Improving the flame retardance of hydrophobic silica aerogels through a facile post-doping of magnesium hydroxide

Author(s):  
Yan Zhang ◽  
Liling Wu ◽  
Xi Deng ◽  
Yunmeng Deng ◽  
Xiaoxu Wu ◽  
...  
2013 ◽  
Vol 73 ◽  
pp. 28-33 ◽  
Author(s):  
Gamze Eris ◽  
Deniz Sanli ◽  
Zeynep Ulker ◽  
Selmi Erim Bozbag ◽  
Alexandr Jonás ◽  
...  

2019 ◽  
Vol 93 (1) ◽  
pp. 111-122 ◽  
Author(s):  
Yinfeng Wang ◽  
Zhi Li ◽  
Lukas Huber ◽  
Xiaoxu Wu ◽  
Siqi Huang ◽  
...  

2018 ◽  
Vol 5 (4) ◽  
pp. 045101 ◽  
Author(s):  
Xingqun Zhu ◽  
Hina Naz ◽  
Rai Nauman Ali ◽  
Yongfei Yang ◽  
Zhou Zheng ◽  
...  

2016 ◽  
Vol 437 ◽  
pp. 26-33 ◽  
Author(s):  
Yannan Duan ◽  
Sadhan C. Jana ◽  
Bimala Lama ◽  
Matthew P. Espe

2013 ◽  
Vol 235 ◽  
pp. 975-982 ◽  
Author(s):  
Ding Wang ◽  
Robert Pfeffer

2020 ◽  
Vol 12 (2) ◽  
pp. 206-211
Author(s):  
Supattra Eangpayung ◽  
Supan Yodyingyong ◽  
Darapond Triampo

Silica aerogel, the most common type of aerogels, comprised of 95% air in its structure which made the aerogel has a high surface area, high porosity, low density, and low thermal conductivity. Because of its structure and high porosity, one of its major weakness compared to other materials is being very brittle. This study aims at strengthening the connection points between silica nanoparticles using Pluronic10R5 (poly(propylene oxide)8–poly(ethylene oxide)22–poly(propylene oxide)8) where the Pluronic10R5 was used to reduce phase separation during the silica condensation reaction in the sol–gel process. Silica aerogel monoliths were prepared via a sol–gel process from hydrophobic silica gels and Pluronic10R5 with an ambient pressure drying (APD) process. Results from the compression test showed that the Pluronic10R5/silica aerogels have improved mechanical property by ten times that of unmodified silica aerogels. A thermogravimetric analysis (TGA) showed a mass loss at 300–400 °C that is attributed to the surface methyl group, while a mass loss at 200 °C refers to the loss of Pluronic10R5 which confirms the incorporation of Pluronic10R5 into the monolith. Moreover, infrared (IR) images revealed that the top surface temperature of Pluronic10R5/silica aerogels monolith is about 80 °C differs from the bottom heat source temperature of 160 °C.


2015 ◽  
Vol 27 (19) ◽  
pp. 6737-6745 ◽  
Author(s):  
Wim J. Malfait ◽  
Shanyu Zhao ◽  
Rene Verel ◽  
Subramaniam Iswar ◽  
Daniel Rentsch ◽  
...  

2012 ◽  
Vol 99 ◽  
pp. 28-35 ◽  
Author(s):  
Ding Wang ◽  
Elisabeth McLaughlin ◽  
Robert Pfeffer ◽  
Y.S. Lin

Sign in / Sign up

Export Citation Format

Share Document