Size-resolved source apportionment of carbonaceous particulate matter in urban and rural sites in central California

2011 ◽  
Vol 45 (24) ◽  
pp. 3988-3995 ◽  
Author(s):  
Walter A. Ham ◽  
Michael J. Kleeman
2016 ◽  
Vol 9 (1) ◽  
pp. 23-39 ◽  
Author(s):  
K. R. Daellenbach ◽  
C. Bozzetti ◽  
A. Křepelová ◽  
F. Canonaco ◽  
R. Wolf ◽  
...  

Abstract. Field deployments of the Aerodyne Aerosol Mass Spectrometer (AMS) have significantly advanced real-time measurements and source apportionment of non-refractory particulate matter. However, the cost and complex maintenance requirements of the AMS make its deployment at sufficient sites to determine regional characteristics impractical. Furthermore, the negligible transmission efficiency of the AMS inlet for supermicron particles significantly limits the characterization of their chemical nature and contributing sources. In this study, we utilize the AMS to characterize the water-soluble organic fingerprint of ambient particles collected onto conventional quartz filters, which are routinely sampled at many air quality sites. The method was applied to 256 particulate matter (PM) filter samples (PM1, PM2.5, and PM10, i.e., PM with aerodynamic diameters smaller than 1, 2.5, and 10 µm, respectively), collected at 16 urban and rural sites during summer and winter. We show that the results obtained by the present technique compare well with those from co-located online measurements, e.g., AMS or Aerosol Chemical Speciation Monitor (ACSM). The bulk recoveries of organic aerosol (60–91 %) achieved using this technique, together with low detection limits (0.8 µg of organic aerosol on the analyzed filter fraction) allow its application to environmental samples. We will discuss the recovery variability of individual hydrocarbon ions, ions containing oxygen, and other ions. The performance of such data in source apportionment is assessed in comparison to ACSM data. Recoveries of organic components related to different sources as traffic, wood burning, and secondary organic aerosol are presented. This technique, while subjected to the limitations inherent to filter-based measurements (e.g., filter artifacts and limited time resolution) may be used to enhance the AMS capabilities in measuring size-fractionated, spatially resolved long-term data sets.


2015 ◽  
Vol 8 (8) ◽  
pp. 8599-8644 ◽  
Author(s):  
K. R. Daellenbach ◽  
C. Bozzetti ◽  
A. Křepelová ◽  
F. Canonaco ◽  
R. Wolf ◽  
...  

Abstract. Field deployments of the Aerodyne Aerosol Mass Spectrometer (AMS) have significantly advanced real-time measurements and source apportionment of non-refractory particulate matter. However, the cost and complex maintenance requirements of the AMS make impractical its deployment at sufficient sites to determine regional characteristics. Furthermore, the negligible transmission efficiency of the AMS inlet for supermicron particles significantly limits the characterization of their chemical nature and contributing sources. In this study, we utilize the AMS to characterize the water-soluble organic fingerprint of ambient particles collected onto conventional quartz filters, which are routinely sampled at many air quality sites. The method was applied to 256 particulate matter (PM) filter samples (PM1, PM2.5, PM10) collected at 16 urban and rural sites during summer and winter. We show that the results obtained by the present technique compare well with those from co-located online measurements, e.g. AMS or Aerosol Chemical Speciation Monitor (ACSM). The bulk recoveries of organic aerosol (60–91 %) achieved using this technique, together with low detection limits (0.8 μg of organic aerosol on the analyzed filter fraction) allow its application to environmental samples. We will discuss the recovery variability of individual hydrocarbon, oxygen containing and other ions. The performance of such data in source apportionment is assessed in comparison to ACSM data. Recoveries of organic components related to different sources as traffic, wood burning and secondary organic aerosol are presented. This technique, while subjected to the limitations inherent to filter-based measurements (e.g. filter artifacts and limited time resolution) may be used to enhance the AMS capabilities in measuring size-fractionated, spatially-resolved long-term datasets.


Author(s):  
Baoqing Wang ◽  
Deqing Wang ◽  
Qitao Ma ◽  
Shuai Yin ◽  
Shu Yao

2017 ◽  
Author(s):  
Carlo Bozzetti ◽  
Imad El Haddad ◽  
Dalia Salameh ◽  
Kaspar Rudolf Daellenbach ◽  
Paola Fermo ◽  
...  

Abstract. We investigated the seasonal trends of OA sources affecting the air quality of Marseille (France) which is the largest harbor of the Mediterranean Sea. This was achieved by measurements of nebulized filter extracts using an aerosol mass spectrometer (offline-AMS). PM2.5 (particulate matter with an aerodynamic diameter


2016 ◽  
Vol 16 (5) ◽  
pp. 1179-1190 ◽  
Author(s):  
Sunday A. Orogade ◽  
Kayode O. Owoade ◽  
Philip K. Hopke ◽  
Donatus B. Adie ◽  
Abubakar Ismail ◽  
...  

2012 ◽  
Vol 55 ◽  
pp. 525-532 ◽  
Author(s):  
Yungang Wang ◽  
Philip K. Hopke ◽  
Xiaoyan Xia ◽  
Oliver V. Rattigan ◽  
David C. Chalupa ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document