radiochemical purity
Recently Published Documents


TOTAL DOCUMENTS

382
(FIVE YEARS 105)

H-INDEX

14
(FIVE YEARS 3)

Molecules ◽  
2022 ◽  
Vol 27 (2) ◽  
pp. 543
Author(s):  
Silvia Migliari ◽  
Antonino Sammartano ◽  
Marti Boss ◽  
Martin Gotthardt ◽  
Maura Scarlattei ◽  
...  

Background: Glucagon-like peptide 1 receptor (GLP-1R) is preferentially expressed in pancreatic islets, especially in β-cells, and highly expressed in human insulinomas and gastrinomas. In recent years several GLP-1R–avid radioligands have been developed to image insulin-secreting tumors or to provide a tentative quantitative in vivo biomarker of pancreatic β-cell mass. Exendin-4, a 39-amino acid peptide with high binding affinity to GLP-1R, has been labeled with Ga-68 for imaging with positron emission tomography (PET). Preparation conditions may influence the quality and in vivo behavior of tracers. Starting from a published synthesis and quality controls (QCs) procedure, we have developed and validated a new rapid and simple UV-Radio-HPLC method to test the chemical and radiochemical purity of [68Ga]Ga-NODAGA-exendin-4, to be used in the clinical routine. Methods: Ga-68 was obtained from a 68Ge/68Ga Generator (GalliaPharma®) and purified using a cationic-exchange cartridge on an automated synthesis module (Scintomics GRP®). NODAGA-exendin-4 contained in the reactor (10 µg) was reconstituted with HEPES and ascorbic acid. The reaction mixture was incubated at 100 °C. The product was purified through HLB cartridge, diluted, and sterilized. To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document released by the International Conference on Harmonization of Technical Requirements of Pharmaceuticals for Human Use (ICH), adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. Therefore, a range of concentrations of Ga-NODAGA-exendin-4, NODAGA-exendin-4 (5, 4, 3.125, 1.25, 1, and 0.75 μg/mL) and [68Ga]Ga-NODAGA-exendin-4 were analyzed. To validate the entire production process, three consecutive batches of [68Ga]Ga-NODAGA-exendin-4 were tested. Results: Excellent linearity was found between 5–0.75 μg/mL for both the analytes (NODAGA-exendin-4 and 68Ga-NODAGA-exendin-4), with a correlation coefficient (R2) for calibration curves equal to 0.999, average coefficients of variation (CV%) <2% (0.45% and 0.39%) and average per cent deviation value of bias from 100%, of 0.06% and 0.04%, respectively. The calibration curve for the determination of [68Ga]Ga-NODAGA-exendin-4 was linear with a R2 of 0.993 and CV% <2% (1.97%), in accordance to acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed using 10 μg of peptide. The mean radiochemical yield was 45 ± 2.4% in all the three validation batches of [68Ga]Ga-NODAGA-exendin-4. The radiochemical purity of [68Ga]Ga-NODAGA-exendin-4 was >95% (97.05%, 95.75% and 96.15%) in all the three batches. Conclusions: The developed UV-Radio-HPLC method to assess the radiochemical and chemical purity of [68Ga]Ga-NODAGA-exendin-4 is rapid, accurate and reproducible like its fully automated production. It allows the routine use of this PET tracer as a diagnostic tool for PET imaging of GLP-1R expression in vivo, ensuring patient safety.


2022 ◽  
Author(s):  
Tomoteru Yamasaki ◽  
Katsushi Kumata ◽  
Atsuto Hiraishi ◽  
Yiding Zhang ◽  
Hidekatsu Wakizaka ◽  
...  

Abstract Background: Receptor-interacting protein 1 kinase (RIPK1) is a key enzyme in the regulation of cellular necroptosis. Recently, cyclohexyl (5-(2-acetamidobenzo[d]thiazol-6-yl)-2-methylpyridin-3-yl)carbamate (PK68, 5) has been developed as a potent inhibitor of RIPK1. Herein, we radiosynthesized [11C]PK68 as a new positron emission tomography (PET) ligand for imaging RIPK1 and evaluated its potential in vivo.Results: We synthesized [11C]PK68 by reacting amine precursor 14 with [11C]acetyl chloride. At the end of synthesis, we obtained [11C]PK68 of 1200–1790 MBq (n = 10) with >99% radiochemical purity and a molar activity of 37–99 GBq/μmol starting from 18–33 GBq of [11C]CO2. The fully automated synthesis took 30 min from the end of irradiation. In a small-animal PET study, [11C]PK68 was rapidly distributed in the liver and kidneys of healthy mice after injection, and was subsequently cleared from their bodies via hepatobiliary excretion and the intestinal reuptake pathway. Although there was no obvious specific binding of RIPK1 in the PET study, [11C]PK68 demonstrated relatively high stability in vivo, and may be used as a lead compound for further candidate development.Conclusions: In the present study, we successfully radiosynthesized [11C]PK68 and evaluated its potential in vivo. We are planning to optimize the chemical structure of [11C]PK68 and conduct further PET studies on it using pathological models.


2021 ◽  
Vol 6 (1) ◽  
Author(s):  
James M. Kelly ◽  
Alejandro Amor-Coarasa ◽  
Elizabeth Sweeney ◽  
Justin J. Wilson ◽  
Patrick W. Causey ◽  
...  

Abstract Background As 225Ac-labeled radiopharmaceuticals continue to show promise as targeted alpha therapeutics, there is a growing need to standardize quality control (QC) testing procedures. The determination of radiochemical purity (RCP) is an essential QC test. A significant obstacle to RCP testing is the disruption of the secular equilibrium between actinium-225 and its daughter radionuclides during labeling and QC testing. In order to accelerate translation of actinium-225 targeted alpha therapy, we aimed to determine the earliest time point at which the RCP of an 225Ac-labeled radiopharmaceutical can be accurately quantified. Results Six ligands were conjugated to macrocyclic metal chelators and labeled with actinium-225 under conditions designed to generate diverse incorporation yields. RCP was determined by radio thin layer chromatography (radioTLC) followed by exposure of the TLC plate on a phosphor screen either 0.5, 2, 3.5, 5, 6.5, or 26 h after the plate was developed. The dataset was used to create models for predicting the true RCP for any pre-equilibrium measurement taken at an early time point. The 585 TLC measurements span RCP values of 1.8–99.5%. The statistical model created from these data predicted an independent data set with high accuracy. Predictions made at 0.5 h are more uncertain than predictions made at later time points. This is primarily due to the decay of bismuth-213. A measurement of RCP > 90% at 2 h predicts a true RCP > 97% and guarantees that RCP will exceed 90% after secular equilibrium is reached. These findings were independently validated using NaI(Tl) scintillation counting and high resolution gamma spectroscopy on a smaller set of samples with 10% ≤ RCP ≤ 100%. Conclusions RCP of 225Ac-labeled radiopharmaceuticals can be quantified with acceptable accuracy at least 2 h after radioTLC using various methods of quantifying particle emissions. This time point best balances the need to accurately quantify RCP with the need to safely release the batch as quickly as possible.


2021 ◽  
Vol 15 ◽  
Author(s):  
Fanxing Zeng ◽  
Jonathon A. Nye ◽  
Ronald J. Voll ◽  
Jiyoung Mun ◽  
Mark M. Goodman

The serotonin 5-HT2C receptor (5-HT2CR) is abundantly expressed throughout the central nervous system, and involved in a variety of neuroendocrine and neurobehavioral processes. The development of a selective radioligand that will enable in vivo imaging and quantification of 5-HT2CR densities represents a significant technological advancement in understanding both the normal function and pathophysiology of the 5-HT2CR. Four 7-halogen-2-phenyl isoindolones (7-F, Cl, Br, I) were synthesized and displayed high affinities for 5-HT2CR and high selectivity over 5-HT2A and 5-HT2B. [11C]7-Chloro-2-[4-methoxy-3-[2-(4-methylpiperidin-1-yl)ethoxy]phenyl]isoindolin-1-one (6) and [11C]7-iodo-2-[4-methoxy-3-[2-(4-methylpiperidin-1-yl)ethoxy]phenyl]isoindolin-1-one (9) were synthesized in high radiochemical yield of 37–44% [n = 10, decay corrected from end of (11C)CH3I synthesis] with high radiochemical purity via O-methylation with [11C]CH3I, respectively. MicroPET imaging studies in male rats with or without 5-HT2C antagonist SB-242084 showed that [11C]6 and [11C]9 display specific bindings to 5-HT2CR in the choroid plexus and hippocampus. In vivo microPET brain imaging studies in rhesus monkeys demonstrated that [11C]6 and [11C]9 exhibit excellent blood-brain barrier penetration. The contrast of bindings to the choroid plexus and hippocampus compared to the cerebellum peaked at 2.7 and 1.6, respectively, for [11C]6, and 3.7 and 2.7, respectively, for [11C]9, which were reduced by administration of a dose of SB-242084. Our results support the candidacy of [11C]6 and [11C]9 for further study as radioligands for in vivo quantitation of 5-HT2C sites by PET.


2021 ◽  
Vol 1 ◽  
Author(s):  
Anton Lindberg ◽  
Amanda J. Boyle ◽  
Junchao Tong ◽  
Michael B. Harkness ◽  
Armando Garcia ◽  
...  

Ibrutinib is a first-generation Bruton's tyrosine kinase (BTK) inhibitor that has shown efficacy in autoimmune diseases and has consequently been developed as a positron emission tomography (PET) radiotracer. Herein, we report the automated radiosynthesis of [11C]ibrutinib through 11C-carbonylation of the acrylamide functional group, by reaction of the secondary amine precursor with [11C]CO, iodoethylene, and palladium–NiXantphos. [11C]Ibrutinib was reliably formulated in radiochemical yields of 5.4% ± 2.5% (non-decay corrected; n = 9, relative to starting [11C]CO2), radiochemical purity &gt;99%, and molar activity of 58.8 ± 30.8 GBq/μmol (1.55 ± 0.83 Ci/μmol). Preliminary PET/magnetic resonance imaging with [11C]ibrutinib in experimental autoimmune encephalomyelitis (EAE) mice showed a 49% higher radioactivity accumulation in the spinal cord of mice with EAE scores of 2.5 vs. sham mice.


2021 ◽  
Author(s):  
Danni Ramdhani ◽  
Maula Eka Sriy ◽  
Eva Maria W ◽  
Nita Listiani ◽  
Resmi Mustarichie ◽  
...  

Abstract Objective. Selective estrogen receptor modulators (SERMs) have been widely used to treat breast cancer, osteoporosis, and postmenopausal symptoms. SERMs have an affinity for estrogen receptors (ER) in target tissues and resist stimulation of the breast, bone, and endometrium. Genistein as an isoflavone compound that has a high affinity for ERβ targets makes it a potential target or prognostic marker for breast cancer. This study was carried out to develop 99mTc-genistein kit that can be used to detect breast cancer. Methods. The synthesis process and quality control were investigated to obtain the optimal formula for the ratio of a substance, reducing agent, optimal conditions of the synthesis reaction, physicochemical properties of the kit, and its stability to meet the requirements of radiochemical purity. Results. The radiochemical purity in the development of the radiopharmaceutical kit was 93.25% ± 0.30%. The physicochemical properties of the kit preparations showed hydrophilic properties, good plasma protein binding, no electrical charge, and were stable at storage temperatures. Conclusions. The radiochemical purity of the radiopharmaceutical kits meets the requirements of the United State Pharmacopeia and has good physicochemical properties to be developed into kits.


2021 ◽  
Vol 6 (1) ◽  
Author(s):  
Costantina Maisto ◽  
Anna Morisco ◽  
Roberta de Marino ◽  
Elisabetta Squame ◽  
Valentina Porfidia ◽  
...  

Abstract Background Prostate-specific membrane antigen is overexpressed in prostate cancer and it is considered a good target for positron emission tomography/computed tomography imaging of primary cancer and recurrent/metastatic disease, as well as for radioligand therapy. Different PSMA-analogues labeled with [68Ga]gallium have been investigated, showing excellent imaging properties; however, only small amounts can be produced for each radiolabeling. Recently, a [18F]fluoride labeled PSMA-inhibitor, [18F]PSMA-1007, has been introduced, and it has ensured large-scale productions, overcoming this limitation of [68Ga]PSMAs. In this study, PSMA-1007 has been labeled with low (A), medium (B) and high (C) starting activities of [18F]fluoride, in order to verify if radiochemical yield, radiochemical purity and stability of [18F]PSMA-1007 were affected. These parameters have been measured in sixty-five consecutive batches. In addition, the estimation of [18F]PSMA-1007 production costs is provided. Results The radiochemical yield for low and medium activities of [18F]fluoride was 52%, while for the high one it decreased to 40%. The radiochemical purity was 99% for all three activities. [18F]PSMA-1007 did not show radiolysis up to 8 h after the end of synthesis, confirming that the radiopharmaceutical is stable and suitable to perform diagnostic studies in humans for a long period of time after the end of radiolabeling. Furthermore, radiochemical stability was demonstrated in fetal bovine serum at 4 °C and 37 °C for 120′. Conclusions A starting activity of [18F]fluoride of 90 GBq (B) seems to be the best option enabling a final amount of about of 50 GBq of [18F]PSMA-1007, which is promising as it allows to: (a) perform a large number of scans, and/or (b) supply the radiopharmaceutical to any peripheral diagnostic centers in need.


2021 ◽  
Vol 6 (1) ◽  
Author(s):  
Ruslan Cusnir ◽  
Michel Leresche ◽  
Claude Pilloud ◽  
Marietta Straub

Abstract Background Nanocolloidal human serum albumin radiolabelled with 99mTc provides a diagnostic radiopharmaceutical for sentinel node lymphoscintigraphy. NanoHSA (Nanotop), a commercially available kit, enables the simple preparation of this radiopharmaceutical via reconstitution with pertechnetate eluted from a generator. Thin-layer chromatography is widely used for determining radiochemical purity in clinical nuclear medicine. Quality control methods recommended by the manufacturer were sometimes reported to yield variable results. Therefore, we proposed and evaluated three alternative thin-layer chromatography methods for the quality control of [99mTc]Tc-NanoHSA from a commercially available kit. Results The radiochemical purity of [99mTc]Tc-NanoHSA determined with all methods was reproducible and met the requirements of the SPC and the European Pharmacopoeia (≥ 95%). Our quality control using iTLC-SG chromatographic paper in methyl ethyl ketone mobile phase identified only free pertechnetate as impurity, resulting in > 99% RCP. The quality control using iTLC-SG in 85% methanol or iTLC-SA in 0.9% NaCl identified an additional small fraction of a hydrophilic impurity, resulting in 95–97% RCP. Glucose was identified as a potential 99mTc-carrying hydrophilic species contributing to hydrophilic impurities. Conclusion Our quality control of [99mTc]Tc-NanoHSA with non-polar mobile phase tended to underestimate the amount of hydrophilic impurities, although without compromising the final quality of the radiopharmaceutical. Alternative TLC methods using aqueous mobile phases enabled a more accurate determination of hydrophilic impurities.


Pharmaceutics ◽  
2021 ◽  
Vol 13 (9) ◽  
pp. 1326
Author(s):  
Janine Suthiram ◽  
Thomas Ebenhan ◽  
Biljana Marjanovic-Painter ◽  
Mike M. Sathekge ◽  
Jan Rijn Zeevaart

Substance P (SP) is a small peptide commonly known as a preferential endogenous ligand for the transmembrane neurokinin-1 receptor. Nuclear Medicine procedures currently involve radiolabeled SP derivatives in peptide radioligand endotherapy of inoperable glioblastoma. Promising clinical results sparked the demand for facile production strategies for a functionalized 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-[Thi8, Met(O2)11]-SP to allow for rapid Gallium-68 or Bismuth-213 complexation. Therefore, we provide a simple kit-like radiotracer preparation method that caters for the gallium-68 activity eluted from a SnO2 generator matrix as well as preliminary results on the adaptability to produce [213Bi]Bi-DOTA-[Thi8, Met(O2)11]SP from the same vials containing the same starting material. Following a phase of radioanalysis for complexation of gallium-68 to DOTA-[Thi8, Met(O2)11]SP and assessing the radiolabeling parameters, the vials containing appropriate kit-prototype material were produced in freeze-dried batches. The facile radiolabeling performance was tested and parameters for future human application were calculated to meet the criteria for theranostic loco-regional co-administration of activity doses comprising [68Ga]Ga-DOTA-[Thi8, Met(O2)11]SP mixed with [213Bi]Bi-DOTA-[Thi8, Met(O2)11]SP. [68Ga]Ga-DOTA-[Thi8, Met(O2)11]SP was prepared quantitatively from lyophilized starting material within 25 min providing the required molar activity (18 ± 4 GBq/µmol) and activity concentration (98 ± 24 MBq/mL), radiochemical purity (>95%) and sustained radiolabeling performance (4 months at >95% LE) as well as acceptable product quality (>95% for 120 min). Additionally, vials of the same starting materials were successfully adapted to a labeling strategy available for preparation of [213Bi]Bi-DOTA-[Thi8, Met(O2)11]SP providing sufficient activity for 1–2 human doses. The resultant formulation of [68Ga]Ga-/[213Bi]Bi-DOTA-[Thi8, Met(O2)11]SP activity doses was considered of adequate radiochemical quality for administration. This investigation proposes a simple kit-like formulation of DOTA-[Thi8, Met(O2)11]SP—a first-line investigation into a user friendly, straightforward tracer preparation that would warrant efficient clinical investigations in the future. Quantitative radiolabeling was accomplished for [68Ga]Ga-DOTA-[Thi8, Met(O2)11]SP and [213Bi]Bi-DOTA-[Thi8, Met(O2)11]SP preparations; a key requirement when addressing the specific route of catheter-assisted co-injection directly into the intratumoral cavities.


2021 ◽  
Vol 6 (1) ◽  
Author(s):  
Sadahiro Naka ◽  
Tadashi Watabe ◽  
Thomas Lindner ◽  
Jens Cardinale ◽  
Kenta Kurimoto ◽  
...  

Abstract Background Fibroblast activation protein (FAP) is overexpressed in the stroma of many types of cancer. [18F]AlF-FAPI-74 is a positron emission tomography tracer with high selectivity for FAP, which has already shown high accumulation within human tumors in clinical studies. However, [18F]AlF-FAPI-74 radiosynthesis has not been optimized using an automated synthesizer. Herein, we report a one-pot and one-step automated radiosynthesis method using a multi purpose synthesizer. Results Radiosynthesis of [18F]AlF-FAPI-74 was performed using a cassette-type multi purpose synthesizer CFN-MPS200. After the recovery rate of trapped [18F]fluoride onto the anion-exchange cartridge using a small amount of eluent was investigated manually, a dedicated [18F]AlF-FAPI-74 synthesis cassette and synthesis program for one-pot and one-step fluorination was developed. The solutions for the formulation of [18F]AlF-FAPI-74 synthesized using this were evaluated to obtain stable radiochemical purity. The recovery rate of [18F]fluoride with only 300 µL of eluent ranged 90 ± 9% by introduction from the male side and elution from the female side of the cartridge. In automated synthesis, the eluted [18F]fluoride and precursor solution containing aluminum chloride were mixed; then, fluorination was performed in a one-pot and one-step process at room temperature for 5 min, followed by 15 min at 95 °C. As a result, the radioactivity of [18F]AlF-FAPI-74 was 11.3 ± 1.1 GBq at the end of synthesis from 32 to 40 GBq of [18F]fluoride, and its radiochemical yield was 37 ± 4% (n = 10). The radiochemical purity at the end of the synthesis was ≥ 97% for all formulation solutions. When the diluent was saline, the radiochemical purity markedly decreased after 4 h of synthesis. In contrast, with phosphate-buffered saline (pH 7.4) or 10 mM phosphate-buffered saline (pH 6.7) containing 100 mg of sodium ascorbate, the radiochemical purity was stable at 97%. Non-radioactive AlF-FAPI-74 and total impurities, including non-radioactive AlF-FAPI-74, were 0.3 ± 0.1 µg/mL and 2.8 ± 0.6 µg/mL. Ethanol concentration and residual DMSO were 5.5 ± 0.2% and 21 ± 6 ppm, respectively. Conclusions We established a one-pot one-step automated synthesis method using a CFN-MPS200 synthesizer that provided high radioactivity and stable radiochemical purity for possible clinical applications.


Sign in / Sign up

Export Citation Format

Share Document