Part load operation of natural gas fired power plant with CO2 capture system for selective exhaust gas recirculation

2021 ◽  
Vol 190 ◽  
pp. 116808
Author(s):  
Yamina Qureshi ◽  
Usman Ali ◽  
Farooq Sher
2019 ◽  
Vol 92 (2) ◽  
pp. 370-381 ◽  
Author(s):  
Agustín Moisés Alcaráz-Calderon ◽  
Maria Ortencia González-Díaz ◽  
Ángel Mendez ◽  
Jose Miguel González-Santaló ◽  
Abigail González-Díaz

Author(s):  
Maria Elena Diego ◽  
Jean-Michel Bellas ◽  
Mohamed Pourkashanian

Post-combustion CO2 capture from natural gas combined cycle (NGCC) power plants is challenging due to the large flow of flue gas with low CO2 content (∼3–4%vol.) that needs to be processed in the capture stage. A number of alternatives have been proposed to solve this issue and reduce the costs of the associated CO2 capture plant. This work focuses on the selective exhaust gas recirculation (S-EGR) configuration, which uses a membrane to selectively recirculate CO2 back to the inlet of the compressor of the turbine, thereby greatly increasing the CO2 content of the flue gas sent to the capture system. For this purpose, a parallel S-EGR NGCC system (53% S-EGR ratio) coupled to an amine capture plant using MEA 30%wt. was simulated using gCCS (gPROMS). It was benchmarked against an unabated NGCC system, a conventional NGCC coupled with an amine capture plant (NGCC+CCS), and an EGR NGCC power plant (39% EGR ratio) using amine scrubbing as the downstream capture technology. The results obtained indicate that the net power efficiency of the parallel S-EGR system can be up to 49.3% depending on the specific consumption of the auxiliary S-EGR systems, compared to the 49.0% and 49.8% values obtained for the NGCC+CCS and EGR systems, respectively. A preliminary economic study was also carried out to quantify the potential of the parallel S-EGR configuration. This high-level analysis shows that the cost of electricity for the parallel S-EGR system varies from 82.1–90.0 $/MWhe for the scenarios considered, with the cost of CO2 avoided being in the range of 79.7–105.1 $/tonne CO2. The results obtained indicate that there are potential advantages of the parallel S-EGR system in comparison to the NGCC+CCS configuration in some scenarios. However, further benefits with respect to the EGR configuration will depend on future advancements and cost reductions achieved on membrane-based systems.


Author(s):  
Maria Elena Diego ◽  
Jean-Michel Bellas ◽  
Mohamed Pourkashanian

Postcombustion CO2 capture from natural gas combined cycle (NGCC) power plants is challenging due to the large flow of flue gas with low CO2 content (∼3–4 vol %) that needs to be processed in the capture stage. A number of alternatives have been proposed to solve this issue and reduce the costs of the associated CO2 capture plant. This work focuses on the selective exhaust gas recirculation (S-EGR) configuration, which uses a membrane to selectively recirculate CO2 back to the inlet of the compressor of the turbine, thereby greatly increasing the CO2 content of the flue gas sent to the capture system. For this purpose, a parallel S-EGR NGCC system (53% S-EGR ratio) coupled to an amine capture plant (ACP) using monoethanolamine (MEA) 30 wt % was simulated using gCCS (gPROMS). It was benchmarked against an unabated NGCC system, a conventional NGCC coupled with an ACP (NGCC + carbon capture and storage (CCS)), and an EGR NGCC power plant (39% EGR ratio) using amine scrubbing as the downstream capture technology. The results obtained indicate that the net power efficiency of the parallel S-EGR system can be up to 49.3% depending on the specific consumption of the auxiliary S-EGR systems, compared to the 49.0% and 49.8% values obtained for the NGCC + CCS and EGR systems, respectively. A preliminary economic study was also carried out to quantify the potential of the parallel S-EGR configuration. This high-level analysis shows that the cost of electricity (COE) for the parallel S-EGR system varies from 82.1 to 90.0 $/MWhe for the scenarios considered, with the cost of CO2 avoided (COA) being in the range of 79.7–105.1 $/ton CO2. The results obtained indicate that there are potential advantages of the parallel S-EGR system in comparison to the NGCC + CCS configuration in some scenarios. However, further benefits with respect to the EGR configuration will depend on future advancements and cost reductions achieved on membrane-based systems.


2018 ◽  
Vol 549 ◽  
pp. 649-659 ◽  
Author(s):  
Giuseppe Russo ◽  
George Prpich ◽  
Edward J. Anthony ◽  
Fabio Montagnaro ◽  
Neila Jurado ◽  
...  