Long-term follow-up of total arterial versus conventional and hybrid myocardial revascularization: A propensity score matched analysis

2019 ◽  
Vol 20 (1) ◽  
pp. 22-28 ◽  
Author(s):  
Lorenzo Di Bacco ◽  
Alberto Repossini ◽  
Maurizio Tespili ◽  
Claudio Muneretto ◽  
Gianluigi Bisleri
1985 ◽  
Vol 6 (5) ◽  
pp. 1121-1125 ◽  
Author(s):  
Arun K. Singh ◽  
Robert Rivera ◽  
George N. Cooper ◽  
Karl E. Karlson

Coatings ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 442 ◽  
Author(s):  
Georg Hauer ◽  
Lukas Leitner ◽  
Marc C. Ackerl ◽  
Sebastian Klim ◽  
Ines Vielgut ◽  
...  

Background: The impact of titanium nitride (TiN) coating on implant components is controversial. TiN coating is proposed as having superior biomechanical properties compared to conventional cobalt-chromium (CoCr) alloy. This study compared long-term clinical data as well as meteoro-sensitivity in patients who underwent total knee arthroplasty (TKA), with either CoCr alloy or TiN coating. Methods: In this retrospective observational study, the clinically approved cemented “low contact stress” (LCS) TKA with conventional CoCr coating, was compared to un-cemented TiN-coated “advanced coated system” (ACS) TKA. Propensity score matching identified comparable patients based on their characteristics in a one-to-one ratio using the nearest-neighbor method. The final cohort comprised 260 knees in each cohort, with a mean follow-up of 10.1 ± 1.0 years for ACS patients and 14.9 ± 3.0 years for the LCS group. Physical examinations, meteoro-sensitivity, and knee scoring were assessed. Results: The clinical and functional Knee Society Score (KSS) (82.6 vs. 70.8; p < 0.001 and 61.9 vs. 71.1; p = 0.011), the postoperative Visual Analogue Scale (VAS) (2.9 vs. 1.4; p = 0.002), and the postoperative Tegner Score (2.6 vs. 2.2; p = 0.001) showed significant intergroup differences. The postoperative Western Ontario & McMaster Universities Osteoarthritis Index (WOMAC) was similar (79.9 vs. 81.3; p = 0.453) between groups. Meteoro-sensitivity of the artificial joint was significantly more prevalent in the ACS patient cohort (56% vs. 23%; p < 0.001). Conclusion: This study suggests that TiN coating does not provide improved clinical outcomes in this patient cohort after a long-term follow-up. Interestingly, sensitivity to weather changes were more correlated with un-cemented ACS implants.


2020 ◽  
Vol 28 (6) ◽  
pp. 316-321
Author(s):  
Vladlen Bazylev ◽  
Evgeny Rosseikin ◽  
Dmitriy Tungusov ◽  
Artur Mikulyak

Background The method of coronary-coronary bypass grafting was described in 1987 but has not been widely used, and there are only a few studies that report good short-term and mid-term results as well as some individual cases of long-term follow-up. In our medical institution, we carried out an analysis of the long-term results of coronary-coronary bypass grafting, which are presented in this study. Methods This was a retrospective single-center study on 95 patients who underwent coronary-coronary bypass grafting as a supplement to the standard coronary bypass grafting procedure. All patients underwent angiographic assessment of the coronary bypass grafts during the long-term follow-up period. The observation period was up to 123 months. Angiographic assessment of 109 coronary-coronary grafts was carried out. Results Twelve (7.6%) arterial and 11 (19.3%) venous conduits were found to be occluded, and 8 (10.3%) arterial and 10 (31.3%) venous coronary-coronary grafts were occluded during the observation period. Conclusion Arterial coronary-coronary artery bypass grafting represents an alternative technique that allows complete myocardial revascularization.


2019 ◽  
Vol 8 (12) ◽  
pp. 2126 ◽  
Author(s):  
Marijana Tadic ◽  
Cesare Cuspidi ◽  
Vera Celic ◽  
Biljana Pencic ◽  
Giuseppe Mancia ◽  
...  

We aimed to investigate the predictive value of 24 h blood pressure (BP) patterns on adverse cardiovascular (CV) outcome in the initially untreated hypertensive patients during long-term follow-up. This study included 533 initially untreated hypertensive patients who were involved in this study in the period between 2007 and 2012. All participants underwent laboratory analysis, 24 h BP monitoring, and echocardiographic examination at baseline. The patients were followed for a median period of nine years. The adverse outcome was defined as the hospitalization due to CV events (atrial fibrillation, myocardial infarction, myocardial revascularization, heart failure, stroke, or CV death). During the nine-year follow-up period, adverse CV events occurred in 85 hypertensive patients. Nighttime SBP, non-dipping BP pattern, LV hypertrophy (LVH), left atrial enlargement (LAE), and LV diastolic dysfunction (LV DD) were risk factors for occurrence of CV events. However, nighttime SBP, non-dipping BP pattern, LVH, and LV DD were the only independent predictors of CV events. When all four BP pattern were included in the model, non-dipping and reverse dipping BP patterns were associated with CV events, but only reverse-dipping BP pattern was independent predictor of CV events. The current study showed that reverse-dipping BP pattern was predictor of adverse CV events independently of nighttime SBP and LV remodeling during long-term follow-up. The assessment of BP patterns has very important role in the long-time prediction in hypertensive population.


2017 ◽  
Vol 103 (2) ◽  
pp. 517-525 ◽  
Author(s):  
Gianluigi Bisleri ◽  
Lorenzo Di Bacco ◽  
Dario Turturiello ◽  
Angelica Mazzoletti ◽  
Laura Giroletti ◽  
...  

HPB ◽  
2021 ◽  
Vol 23 ◽  
pp. S818-S819
Author(s):  
T. Giuliani ◽  
M. De Pastena ◽  
S. Paiella ◽  
G. Marchegiani ◽  
L. Landoni ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document