Hydrogen production using the waste heat of Benchmark pressurized Molten carbonate fuel cell system via combination of organic Rankine cycle and proton exchange membrane (PEM) electrolysis

2017 ◽  
Vol 114 ◽  
pp. 631-638 ◽  
Author(s):  
Hossein Nami ◽  
Ehsan Akrami ◽  
Faramarz Ranjbar
2021 ◽  
Vol 13 (3) ◽  
pp. 1218
Author(s):  
Sharjeel Ashraf Ansari ◽  
Mustafa Khalid ◽  
Khurram Kamal ◽  
Tahir Abdul Hussain Ratlamwala ◽  
Ghulam Hussain ◽  
...  

The proton exchange membrane fuel cell (PEMFC) is the fastest growing fuel cell technology on the market. Due to their sustainable nature, PEMFCs are widely adopted as a renewable energy resource. Fabricating a PEMFC is a costly process; hence, mathematical modeling and simulations are necessary in order to fully optimize its performance. Alongside this, the feasibility of a waste heat recovery system based on the organic Rankine cycle is also studied and power generation for different operating conditions is presented. The fuel cell produces a power output of 1198 W at a current of 24A. It has 50% efficiency and hence produces an equal amount of waste heat. That waste heat is used to drive an organic Rankine cycle (ORC), which in turn produces an additional 428 W of power at 35% efficiency. The total extracted power hence stands at 1626 W. MATLAB/Simulink R2016a is used for modeling both the fuel cell and the organic Rankine cycle.


2019 ◽  
Vol 11 (12) ◽  
pp. 3264 ◽  
Author(s):  
S. M. Seyed Mahmoudi ◽  
Niloufar Sarabchi ◽  
Mortaza Yari ◽  
Marc A. Rosen

Comprehensive exergy and exergoeconomic assessments are reported for a proposed power producing system, in which an organic Rankine cycle is employed to utilize the waste heat from the fuel cell stack. A complete mathematical model is presented for simulating the system performance while considering water management in the fuel cell. The simulation is performed for individual components of the fuel cell system, e.g., the compressor and humidifiers. A parametric study is conducted to evaluate the effects on the system’s thermodynamic and economic performance of parameters, such as the fuel cell operating pressure, current density, and turbine back pressure. The results show that an increase in the fuel cell operating pressure leads to a higher exergy efficiency and exergoeconomic factor for the overall system. In addition, it is observed that the overall exergy efficiency is 4.16% higher than the corresponding value that is obtained for the standalone fuel cell for the same value of fuel cell operating pressure. Furthermore, the results indicate that the compressor and condenser exhibit the worst exergoeconomic performance and that the exergoeconomic factor, the capital cost rate and the exergy destruction cost rate for the overall system are 40.8%, 27.21 $/h, and 39.49 $/h, respectively.


2005 ◽  
Vol 2 (4) ◽  
pp. 263-267 ◽  
Author(s):  
Darrell D. Massie ◽  
Daisie D. Boettner ◽  
Cheryl A. Massie

As part of a one-year Department of Defense demonstration project, proton exchange membrane fuel cell systems have been installed at three residences to provide electrical power and waste heat for domestic hot water and space heating. The 5kW capacity fuel cells operate on reformed natural gas. These systems operate at preset levels providing power to the residence and to the utility grid. During grid outages, the residential power source is disconnected from the grid and the fuel cell system operates in standby mode to provide power to critical loads in the residence. This paper describes lessons learned from installation and operation of these fuel cell systems in existing residences. Issues associated with installation of a fuel cell system for combined heat and power focus primarily on fuel cell siting, plumbing external to the fuel cell unit required to support heat recovery, and line connections between the fuel cell unit and the home interior for natural gas, water, electricity, and communications. Operational considerations of the fuel cell system are linked to heat recovery system design and conditions required for adequate flow of natural gas, air, water, and system communications. Based on actual experience with these systems in a residential setting, proper system design, component installation, and sustainment of required flows are essential for the fuel cell system to provide reliable power and waste heat.


Sign in / Sign up

Export Citation Format

Share Document