Effect of Solid Loading and Particle Size on the Phase Holdup Distribution and Bubble Behaviour in a Pilot-Scale Slurry Bubble Column

2021 ◽  
pp. 116732
Author(s):  
Mojtaba Mokhtari ◽  
Jamal Chaouki
2019 ◽  
Vol 79 (4) ◽  
pp. 771-778 ◽  
Author(s):  
Junho Lee ◽  
Myungjin Lee

Abstract This study has been carried out to evaluate the applicability of the pilot scale hybrid type of stormwater runoff treatment system for treatment of combined sewer overflow. Also, to determine the optimum operation parameter such as coagulation dosage concentration, effectiveness of coagulant usage, surface loading rate and backwashing conditions. The pilot scale stormwater filtration system (SFS) was installed at the municipal wastewater plant serving the city of Cheongju (CWTP), Korea. CWTP has a capacity of 280,000 m3/day. The SFS consists of a hydrocyclone coagulation/flocculation with polyaluminium chloride silicate (PACS) and an upflow filter to treat combined sewer overflows. There are two modes (without PACS use and with PACS use) of operation for the SFS. In case of no coagulant use, the range of suspended solids (SS) and turbidity removal efficiency were 72.0–86.6% (mean 80.0%) and 30.9–71.1% (mean 49.3%), respectively. And, the recovery rate of filter was 79.2–83.6% (mean 81.2%); the rate of remaining solid loading in filter media was 16.4–20.8% (mean 18.8%) after backwashing. The influent turbidity, SS concentrations were 59.0–90.7 NTU (mean 72.0 NTU), 194.0–320.0mg/L (mean 246.7mg/L), respectively. The range of PACS dosage concentration was 6.0–7.1mg/L (mean 6.7mg/L). The range of SS and turbidity removal efficiency was 84.9–98.2 (mean 91.4%) and 70.7–96.3 (mean 84.0%), respectively. It was found that removal efficiency was enhanced with PACS dosage. The recovery rate of filter was 92.0–92.5% (mean 92.3%) the rate of remaining solid loading in filter media was 6.1–8.2% (mean 7.2%) after backwashing. In the case of coagulant use, the particle size of the effluent is bigger than influent particle size. The results showed that SFS with PACS use more effective than without PACS use in SS and turbidity removal efficiency and recovery rate of filter.


Author(s):  
Omar M Basha ◽  
Badie I Morsi

AbstractOur rigorously validated Computational Fluid Dynamics (CFD) model (Basha Omar, M., L. Weng, Z. Men, and I. Morsi Badie. 2016. “CFD Modeling with Experimental Validation of the Internal Hydrodynamics in a Pilot-Scale Slurry Bubble Column Reactor.”International Journal of Chemical Reactor Engineering14(2):599–619), was used to predict the effects of spargers design and internals configuration on the local hydrodynamics and flow structure in a pilot-scale (0.3-m ID) and a large-scale (10-m ID) Slurry Bubble Column Reactors (SBCRs), operating under Fisher-Tropsch (F-T) process conditions. In the pilot-scale SBCR without internals, the 6-arms spider created small/fast liquid recirculations in the vicinity of the sparger and slow/large liquid recirculations at about 1.2 times reactor diameter, whereas, the 3-concentric-rings and perforated plate spargers created slow/large recirculations throughout the reactor. In the pilot-scale SBCR with internals, spargers with downward-pointing orifices created larger Sauter mean bubble diameters (ds), leading to more effective solids suspension when compared with those with upward-pointing orifices. Also, 3-concentric-rings spargers resulted in larger Sauter mean bubble diameter values when compared with those of 6-arms spiders. In the large-scale SBCR provided with a large 3-concentric-rings sparger, the effects of vertical parallel and bundled internals on the local hydrodynamics and flow structures were predicted. Bundled internals led to slower and smaller liquid recirculations, smoother radial gas holdup profiles, larger average gas bubbles size, and smaller local gas holdups, when compared those predicted when using parallel internals.


2016 ◽  
Vol 14 (2) ◽  
pp. 599-619 ◽  
Author(s):  
Omar M. Basha ◽  
Li Weng ◽  
Zhuowu Men ◽  
Badie I. Morsi

Abstract A multiphase-Eulerian, three-dimensional (3-D), computational fluid dynamics (CFD) model was built to investigate the local hydrodynamics of a pilot-scale (0.29 m ID, 3 m height) Slurry Bubble Column Reactor (SBCR). The model was first validated against the gas holdup radial profiles in an air-water-glass beads system obtained in a 0.254 m ID and 2.5 m height column under ambient conditions at various superficial gas velocities by Yu and Kim (Bubble characteristics in the radial direction of three-phase fluidized beds. AIChE Journal 34, 2069–2072, 1988). The model was next validated against the gas holdup radial profile data for N2-Drakeol-glass beads system obtained in a 0.44 m ID and 2.44 m height reactor, including internals, operating under ambient conditions at various superficial gas velocities by Chen et al. (Fluid dynamic parameters in bubble columns with internals. Chemical Engineering Science 54, 2187–2197, 1999). The model was also validated against experimental data obtained in our lab for N2-Fischer Tropsch (F-T) reactor wax-Fe catalyst system obtained in a pilot-scale, Slurry Bubble column Reactor, SBCR (0.29 m ID, 3 m height) under pressures and temperatures up to 25.9 bar and 490 K, respectively. These three validations led to the selection of the turbulence and interphase drag coefficient models, and the optimization of the solution method, mesh size and structure and the step size. Moreover, the inclusion of RNG k-ε turbulence model coupled with the Wen-Yu (Mechanics of Fluidization. Chemical Engineering Progress Symposium Series 62, 100–111, 1966) / Schiller-Naumann (A drag coefficient correlation. Zeitung Ver. Deutsch. Ing 77, 318–320, 1935) drag correlations, and the mass transfer coefficients were found to provide the most accurate predictions of the experimental data. The CFD model was then used to investigate local gas holdup, liquid recirculation, local turbulence intensities, bubble diameters, and solids distribution throughout our pilot-scale SBCR, operating under typical F-T process conditions. The model predictions showed strong liquid recirculation and backmixing near the walls of the reactor, and the solid-phase velocity vectors closely followed those of the liquid-phase. A relatively high liquid turbulence intensities were observed in the vicinity of the sparger upon startup, however, after reaching a steady state, the liquid turbulence intensities became more evenly distributed throughout the reactor. The liquid turbulence intensities were slightly higher near the center of the reactor, and closely resembled the velocity vectors. Also, the Sauter mean bubble diameters increased, whereas the solids distribution decreased with reactor height above the gas distributor.


2016 ◽  
Vol 14 (2) ◽  
pp. 653-664 ◽  
Author(s):  
Saba A. Gheni ◽  
Yasser I. Abdulaziz ◽  
Muthanna H. Al-Dahhan

Abstract In this investigation, time average local gas holdup and bubble dynamic data were achieved for three L/D ratios of slurry bubble column. The examined ratios were 3, 4 and 5 in 18″ diameter slurry bubble column. Air-water-glass bead system was used with superficial gas velocity up to 0.24 m/s. The gas holdup was measured using four tips optical fiber probe technique. The results showed that the gas holdup increases almost linearly with the superficial gas velocity in 0.08 m/s and levels off with a further increase of velocity. A comparison of the present data with those reported for other slurry bubble column having diameters greater than 18″ and L/D higher than 5 was made. The results indicated a little effect of diameter on the gas holdup. A local, section-averaged gas holdup increases with increasing superficial gas velocity, while the effect of solid loading are less significant than that of the superficial gas velocity. Chaos analysis was used to analyze the slurry system.


Author(s):  
Huahai Zhang ◽  
Zhongshan Guo ◽  
Yuelin Wang ◽  
Xiankun Shen ◽  
Tiefeng Wang

The effects of particle concentration and size on hydrodynamics and mass transport in a slurry bubble column were experimentally studied. With increasing particle concentration, the averaged gas holdup, gas holdup of small bubbles and gas-liquid volumetric mass transfer coefficient decreased, while the gas holdup of large bubbles increased slightly. With increasing particle size, the averaged gas holdup and kla remained unchanged when the particle size increased from 55 to 92 m, but decreased significantly when the particle size was further increased to 206 m. A liquid turbulence attenuation model which could quantitatively describe the effects of particle concentration and size was first proposed. Semi-empirical correlations were obtained based on extensive experimental data in a wide range of operating conditions and corrected liquid properties. The gas holdup and mass transfer coefficient calculated by the correlations agreed with the experimental data from both two-phase and three-phase bubble columns


Sign in / Sign up

Export Citation Format

Share Document