Clinical performance of a new point-of-care cardiac troponin I assay compared to three laboratory troponin assays

2011 ◽  
Vol 412 (3-4) ◽  
pp. 370-375 ◽  
Author(s):  
Søren Hjortshøj ◽  
Per Venge ◽  
Jan Ravkilde
2016 ◽  
Vol 68 (4) ◽  
pp. S41
Author(s):  
P. Hausfater ◽  
S. Blaschke ◽  
E. Giannitsis ◽  
M. Khellaf ◽  
J. Mair ◽  
...  

2018 ◽  
Vol 56 (8) ◽  
pp. 1336-1344 ◽  
Author(s):  
Michael Christ ◽  
Felicitas Geier ◽  
Sabine Blaschke ◽  
Evangelos Giannitsis ◽  
Mehdi Khellaf ◽  
...  

Abstract Background: We evaluated the clinical performance of the Minicare cardiac troponin-I (cTnI), a new point-of-care (POC) cTnI test for the diagnosis of acute myocardial infarction (AMI) in a prospective, multicentre study (ISRCTN77371338). Methods: Of 474 patients (≥18 years) admitted to an emergency department (ED) or chest pain unit (CPU) with symptoms suggestive of acute coronary syndrome (ACS; ≤12 h from symptom onset), 465 were eligible. Minicare cTnI was tested immediately, 3 h and 6 h after presentation. AMI diagnoses were adjudicated independently based on current guidelines. Results: The diagnostic performance of the Minicare cTnI test at 3 h was similar for whole blood and in plasma: sensitivity 0.92 vs. 0.90; specificity 0.91 vs. 0.90; positive predictive value (PPV) 0.68 vs. 0.66; negative predictive value (NPV) 0.98 vs. 0.98; positive likelihood ratio (LR+) 10.18 vs. 9.41; negative likelihood ratio (LR–) 0.09 vs. 0.11. The optimal diagnostic performance was obtained at 3 h using cut-offs cTnI >43 ng/L plus cTnI change from admission ≥18.5 ng/L: sensitivity 0.90, specificity 0.96, PPV 0.81, NPV 0.98, and LR+ 21.54. The area under the receiver operating characteristics (ROC) curve for cTnI whole blood baseline value and absolute change after 3 h curve was 0.93. Conclusions: These data support the clinical usefulness of Minicare cTnI within a 0 h/3 h-blood sampling protocol supported by current guidelines for the evaluation of suspected ACS.


2017 ◽  
Vol 469 ◽  
pp. 119-125 ◽  
Author(s):  
Per Venge ◽  
Lian van Lippen ◽  
Sabine Blaschke ◽  
Michael Christ ◽  
Felicitas Geier ◽  
...  

Author(s):  
Peter A. Kavsak ◽  
Tara Edge ◽  
Chantele Roy ◽  
Paul Malinowski ◽  
Karen Bamford ◽  
...  

AbstractObjectivesTo analytically evaluate Ortho Clinical Diagnostics VITROS high-sensitivity cardiac troponin I (hs-cTnI) assay in specific matrices with comparison to other hs-cTn assays.MethodsThe limit of detection (LoD), imprecision, interference and stability testing for both serum and lithium heparin (Li-Hep) plasma for the VITROS hs-cTnI assay was determined. We performed Passing-Bablok regression analyses between sample types for the VITROS hs-cTnI assay and compared them to the Abbott ARCHITECT, Beckman Access and the Siemens ADVIA Centaur hs-cTnI assays. We also performed Receiver-operating characteristic curve analyses with the area under the curve (AUC) determined in an emergency department (ED)-study population (n=131) for myocardial infarction (MI).ResultsThe VITROS hs-cTnI LoD was 0.73 ng/L (serum) and 1.4 ng/L (Li-Hep). Stability up to five freeze-thaws was observed for the Ortho hs-cTnI assay, with the analyte stability at room temperature in serum superior to Li-Hep with gross hemolysis also affecting Li-Hep plasma hs-cTnI results. Comparison of Li-Hep to serum concentrations (n=202), yielded proportionally lower concentrations in plasma with the VITROS hs-cTnI assay (slope=0.85; 95% confidence interval [CI]:0.83–0.88). In serum, the VITROS hs-cTnI concentrations were proportionally lower compared to other hs-cTnI assays, with similar slopes observed between assays in samples frozen <−70 °C for 17 years (ED-study) or in 2020. In the ED-study, the VITROS hs-cTnI assay had an AUC of 0.974 (95%CI:0.929–0.994) for MI, similar to the AUCs of other hs-cTn assays.ConclusionsLack of standardization of hs-cTnI assays across manufacturers is evident. The VITROS hs-cTnI assay yields lower concentrations compared to other hs-cTnI assays. Important differences exist between Li-Hep plasma and serum, with evidence of stability and excellent clinical performance comparable to other hs-cTn assays.


2019 ◽  
Vol 65 (11) ◽  
pp. 1426-1436 ◽  
Author(s):  
Jasper Boeddinghaus ◽  
Raphael Twerenbold ◽  
Thomas Nestelberger ◽  
Luca Koechlin ◽  
Desiree Wussler ◽  
...  

Abstract BACKGROUND We aimed to validate the clinical performance of the high-sensitivity cardiac troponin I [VITROS® Immunodiagnostic Products hs Troponin I (hs-cTnI-VITROS)] assay. METHODS We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists considering all clinical information, including cardiac imaging: first, using serial hs-cTnT-Elecsys (primary analysis) and, second, using hs-cTnI-Architect (secondary analysis) measurements in addition to the clinically used (hs)-cTn. hs-cTnI-VITROS was measured at presentation and at 1 h in a blinded fashion. The primary objective was direct comparison of diagnostic accuracy as quantified by the area under the ROC curve (AUC) of hs-cTnI-VITROS vs hs-cTnT-Elecsys and hs-cTnI-Architect, and in a subgroup also hs-cTnI-Centaur and hs-cTnI-Access. Secondary objectives included the derivation and validation of an hs-cTnI-VITROS-0/1-h algorithm. RESULTS AMI was the adjudicated final diagnosis in 158 of 1231 (13%) patients. At presentation, the AUC for hs-cTnI-VITROS was 0.95 (95% CI, 0.93–0.96); for hs-cTnT-Elecsys, 0.94 (95% CI, 0.92–0.95); and for hs-cTnI-Architect, 0.92 (95% CI, 0.90–0.94). AUCs for hs-cTnI-Centaur and hs-cTnI-Access were 0.95 (95% CI, 0.94–0.97). Applying the derived hs-cTnI-VITROS-0/1-h algorithm (derivation cohort n = 519) to the validation cohort (n = 520), 53% of patients were ruled out [sensitivity, 100% (95% CI, 94.1–100)] and 14% of patients were ruled in [specificity, 95.6% (95% CI, 93.4–97.2)]. Patients ruled out by the 0/1-h algorithm had a survival rate of 99.8% at 30 days. Findings were confirmed in the secondary analyses using the adjudication including serial measurements of hs-cTnI-Architect. CONCLUSIONS The hs-cTnI-VITROS assay has at least comparable diagnostic accuracy with the currently best validated hs-cTnT and hs-cTnI assays. ClinicalTrials.gov Identifier NCT00470587.


2017 ◽  
Vol 28 (9) ◽  
pp. 1878-1880 ◽  
Author(s):  
Luyang Miao ◽  
Lianhua Zhang ◽  
Lei Jiao ◽  
Xiaofeng Tan ◽  
Qin Wei ◽  
...  

2020 ◽  
Vol 75 (10) ◽  
pp. 1111-1124 ◽  
Author(s):  
Jasper Boeddinghaus ◽  
Thomas Nestelberger ◽  
Luca Koechlin ◽  
Desiree Wussler ◽  
Pedro Lopez-Ayala ◽  
...  

2017 ◽  
Vol 50 (13-14) ◽  
pp. 763-767 ◽  
Author(s):  
Monica Maria Mion ◽  
Giada Bragato ◽  
Alessandra Casarotti ◽  
Chiara Cosma ◽  
Stefania Vigolo ◽  
...  