Variation of P-wave indices in paroxysmal atrial fibrillation patients before and after catheter ablation

2021 ◽  
Vol 66 ◽  
pp. 102500 ◽  
Author(s):  
Nuria Ortigosa ◽  
Guillermo Ayala ◽  
Óscar Cano
2019 ◽  
Vol 53 ◽  
pp. e21
Author(s):  
Elena Blinova ◽  
Tamara Sakhnova ◽  
Oleg Sapelnikov ◽  
Dmitriy Cherkashin ◽  
Renat Akchurin

2018 ◽  
Vol 51 (6) ◽  
pp. 1182-1183
Author(s):  
Elena Blinova ◽  
Tamara Sakhnova ◽  
Oleg Sapelnikov ◽  
Dmitriy Cherkashin ◽  
Renat Akchurin

EP Europace ◽  
2019 ◽  
Vol 21 (8) ◽  
pp. 1193-1202
Author(s):  
Giuseppe Ciconte ◽  
Gabriele Vicedomini ◽  
Wenwen Li ◽  
Jan O Mangual ◽  
Luke McSpadden ◽  
...  

Abstract Aims Clinical outcomes after radiofrequency catheter ablation (RFCA) remain suboptimal in the treatment of non-paroxysmal atrial fibrillation (AF). Electrophysiological mapping may improve understanding of the underlying mechanisms. To describe the arrhythmia substrate in patients with persistent (Pers) and long-standing persistent (LSPers) AF, undergoing RFCA, using an integrated mechanism mapping technique. Methods and results Patients underwent high-density electroanatomical mapping before and after catheter ablation. Integrated maps characterized electrogram (EGM) cycle length (CL) in regions with repetitive–regular (RR) activations, stable wavefront propagation, fragmentation, and peak-to-peak bipolar voltage. Among 83 patients (72% male, 60 ± 11 years old), RR activations were identified in 376 regions (mean CL 180 ± 31 ms). PersAF patients (n = 43) showed more RR sites per patient (5.3 ± 2.4 vs. 3.7 ± 2.1, P = 0.002) with faster CL (166 ± 29 vs. 190 ± 29 ms; P < 0.001) and smaller surface area of fragmented EGMs (15 ± 14% vs. 27 ± 17%, P < 0.001) compared with LSPersAF. The post-ablation map in 50 patients remaining in AF, documented reduction of the RR activities per patient (1.5 ± 0.7 vs. 3.7 ± 1.4, P < 0.001) and area of fragmentation (22 ± 17% vs. 8 ± 9%, P < 0.001). Atrial fibrillation termination during ablation occurred at RR sites (0.48 ± 0.24 mV; 170.5 ± 20.2 ms CL) in 31/33 patients (94%). At the latest follow-up, arrhythmia freedom was higher among patients receiving ablation >75% of RR sites (Q4 82.6%, Q3 63.1%, Q2 35.1%, and Q1 0%; P < 0.001). Conclusion The integrated mapping technique allowed characterization of multiple arrhythmic substrates in non-paroxysmal AF patients. This technique might serve as tool for a substrate-targeted ablation approach.


2020 ◽  
Vol 23 (5) ◽  
pp. E703-E711
Author(s):  
Guangli Yin ◽  
Bofei Ma ◽  
Bolun Zhou ◽  
Jinglan Wu ◽  
Ling You ◽  
...  

Background: Catheter ablation for atrial fibrillation (AF) has been gaining popularity; however, the trend of inflammatory response markers in patients treated with different catheter ablation strategies over time and their predictability of AF recurrence remain unknown. Methods: A total of 210 patients with AF were enrolled and grouped according to surgical mode as follows: freeze group, RF group, and freeze3D group. The subjects were tested for related indexes before and after surgery. To determine AF recurrence during follow up, 24-h ambulatory electrocardiography was performed at two, three, six, and 12 months after surgery. Results: The inflammation indexes of the three groups peaked between one and three days after surgery but fell at different time points (P < .05). The recurrence rate of paroxysmal atrial fibrillation (PAF) was positively correlated with the increase in the percentage of white blood cells and neutrophils after surgery (P < .05). Conclusions: The postoperative inflammation indices peaked and fell at different time points after different catheter ablation methods. In addition, the recurrence rate of AF in patients treated with freeze3D is lower.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1923
Author(s):  
Nuria Ortigosa ◽  
Óscar Cano ◽  
Frida Sandberg

Atrial fibrillation is the most common type of cardiac arrhythmia in clinical practice. Currently, catheter ablation for pulmonary-vein isolation is a well-established treatment for maintaining sinus rhythm when antiarrhythmic drugs do not succeed. Unfortunately, arrhythmia recurrence after catheter ablation remains common, with estimated rates of up to 45%. A better understanding of factors leading to atrial-fibrillation recurrence is needed. Hence, the aim of this study is to characterize changes in the atrial propagation pattern following pulmonary-vein isolation, and investigate the relation between such characteristics and atrial-fibrillation recurrence. Fifty patients with paroxysmal atrial fibrillation who had undergone catheter ablation were included in this study. Time-segment and vectorcardiogram-loop-morphology analyses were applied to characterize P waves extracted from 1 min long 12-lead electrocardiogram segments before and after the procedure, respectively. Results showed that P-wave vectorcardiogram loops were significantly less round and more planar, P waves and PR intervals were significantly shorter, and heart rate was significantly higher after the procedure. Differences were larger for patients who did not have arrhythmia recurrences at 2 years of follow-up; for these patients, the pre- and postprocedure P waves could be identified with 84% accuracy.


Sign in / Sign up

Export Citation Format

Share Document