programs, audiologists are uniquely qualified to raise awareness of hearing risks, organize public health campaigns, promote healthy hearing, implement intervention programs, and monitor outcomes. For example, clinical audiologists can show clients how to use inexpensive sound level meters, noise dosimeters, or phone apps to measure noise levels, and recommend appropriate hearing protection. Audiologists should identify community events that may involve hazardous exposures and propose strategies to minimize risks to hearing. Audiologists can help shape the knowledge, beliefs, motivations, attitudes, and behaviors of individuals toward self-protection. An audiologist has the education, tools, opportunity, and strategic position to facilitate or promote hearing loss surveillance and prevention services and activities. This article highlights real-world examples of the various roles and substantial contributions audiologists can make toward hearing loss prevention goals.


Author(s):  
Dr. Hitesh Paghadar

Increasing environment noise pollution is a matter of great concern and of late has been attracting public attention. Sound produces the minute oscillatory changes in air pressure and is audible to the human ear when in the frequency range of 20Hz to 20 kHz. The chief sources of audible sound are the magnetic circuit of transformer which produces sound due to magnetostriction phenomenon, vibration of windings, tank and other structural parts, and the noise produced by cooling equipments. This paper presents the validation for sound level measurement scale, why A-weighted scale is accepted for sound level measurement, experimental study carried out on 10MVA Power Transformer. Also presents the outcomes of comparison between No-Load sound & Load sound level measurement, experimental study carried out on different transformer like - 10MVA, 50MVA, 100MVA Power Transformer, to define the dominant factor of transformer sound generation.


2019 ◽  
Vol 45 (4) ◽  
pp. 398-410 ◽  
Author(s):  
Ronald A. Kastelein ◽  
Léonie A. E. Huijser ◽  
Suzanne Cornelisse ◽  
Lean Helder-Hoek ◽  
Nancy Jennings ◽  
...  

2010 ◽  
Vol 35 (4) ◽  
pp. 543-550 ◽  
Author(s):  
Wojciech Batko ◽  
Bartosz Przysucha

AbstractAssessment of several noise indicators are determined by the logarithmic mean <img src="/fulltext-image.asp?format=htmlnonpaginated&src=P42524002G141TV8_html\05_paper.gif" alt=""/>, from the sum of independent random resultsL1;L2; : : : ;Lnof the sound level, being under testing. The estimation of uncertainty of such averaging requires knowledge of probability distribution of the function form of their calculations. The developed solution, leading to the recurrent determination of the probability distribution function for the estimation of the mean value of noise levels and its variance, is shown in this paper.


Sign in / Sign up

Export Citation Format

Share Document