Performance of a thermoelectric cooling system integrated with a gravity-assisted heat pipe for cooling electronics

2017 ◽  
Vol 116 ◽  
pp. 433-444 ◽  
Author(s):  
Xiaoqin Sun ◽  
Linfeng Zhang ◽  
Shuguang Liao
2017 ◽  
Vol 105 ◽  
pp. 4909-4914 ◽  
Author(s):  
Xiaoqin Sun ◽  
Yanjia Yang ◽  
Hongliang Zhang ◽  
Huiwei Si ◽  
Liang Huang ◽  
...  

Author(s):  
Hamidreza Behi ◽  
Danial Karimi ◽  
Foad Heidari Gandoman ◽  
Mohsen Akbarzadeh ◽  
Sahar Khaleghi ◽  
...  

2016 ◽  
Vol 196 (3) ◽  
pp. 598-613 ◽  
Author(s):  
Kyung Mo Kim ◽  
Yeong Shin Jeong ◽  
In Guk Kim ◽  
In Cheol Bang

Author(s):  
Seyyed Khandani ◽  
Himanshu Pokharna ◽  
Sridhar Machiroutu ◽  
Eric DiStefano

Remote heat pipe based heat exchanger cooling systems are becoming increasingly popular in cooling of notebook computers. In such cooling systems, one or more heat pipes transfer the heat from the more populated area to a location with sufficient space allowing the use of a heat exchanger for removal of the heat from the system. In analsysis of such systems, the temperature drop in the condenser section of the heat pipe is assumed negligible due to the nature of the condensation process. However, in testing of various systems, non linear longitudinal temperature drops in the heat pipe in the range of 2 to 15 °C, for different processor power and heat exchanger airflow, have been measured. Such temperature drops could cause higher condenser thermal resistance and result in lower overall heat exchanger performance. In fact the application of the conventional method of estimating the thermal performance, which does not consider such a nonlinear temperature variations, results in inaccurate design of the cooling system and requires unnecessarily higher safety factors to compensate for this inaccuracy. To address the problem, this paper offers a new analytical approach for modeling the heat pipe based heat exchanger performance under various operating conditions. The method can be used with any arbitrary condenser temperature variations. The results of the model show significant increase in heat exchanger thermal resistance when considering a non linear condenser temperature drop. The experimental data also verifies the result of the model with sufficient accuracy and therefore validates the application of this model in estimating the performance of these systems.   This paper was also originally published as part of the Proceedings of the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems.


2012 ◽  
Vol 25 (4) ◽  
pp. 566-574 ◽  
Author(s):  
Yunze LI ◽  
Mingmin LI ◽  
Kok Meng LEE

Sign in / Sign up

Export Citation Format

Share Document