Adverse Events and Modes of Failure Related to Impella RP: Insights from the Manufacturer and User Facility Device Experience (MAUDE) Database

2019 ◽  
Vol 20 (6) ◽  
pp. 503-506 ◽  
Author(s):  
Nauman Khalid ◽  
Toby Rogers ◽  
Evan Shlofmitz ◽  
Yuefeng Chen ◽  
Anees Musallam ◽  
...  
2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0009
Author(s):  
Craig C. Akoh ◽  
Rishin J. Kadakia ◽  
Jie Chen ◽  
Young-uk Park ◽  
Hyong Nyun Kim ◽  
...  

Category: Midfoot/Forefoot; Other Introduction/Purpose: The prevalence of osteoarthritis of the hallux metatarsophalangeal joint (MTPJ) is estimated to affect 1 in 40 people over the age of 50. Surgical treatment options for MTPJ arthritis include joint preservation, joint resurfacing, and salvage arthrodesis. Arthroplasty of the great toe MTPJ has evolved over the past several decades. The aims of this study were to examine the MAUDE database to determine reported adverse events for hallux MTPJ arthroplasty. Methods: The US Food and Drug Administration’s (FDA) Manufacturer and User Facility Device Experience (MAUDE) database was reviewed from 2010-2018 to determine reported adverse events for approved implants. We recorded and categorized the type of adverse event and excluded duplicate reports and those extracted from already published literature. Results: Among 64 unique hallux MTPJ implant adverse events, the most common modes of failure were component loosening (34%), component fracture (9.4%), inflammation (9.4%), infection (14.1%), and allergic reaction (7.8%). In regards to implant type, synthetic implants (Cartiva) had the highest percentage of adverse events (23.4%), followed by Arthrosurface ToeMotion (20.3%), Ascension MGT (12.5%), Arthrosurface HemiCAP (10.9%), Futura primus (9.4%), and Osteomed Reflexion (6.3%). The number of adverse events reported increased substantially after 2016. Conclusion: Our study of the MAUDE database demonstrated that component loosening and infection are the most common modes of adverse events for hallux MTPJ implants. Cartiva accounted for one-fourth of the implant-related adverse events during our study period, followed by ToeMotion and Ascension MGT implants. Given that the adverse events for hallux MTPJ implants are underreported, improved reporting mechanisms should be utilized to improve our understanding on long-term effects of various hallux MTPJ implants. [Table: see text]


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Yagya Pandey ◽  
Nauman Khalid ◽  
Mirza Khalid ◽  
Hassan Kamran ◽  
Hussain Raza ◽  
...  

Introduction: Fractional Flow Reserve (FFR) measurement is commonly used in the cardiac catheterization laboratory to assess functional significance of coronary arterial plaques. Robust real-world data on complications and modes of failure of FFR guidewires are limited. We analyzed the post-marketing surveillance data from the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database to report these endpoints for commonly utilized FFR guidewire. Methods: MAUDE database was queried from January 1, 2010, to April 1, 2020, for 3 commonly used FFR guidewires (PressureWire TM X (Abbott), Comet TM (Boston Scientific) and Verrata TM (Philips)) by searching for following events: “injury”, “malfunction”, “death”, and “other” yielding 544 reports. After excluding incomplete reports and older devices not in current use, 486 reports were analyzed. Results: Figure 1 shows reported modes of failure and patient adverse events. Guidewire tip fracture was the most reported mode of failure in 174 (35.8%) cases. Guidewire kinking (n= 152 (31.3%)), communication failure (n= 141 (29.0%)), and shaft fracture (n= 67 (13.8%)) were also reported. 133 (27.4%) of total device failures resulted in patient adverse events. Most common patient adverse event was retained guidewire tip in 71 (53.4%) cases followed by freshly deployed stent dislodgment (n= 26 (19.6%)) and coronary artery dissection (n=23 (17.3%)) respectively. 6 patient deaths were reported. Conclusions: FFR guidewire failures can occur due to a variety of mechanisms and lead to patient adverse events. MAUDE database serves as an important platform for improved collaboration between clinicians, device manufacturers, and regulatory bodies to improve device performance and optimize patient outcomes. Our analysis provides insights into the mechanism of FFR guidewire failure and associated adverse events but cannot verify causality or provide a comparison among different guidewires.


2019 ◽  
Vol 4 (4) ◽  
pp. 2473011419S0028
Author(s):  
Karim Mahmoud ◽  
Sreenivasulu Metikala ◽  
Kathryn O’Connor ◽  
Daniel Farber

Category: Ankle Arthritis Introduction/Purpose: Total ankle replacement has become a popular treatment option for end stage ankle arthritis. Most of the reports of adverse events following total ankle replacement have been from high volume institutions and are subject to either observational or selection bias as well as potential under-reporting as they do not include the experience of community and lower volume centers and surgeons. The FDA’s Medical and User Facility Device Experience (MAUDE) Database provides a more complete scope of adverse events due to the mandatory reporting requirements by the FDA of implant manufactures. We reviewed the database to identify the common modes of failure and complications of total ankle implants Methods: We retrospectively reviewed reports of the MAUDE database from November 2011 to September 2018 regarding all total ankle implants. Each device in the MAUDE database is classified with a 3-letter code, we identified the 2 codes assigned to total ankle arthroplasty devices, and manually searched the FDA’s published Device Classification list for adverse events. All events were reviewed and classified. Data related to patient age or sex, surgeon, medical center location are not available in the database Results: We identified 1000 adverse reports in the period between November 2011 and September 2018. After exclusion of duplicate reports for single events or reports irrelevant to total ankle arthroplasty, a total of 697 adverse event reports were noted. The most common mode of failure was aseptic loosening (21%), followed by infection (16%), alignment and mechanical issues (instability, malalignment, malposition, stiffness, impingement) (15%), implantation issues (pin, screw or drill breakage, alignment guide problems) (9%), polyethylene related problems (wear, displaced or fractured implants) (7%), bony and soft tissue overgrowth (6%), and peri-prosthetic fractures (5%). Conclusion: Our analysis reveals that the most reported mode of failure was aseptic loosening followed by infection. However, it is notable that there are a significant number of issues with implant alignment and mechanics, complications during implantation and polyethylene component failure that are under-reported in the literature. Knowledge of these adverse events may help surgeons avoid similar complications as well as lead to improvement in component implantation and design


Circulation ◽  
2018 ◽  
Vol 138 (Suppl_1) ◽  
Author(s):  
Naveen Kumar Sankaran ◽  
Sai Rakesh Rachakonda ◽  
Abraham Kocheril ◽  
Suraj Kapa ◽  
Thenkurussi Kesavadas

Introduction: Endovascular procedures are traditionally performed for a variety of indications. However, guidewire/catheter manipulation and hazardous radiation exposure are limitations to manual interventions. Thus, significant work has been done to develop robotic approaches to therapies. These devices have FDA clearance for performing procedures like cardiac arrhythmias, angioplasty, aneurysm repair and stenting etc. With the increasing usage of robotic assistance in endovascular procedures, it is essential to understand the adverse events that may occur. This study aims to provide an understanding of adverse events with currently available robotic systems. Methods: The analysis of adverse events is performed with the FDA MAUDE (Manufacturer and User Facility Device Experience) database. MAUDE database is a collection of reports on medical devices reported by manufacturers, distributors, users, volunteers. In case of occurrence of adverse events, FDA regulations requires that event to be reported for further investigation. Based on the impact of events on the patient’s outcome, the reported events were grouped into 3 categories death (patient death), injury (patient injury) or device malfunction. Results: A total of 71 different events were reported collectively for all the four robotic devices (Hansen Medical- 37, Corindus Inc.-27, Stereotaxis Inc.-5 & Catheter Robotics Inc.-2). The major adverse events included death and common injuries such as perforation, pseudo-aneurysm / blockage/ tamponade/ clot, blood pressure dropped or an effusion, or hemodynamic instability. The table summarizes the events by brand of system. Conclusions: While robotic approaches to intervention reflect a potentially useful means to improve outcomes of endovascular procedures by optimizing catheter manipulation with finer robotic motions or limiting radiation exposure, there are potentially significant risks. Whether these reflect higher or lower risk than traditional manual approaches requires randomized studies. Use of robotic technologies may present additional risks in light of potential malfunctions that occur from system errors that a human system may not be prone to. Future studies will be needed to better understand incremental benefit.


Author(s):  
Linda Burkett ◽  
Pamela Moalli ◽  
Mary Ackenbom

Abstract Background Description of energy-based genitourinary non-surgical devices (energy-based devices) safety data is outlined given their rapid adoption. Objectives To describe adverse events (AEs) for energy-based devices in the Manufacturer and User Facility Device Experience (MAUDE) database, and to compare to similar devices and other subspecialty applications. We hypothesized that products with genitourinary applications had similar AEs to dermatologic or general surgery applications. Methods Reed Tech™ Navigator compiled AE reports for all registered energy-based devices. Individual AE reports associated with 1) non-ablative, 2) fractionated, 3) unfractionated 4) radiofrequency, and 5) hybrid laser technologies were categorized. AE characteristics were compared among genitourinary applications (n=39) and other subspecialty applications within the same devices (n=79). Results Eighteen manufacturers were identified, which collectively manufacture 43 products with genitourinary applications. Thirty-nine genitourinary AEs were reported and isolated to 6 manufacturers with 11 products, of which 82% (n=32) were injuries, 15% (n=6) were device malfunction, and 3% (n=1) related to improper maintenance. Local treatment reactions were the most commonly reported injury (62%, n=21). AEs varied by device type with CO2 lasers having more burns and radiofrequency devices having higher rates of sensation loss. When comparing similar technology types, genitourinary energy-based devices had the least AE reports per device in MAUDE database. Conclusions AEs were reported on a quarter of the products currently available, and most were local treatment reactions. The reporting of AEs is equal to that of other subspecialties suggesting similar risk profiles. Improved reporting is needed to fully evaluate the safety of individual energy-based devices.


Stroke ◽  
2013 ◽  
Vol 44 (suppl_1) ◽  
Author(s):  
Wondwossen G Tekle ◽  
Malik M Adil ◽  
Derya Uluduz ◽  
Basit Rahim ◽  
Tauhid Awan ◽  
...  

Background: There is paucity of knowledge regarding the spectrum of neurothrombectomy(NT) device-related complications. Objective: To report the characteristics and proportions of reported adverse-events(AE) related to NT devices used in endovascular treatment of acute ischemic stroke (AIS). Methods: We identified NT device-related AE reported by voluntary sources, user facility reports, and distributor and manufacturer reports to the Manufacturer and User Facility Device Experience Database(MAUDE) from the year 2004 through 2012 to identify patients. Frequency of specific reported AE and associated factors were extracted from the “event description” on the three NT devices currently in use for AIS treatment -Merci Retriever, Penumbra System, and Solitaire-FR stentriever. Results: A total of 706 reported NT device-related AEs were identified with a continual increase in reporting rate since 2004. Of the 706, device malfunction (kink, twist, difficult advancing, fracture, or retention) was the most common reported complication(56%), followed by hemorrhages(23%), dissection(6.8%), vasospasm(6.2%), and distal embolism(2.7%). Intra-arterial(IA) thrombolytic was used in 70%(111/159), intravenous(IV) thrombolytic in 16%, and both IA and IV in 13% of the reported cases. Middle cerebral artery(MCA) was involved in 56%(220/392), internal carotid artery(ICA) in 16 %, and both MCA and ICA in about 21% of cases where the occluded vessel was reported. Multiple devices were used in majority(71%) of reported cases(n=564). The first “pass”(recanalization-attempt) was associated with 34% of reported adverse event per-device(n= 119), 2-passes(29%), and 3-passes(28%). Recanalization was complete in 52 %(266/513) reported cases, and partial in 14%(71/513). Patients’ condition was unchanged in 63%(220/349), worsened in 29%(101/349), and improved in 8%(28/349) of reported cases. Twenty three percent(77/342) mortality was reported among those patients whose final outcome was known and reported. Conclusions: Reports of NT device-related AE have significantly increased over the last 8 years. Proportionally higher-rates of reported device malfunction do not necessarily represent adverse patient outcomes.


Sign in / Sign up

Export Citation Format

Share Document