Long Term Results With the Interlocking Uncemented Long Stem in Revision Hip Arthroplasty: A Mean 15-Year Follow-Up

2015 ◽  
Vol 30 (5) ◽  
pp. 835-839 ◽  
Author(s):  
Tomomi Kamada ◽  
Hiroshi Imai ◽  
Naohiko Mashima ◽  
Jun Takeba ◽  
Hideo Okumura ◽  
...  
2018 ◽  
Vol 28 (2) ◽  
pp. 133-138 ◽  
Author(s):  
Yeong J. Lau ◽  
Shashank Sarmah ◽  
Johan D. Witt

Introduction: 3rd generation ceramic bearings were introduced in total hip arthroplasty (THA) with the potential to have better mechanical strength and wear properties than their predecessors. At present, there are few studies looking at the long-term results of this latest generation of ceramic bearings. The purpose of our study was to investigate the long-term clinical and radiographic results of 3rd generation ceramic-on-ceramic THA and the incidence of ceramic specific complications such as squeaking and bearing surface fracture. Methods: The database of the senior author (J.D.W.) was reviewed. A total of 126 hip replacements performed in 108 patients (average age 39.6 years) with an average follow-up of 12.1 years (10-16 years) was identified. Clinical notes and plain radiographs were reviewed. To measure function, patients were contacted and an Oxford Hip Questionnaire was completed. Patients were also directly questioned about the presence of squeaking or any other sounds from the hip. Radiographs were evaluated for signs of wear, osteolysis, loosening and heterotopic ossification. The abduction angle of the acetabular component was measured. Results: The average Oxford Hip Score was 39.8 out of 48. Survivorship at 10 years was 94.6% (95% CI) with revision for any cause as the endpoint. There was 1 femoral head fracture, no osteolysis, no squeaking and no detectable wear. Conclusions: The good clinical and radiographic results for this series of patients are similar to other recent long-term studies looking at 3rd generation ceramic-on-ceramic THA. The results compare favourably with other bearing surfaces. The lack of osteolysis associated with this articulation is encouraging and may also make it a good choice for younger patients requiring total hip replacement.


2020 ◽  
Author(s):  
Kai Zheng ◽  
Ning Li ◽  
Weicheng Zhang ◽  
Jun Zhou ◽  
Yaozeng Xu ◽  
...  

Abstract Background: Revision total hip arthroplasty is frequently accompanied by bone loss. The purpose of this study is to evaluate mid- to long-term results of revision total hip arthroplasty for massive femoral bone loss using cementless modular, fluted, tapered stems.Methods: During the period of 2007 to 2015 at a single hospital, 34 hips (33 patients) underwent primary revision surgery with cementless modular, fluted, tapered stems due to massive bone loss, and patients with prosthetic joint infection (PJI) or tumours were excluded. The hips were revised with the LINK MP (Waldemar Link, Hamburg, Germany) prosthesis. Bone loss was categorized by the Paprosky classification for prosthesis loosening and Vancouver classification for peri-prosthetic fracture. All revision bearing surfaces were ceramic-on-ceramic (CoC). Clinical outcomes, radiographic outcomes and survivorship were evaluated.Results: The mean follow-up was 9.1±2.5 years (range, 5-13 years). The Harris hip score was 43.6±11.5 preoperatively and maintained at 86.5±6.6 at the time of latest follow-up (p<0. 05). The X-ray showed bone ingrowth fixation in 30 hips (88%), fibrous stable fixation in 3 hips (9%) and instability in 1 hip (3%). The average stem subsidence was 3.9±2.2 mm (range, 1 to 10 mm). The survivorship of prostheses with re-revision for any reason was 95% (95% CI, 12.0 to 13.0) at the 10-year follow-up. Three (9%) re-revisions were needed, including 1 for aseptic loosening, 1 for dislocation and 1 for infection.Conclusions: The mid- to long-term results of revision total hip arthroplasty with the cementless modular, fluted, tapered stem (LINK MP stem) are encouraging for massive femoral bone loss.


2019 ◽  
Vol 101-B (6_Supple_B) ◽  
pp. 123-126 ◽  
Author(s):  
M. El-Husseiny ◽  
B. Masri ◽  
C. Duncan ◽  
D. S. Garbuz

AimsWe investigated the long-term performance of the Tripolar Trident acetabular component used for recurrent dislocation in revision total hip arthroplasty. We assessed: 1) rate of re-dislocation; 2) incidence of complications requiring re-operation; and 3) Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain and functional scores.Patients and MethodsWe retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1994 and 2008. All patients had undergone revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 after more than three revisions. A total of 75 hips (73 patients) were treated with Tripolar liners due to recurrent instability with abductor deficiency, In addition, six patients had associated cerebral palsy, four had poliomyelitis, two had multiple sclerosis, two had spina bifida, two had spondyloepiphyseal dysplasia, one had previous reversal of an arthrodesis, and 21 had proximal femoral replacements. The mean age of patients at time of Tripolar insertions was 72 years (53 to 89); there were 69 female patients (two bilateral) and 42 male patients. All patients were followed up for a mean of 15 years (10 to 24). Overall, 55 patients (57 hips) died between April 2011 and February 2018, at a mean of 167 months (122 to 217) following their tripolar liner implantation. We extracted demographics, implant data, rate of dislocations, and incidence of other complications.ResultsAt ten years, the Kaplan–Meier survivorship for dislocation was 95.6% (95% confidence interval (CI) 90 to 98), with 101 patients at risk. At 20 years, the survivorship for dislocation was 90.6% (95% CI 81.0 to 95.5), with one patient at risk. Eight patients (7.2%) had a dislocation of their constrained liners. At ten years, the survival to any event was 89.4% (95% CI 82 to 93.8), with 96 patients at risk. At 20 years, the survival to any event was 82.5% (95% CI 71.9 to 89.3), with one patient at risk. Five hips (4.4%) had deep infection. Two patients (1.8%) developed dissociated constraining rings with pain but without dislocation, which required re-operation. Two patients (1.8%) had periprosthetic femoral fractures, without dislocation, that were treated by revision stems along with exchange of the well-functioning constrained liners.ConclusionConstrained tripolar liners used at revision hip arthroplasty provided favourable results in the long term for treatment of recurrent dislocation and for patients at high risk of dislocation. Cite this article: Bone Joint J 2019;101-B(6 Supple B):123–126.


2013 ◽  
Vol 23 (4) ◽  
pp. 352-358 ◽  
Author(s):  
Per B. Thomsen ◽  
Niels J.F. Jensen ◽  
Jens Kampmann ◽  
Torben Bæk Hansen

2019 ◽  
Vol 101-B (7) ◽  
pp. 787-792 ◽  
Author(s):  
K. Goto ◽  
Y. Kuroda ◽  
T. Kawai ◽  
K. Kawanabe ◽  
S. Matsuda

Aims In the 1990s, a bioactive bone cement (BABC) containing apatite-wollastonite glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl methacrylate resin was developed at our hospital. In 1996, we used BABC to fix the acetabular component in primary total hip arthroplasty (THA) in 20 patients as part of a clinical trial. The purpose of this study was to investigate the long-term results of primary THA using BABC. Patients and Methods A total of 20 patients (three men and 17 women) with a mean age of 57.4 years (40 to 71), a mean body weight of 52.3 kg (39 to 64), and a mean body mass index (BMI) of 23.0 kg/m2 (19.8 to 28.6) were evaluated clinically and radiologically. Survival analyses were undertaken, and wear analyses were carried out using a computer-aided method. Results The mean follow-up was 17.6 years (1.5 to 21.1). Radiological loosening occurred in four sockets with aseptic loosening at a mean of 7.8 years (1.5 to 20.7). Kaplan–Meier survival analyses using revision of the acetabular component, radiological loosening of the acetabular component, and the worst-case scenario with revision of the acetabular component to include the two patients lost to follow-up as endpoints yielded survival rates of 94.7%, 84.4%, and 85.0% at ten years, and 70.0%, 84.4%, and 62.8% at 20 years, respectively. Wear analysis revealed a mean linear wear rate of 0.068 mm per year. Conclusion The long-term results of primary THAs using BABC were unsatisfactory. Its brittle nature and poor handling properties need to be improved before it becomes an alternative method of fixing the acetabular component in cemented THA. Cite this article: Bone Joint J 2019;101-B:787–792.


2020 ◽  
Vol 26 (2) ◽  
pp. 31-49
Author(s):  
R. M. Tikhilov ◽  
A. A. Dzhavadov ◽  
A. N. Kovalenko ◽  
A. O. Denisov ◽  
A. S. Demin ◽  
...  

The purposes of the retrospective cohort study were: 1) to determine the severity of defects in the acetabulum and the probable causes of their formation in patients who underwent revision hip arthroplasty (RHA), as well as an assessment of factors that exacerbate the severity of the defects; 2) identifying the proportion of severe defects in the overall structure of acetabular revisions and determining the effectiveness of using serial implants in comparison with individual constructions made by 3D printing; 3) the rationale for rational indications for the use of individual constructions.Materials and Methods. The structure and reasons for the formation of bone defects in the acetabulum were evaluated in 726 cases of revisions performed from 2004 to 2018. In addition, the results of revision operations in a group of patients with severe defects (type 3 according to Paprosky and pelvic discontinuity) were evaluated.Results. The most frequent cause of defect formation was iatrogenic (53.2%), and the share of severe defects was 39.5% (287 observations). A factor aggravating the severity of the defect is the lack of its limitation by the support bone. The results of RHA in patients with severe defects were assessed in 186 cases out of 287 (64.8%). In 73 (39.2%) cases, individual constructions were used, the average follow-up was 26 months. (from 12 to 50), and in 113 (60.8%) cases, serial implants were used, the average follow-up period was 62 months. (12 to 186). Individual constructions were more often implanted in patients with 3B acetabular defects (p<0.05) and its uncontained defects (p<0.001). The number of cases of aseptic loosening in the group of patients undergoing endoprosthetics using serial implants was greater than in the group of patients with individual constructions for the entire period (p<0.05) and in the early stages of observation (p<0.05).Conclusion. In case of RHA in patients with severe acetabular defects, individual implants, in comparison with serials, demonstrate better survival with an average follow-up of 26 months and due to design features, they can count on great long-term effectiveness. This study needs to be continued to increase follow-up.


2018 ◽  
Vol 26 (3) ◽  
pp. 230949901881224 ◽  
Author(s):  
Joon Soon Kang ◽  
Yeop Na ◽  
Bong Seong Ko ◽  
Yoon Sang Jeon

Purpose: Revision hip arthroplasty is a very challenging procedure. Use of a modular distal fixation stem is one of the available options for revision arthroplasty in patients with proximal femoral bone deficiency. The purpose of this study was to evaluate mid- to long-term outcomes of cementless modular distal fixation femoral stem implantation in revision hip surgery. Methods: Clinical and radiological findings, complications, and stem survival rate were analyzed for 46 patients (48 hips) who underwent revision hip arthroplasty using a cementless modular distal fixation femoral stem. The mean patient age was 58.8 years (range 31–82 years) and the mean follow-up period was 95 months (72–122 months). The preoperative diagnoses were aseptic loosening (36 hips), infection (4 hips), ceramic fracture (4 hips), and femoral periprosthetic fracture (4 hips). Results: The mean Harris hip score improved from 56.6 preoperatively to 88.2 postoperatively at the last follow-up. All hips showed stable osteointegration and firm fixation. Complications involved four hips (8.3%); there was one case each of periprosthetic fracture, delayed union of osteotomy site, femoral perforation, and infection. One stem re-revision was performed for deep infection of the femoral side. The Kaplan–Meier survival rate was 97.6% at the final follow-up. Conclusion: Revision hip arthroplasty using a cementless modular distal fixation femoral stem showed satisfactory initial firm fixation and mid- to long-term survival rate. Complications can be minimized by careful surgical planning and meticulous procedure.


2014 ◽  
Vol 29 (8) ◽  
pp. 1559-1565 ◽  
Author(s):  
Atesch Ateschrang ◽  
Kuno Weise ◽  
Siegfried Weller ◽  
Ulrich Stöckle ◽  
Peter de Zwart ◽  
...  

2019 ◽  
Vol 27 (2) ◽  
pp. 230949901985803
Author(s):  
Goksel Dikmen ◽  
Vahit Emre Ozden ◽  
Fırat Gulagaci ◽  
I. Remzi Tozun

Purpose: The purpose of this study was to report the long-term results of total hip arthroplasty (THA) for the treatment of ankylosed hip. Methods: Twenty-nine consecutive THAs were performed in 26 patients. The mean age of the patients at the time of the operation was 43.3 years (range, 19–69 years). We used cementless fixation in all hips and the mean duration of follow-up was 10.1 years (range, 4.5–20 years). Radiological evaluation of components, osteolysis, radiolucent lines and loosening were assessed. The Harris Hip Score (HHS), range of motion (ROM), limb-length discrepancy and walking capacity with or without any support were used preoperatively and at final follow-up for clinical evaluation. Survivorship analysis was conducted using the Kaplan–Meier method using second revision for any reason as the endpoint. Results: The mean HHS was 85.6 (range, 55–98) points and mean ROM was 110.5° for flexion. The mean limb-length discrepancy improved from 4.1 cm to 1.1 cm. Positive Trendelenburg sign was recorded in 31% of the patients and 24% of patients needed any support for walking postoperatively. We observed surgical complications related to abductor arm in 25% of the patients. Radiolucency on the acetabular side was seen on one or more zones in 15 patients (16 hips). One aseptic acetabular component loosening was observed. On the femoral side, 11 patients demonstrated non-progressive radiolucent lines and osteolysis around the stem was seen in four hips but there was no aseptic stem loosening. The Kaplan–Meier survival rate considering revision for any reason as the endpoint was 81.5%, for aseptic loosening 91.3%, for a worst-case scenario of 66.4% at 10 years. Conclusion: Cementless fixation showed good to excellent results at 10 years. Preoperative and postoperative abductor status of the patient is critical for patient satisfaction.


Sign in / Sign up

Export Citation Format

Share Document