Determination of detection efficiency curves of HPGe detectors on radioactivity measurement of volume samples

2004 ◽  
Vol 61 (6) ◽  
pp. 1383-1390 ◽  
Author(s):  
Jun Saegusa ◽  
Katsuya Kawasaki ◽  
Akira Mihara ◽  
Mitsuo Ito ◽  
Makoto Yoshida
Author(s):  
Alojz Slaninka ◽  
Ondrej Sla´vik ◽  
Vladimi´r Necˇas

New free release monitoring post with a large volume 600 L container counting geometry was designed and developed. The monitoring system is able to monitor a material also in standard counting geometry of 200 L drum. Using counting geometry of 600 L rectangular container that is equipped with self-discharger is able to increase the total monitoring capacity. The monitoring system is based on a pair of electrically cooled semiconductor HPGe detectors that are placed into a modifiable vertical or horizontal pair of lead collimators. The monitoring system is integrated with an industrial scale for determination of massic activities of measured materials and in addition by a rotating table in the case of 200 L drums monitoring. Monitoring system is integrated into transportable ISO container with constant environmental conditions that are ensured by air-condition unit. Full-energy peak detection efficiency (FPE) polynomial curves for various densities of measured material were in both cases determined by ISOCS calibration code based on designed counting geometry and delivered ISOCS/LabSOCS detector characterization. Uncertainty analysis of massic activity measurement by container and drum monitoring system in designed counting geometry is introduced below in more detail.


2018 ◽  
Vol 2018 ◽  
pp. 1-8
Author(s):  
Jelena Krneta Nikolić ◽  
Milica Rajačić ◽  
Dragana Todorović ◽  
Marija Janković ◽  
Nataša Sarap ◽  
...  

One of the main problems in quantitative gamma-ray spectroscopy is the determination of detection efficiency, for different energies, source-detector geometries, and composition of samples or sources. There are, in principle, three approaches to this issue: experimental, numerical, and semiempirical. Semiempirical approach is based on the calculation of the efficiency for the measured sample on the basis of an experimental efficiency measured on the same detector, but with a calibration source that can be of different size, geometry, density, or composition—the so-called efficiency transfer. The aim of this paper is to analyze the semiempirical approach, using EFFTRAN and MEFFTRAN software as a typical example. These software were used in the Department of Radiation and Environmental Protection, Vinča Institute of Nuclear Sciences, on three HPGe detectors. The results were compared to the experimentally obtained efficiency, and further validation is performed by measuring reference materials issued within the framework of several interlaboratory intercomparisons. The analysis of the results showed that the efficiency transfer produces good results with the discrepancies within the limits of the measurement uncertainty. Also, for intercomparison measurement, utest criterion for the trueness of the result was applied showing that the majority of the obtained results were acceptable. Some difficulties were identified, and the ways to overcome them were discussed.


2020 ◽  
Vol 27 ◽  
pp. 106
Author(s):  
Sotirios Chasapoglou ◽  
A. Tsantiri ◽  
A. Kalamara ◽  
M. Kokkoris ◽  
V. Michalopoulou ◽  
...  

The accurate knowledge of neutron-induced fission cross sections in actinides, is of great importance when it comes to the design of fast nuclear reactors, as well as accelerator driven systems. Specifically for the 232Th(n,f) case, the existing experimental datasets are quite discrepant in both the low and high energy MeV regions, thus leading to poor evaluations, a fact that in turn implies the need for more accurate measurements.In the present work, the total cross section of the 232Th(n,f) reaction has been measured relative to the 235U(n,f) and 238U(n,f) ones, at incident energies of 7.2, 8.4, 9.9 MeV and 14.8, 16.5, 17.8 MeV utilizing the 2H(d,n) and 3H(d,n) reactions respectively, which generally yield quasi-monoenergetic neutron beams. The experiments were performed at the 5.5 MV Tandem accelerator laboratory of N.C.S.R. “Demokritos”, using a Micromegas detector assembly and an ultra thin ThO2 target, especially prepared for fission measurements at n_ToF, CERN during its first phase of operations, using the painting technique. The masses of all actinide samples were determined via α-spectroscopy. The produced fission yields along with the results obtained from activation foils were studied in parallel, using both the NeusDesc [1] and MCNP5 [2] codes, taking into consideration competing nuclear reactions (e.g. deuteron break up), along with neutron elastic and inelastic scattering with the beam line, detector housing and experimental hall materials. Since the 232Th(n,f) reaction has a relatively low energy threshold and can thus be affected by parasitic neutrons originating from a variety of sources, the thorough characterization of the neutron flux impinging on the targets is a prerequisite for accurate cross-section measurements, especially in the absence of time-of-flight capabilities. Additional Monte-Carlo simulations were also performed coupling both GEF [3] and FLUKA [4] codes for the determination of the detection efficiency.


2006 ◽  
Vol 41 (4) ◽  
pp. 272-278
Author(s):  
Naureen Mahbub RAHMAN ◽  
Takao IIDA ◽  
Hiromi YAMAZAWA ◽  
Jun MORIIZUMI

2006 ◽  
Vol 12 (5) ◽  
pp. 406-415 ◽  
Author(s):  
Marco Alvisi ◽  
Markus Blome ◽  
Michael Griepentrog ◽  
Vasile-Dan Hodoroaba ◽  
Peter Karduck ◽  
...  

A calibration procedure for the detection efficiency of energy dispersive X-ray spectrometers (EDS) used in combination with scanning electron microscopy (SEM) for standardless electron probe microanalysis (EPMA) is presented. The procedure is based on the comparison of X-ray spectra from a reference material (RM) measured with the EDS to be calibrated and a reference EDS. The RM is certified by the line intensities in the X-ray spectrum recorded with a reference EDS and by its composition. The calibration of the reference EDS is performed using synchrotron radiation at the radiometry laboratory of the Physikalisch-Technische Bundesanstalt. Measurement of RM spectra and comparison of the specified line intensities enables a rapid efficiency calibration on most SEMs. The article reports on studies to prepare such a RM and on EDS calibration and proposes a methodology that could be implemented in current spectrometer software to enable the calibration with a minimum of operator assistance.


Sign in / Sign up

Export Citation Format

Share Document