Miniaturized chromatographic systems for radiochemical purity evaluation of 131I-Ferulic acid as a new candidate in nuclear medicine applications

2021 ◽  
Vol 167 ◽  
pp. 109370
Author(s):  
Ghada A. Sedik ◽  
R.S. Abo Rizq ◽  
I.T. Ibrahim ◽  
E.S. Elzanfaly ◽  
M.A. Motaleb
2005 ◽  
Vol 48 (spe2) ◽  
pp. 1-8 ◽  
Author(s):  
Marisa de Jesus de C. Lima ◽  
Fabio Luiz Navarro Marques ◽  
Miriam Roseli Yoshie Okamoto ◽  
Alexandre Tales Garcez ◽  
Marcelo Tatit Sapienza ◽  
...  

The [Cu(MIBI)4]BF4 complex was synthesized and different formulations for lyophilized kits that could be cost-effectively used with different routines in nuclear medicine laboratories were investigated. In one preparation the kit components were kept similar to the Cardiolite® , except that the SnCl2.2H2O concentration was increased to 0.150 mg. In a second formulation, component concentrations were reduced to 1/5 of the original value and the SnCl2.2H2O concentration was adjusted to 0.04 mg. These products were labeled with maximum activities of 55.5 GBq and 8.14 GBq, respectively, and have shown an average radiochemical purity of 95 %. Biodistribution of the products was assessed by dissection in mice and in rabbits, and did not show any statistical difference when compared to Cardiolite®. In the synthesis of [Cu(MIBI)4]BF4 a new procedure was introduced for the synthesis of N-(2-methyl-propenyl)-formamide, with the use of microwave radiation as heat source. This modification reduced the reaction time to 25 seconds, while maintaining a yield of 68%.


Anales AFA ◽  
2021 ◽  
Vol 32 (3) ◽  
pp. 72-75
Author(s):  
N. Guisande ◽  
◽  
J. Sanchez ◽  
L. Garavaglia ◽  
S. Rozanskas ◽  
...  

This work analyzes the reliability of the radiochemical purity control method of99mTc-MIBI used in nuclear medicine services and the influence of the greater presence of radiochemical impurities in the diagnostic quality of the obtained images.


1990 ◽  
Vol 137 (3) ◽  
pp. 163 ◽  
Author(s):  
V.A. Oliveira ◽  
J.M. Nightingale

2020 ◽  
Vol 59 (04) ◽  
pp. 294-299 ◽  
Author(s):  
Lutz S. Freudenberg ◽  
Ulf Dittmer ◽  
Ken Herrmann

Abstract Introduction Preparations of health systems to accommodate large number of severely ill COVID-19 patients in March/April 2020 has a significant impact on nuclear medicine departments. Materials and Methods A web-based questionnaire was designed to differentiate the impact of the pandemic on inpatient and outpatient nuclear medicine operations and on public versus private health systems, respectively. Questions were addressing the following issues: impact on nuclear medicine diagnostics and therapy, use of recommendations, personal protective equipment, and organizational adaptations. The survey was available for 6 days and closed on April 20, 2020. Results 113 complete responses were recorded. Nearly all participants (97 %) report a decline of nuclear medicine diagnostic procedures. The mean reduction in the last three weeks for PET/CT, scintigraphies of bone, myocardium, lung thyroid, sentinel lymph-node are –14.4 %, –47.2 %, –47.5 %, –40.7 %, –58.4 %, and –25.2 % respectively. Furthermore, 76 % of the participants report a reduction in therapies especially for benign thyroid disease (-41.8 %) and radiosynoviorthesis (–53.8 %) while tumor therapies remained mainly stable. 48 % of the participants report a shortage of personal protective equipment. Conclusions Nuclear medicine services are notably reduced 3 weeks after the SARS-CoV-2 pandemic reached Germany, Austria and Switzerland on a large scale. We must be aware that the current crisis will also have a significant economic impact on the healthcare system. As the survey cannot adapt to daily dynamic changes in priorities, it serves as a first snapshot requiring follow-up studies and comparisons with other countries and regions.


1981 ◽  
Vol 20 (06) ◽  
pp. 279-282 ◽  
Author(s):  
D. Konstantinovska ◽  
K. Milivojević ◽  
J. Bzenić ◽  
V. Jovanović

Labelling yield and radiochemical purity, higher than 95%, of 99mTc-colloid preparations were determined by using the paper chromatography method. Less than 3% of labelled citric acid, added to the preparation as a buffer solution, has been found in 99mTc-sulphur colloid. High radiochemical purity and optimum size of colloid particles has also been proved by biodistribution studies on experimental animals. The analysis performed has shown that more than 50% of 99mTc-colloid preparations excreted by urine is 99mTcO–, the remaining past 50% being protein bound 99mTc. Biological half-time of excretion of the fast phase is the same for both preparations, i.e. 10 min, while for the slow component it is 120 min in 99mTc-S-colloid and 160 min in 99mTc-Sn colloid.


1978 ◽  
Vol 17 (03) ◽  
pp. 110-125 ◽  
Author(s):  
O.P.D Noronha

A review is made of some of the factors affecting bioavailability of diagnostic 99mTc-radiopharmaceuticals currently used in the practice of nuclear medicine.


2007 ◽  
Vol 46 (02) ◽  
pp. 49-55 ◽  
Author(s):  
W. Burchert ◽  
F. M. Bengel ◽  
R. Zimmermann ◽  
J. vom Dahl ◽  
W. Schäfer ◽  
...  

SummaryThe working group Cardiovascular Nuclear Medicine of the German Society of Nuclear Medicine (DGN), in cooperation with the working group Nuclear Cardiology of the German Cardiac Society (DGK), decided to conduct a national survey on myocardial perfusion scintigraphy (MPS). Method: A questionnaire to evaluate MPS for the year 2005 was sent. Results: 346 completed questionnaires had been returned (213 private practices, 99 hospitals and 33 university hospitals). MPS of 112 707 patients were reported with 110 747 stress and 95 878 rest studies. The majority (>75%) was performed with 99mTc-MIBI or tetrofosmin. 201Tl stress-redistribution was used in 22 637 patients (20%). The types of stress were exercise in 78%, vasodilation with adenosine or dipyridamol in 21% and dobutamine in 1%. 99.97% of all MPS were SPECT studies. Gated SPECT was performed in 36% of the stress and in 32% of the rest studies. An attenuation correction was used in 21%. 29 institutions (8%) performed gated SPECT (stress and rest) and attenuation correction. 47% of all MPS were requested by ambulatory care cardiologists, 17% by internists, 12% by primary care physicians, 21% by hospital departments and 2% by others. Conclusion: In Germany, MPS is predominantly performed with 99mTc-perfusion agents. The common type of stress is ergometry. Gated SPECT and attenuation correction do not yet represent standards of MPS practice in Germany, which indicates some potential of optimization.


1982 ◽  
Vol 21 (03) ◽  
pp. 85-91 ◽  
Author(s):  
R. Poppitz

Um die Strahlenexposition und das Strahlenrisiko für die Bevölkerung durch die nuklearmedizinische Diagnostik in Bulgarien zu ermitteln, wurde eine Erhebung für das Jahr 1980 über die Arten und Anzahl der Applikationen von Radiopharmaka, über die verwendeten Aktivitäten und über die Geschlechts- und Altersverteilung der untersuchten Patienten durchgeführt. Die Gesamtzahl diagnostischer in vivo Applikationen betrug 116418 (davon 40,5% bei Männern und 59,5% bei Frauen), d.h. 13,1 Applikationen per 1000 Einwohner. Die applizierte Gesamtaktivität aller 44 verwendeter Radiopharmaka betrug ca. 2,1 TBq (56 Ci). Die Geschlechts- und Altersverteilung der untersuchten Patienten war ähnlich jener in anderen Ländern: nur 17,4% aller Patienten waren im reproduktionsfähigen Alter, 52,7% waren über 45 Jahre alt. Im Vergleich zu anderen entwickelten Ländern war in Bulgarien im Jahr 1980 der Anteil der 131J-Jodid-Untersuchungen verhältnismäßig hoch.


Sign in / Sign up

Export Citation Format

Share Document