Monodisperse pillar[5]arene-based polymeric sub-microsphere for on-line extraction coupling with high-performance liquid chromatography to determine antioxidants in the migration of food contact materials

2020 ◽  
Vol 1625 ◽  
pp. 461276
Author(s):  
Ruiyu Liang ◽  
Yuling Hu ◽  
Gongke Li
2021 ◽  
Vol 233 ◽  
pp. 02045
Author(s):  
Yue Qiu ◽  
Qing Zhang ◽  
Genrong Li ◽  
Mei Long ◽  
Dong Xiang

A high performance liquid chromatography (HPLC) method was used to determine 12 acrylate compounds in plastic food contact materials. The plastic food contact material samples were extracted by ultrasonic with methanol. The mixed solution of water and acetonitrile was used as mobile phase for gradient elution. The samples were separated by ZORBAX SB-AQ column (250 mm×4.6 mm, 5 μm), and analyzed by diode array detector (DAD). The results showed that under the optimal chromatographic conditions, the 12 acrylate compounds had good linear relationships in the range of 0.01-10.0 mg/L, the correlation coefficient of the standard curves were higher than 0.999, and the detection limits (LODs) were 0.03-0.08 mg/kg. The recovery rate was between 85.4% and 110.7%, and the relative standard deviation was from 1.6% to 5.2%. The method was simple and accurate, and can be used for the analysis and detection of 12 acrylate compounds in plastic food contact materials.


Molecules ◽  
2019 ◽  
Vol 24 (21) ◽  
pp. 3894 ◽  
Author(s):  
Huaining Zhong ◽  
Zicheng Li ◽  
Sheng Chen ◽  
Ying Zeng ◽  
Jianguo Zheng ◽  
...  

In this study, a target analytical approach using high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) was developed to simultaneously determine six isothiazolinones containing 2-Methylisothiazol-3(2H)-one (MI), 5-Chloro-2-methyl-4-isothiazolin-3-one (CMI), 1,2-benzisothiazolin-3-one (BIT), 2-Octyl-3(2H)-isothiazolinone (OIT), Dichlorooctylisothiazolinone (DCOIT), and 2-methyl-1,2-benzisothiazolin-3-one (MBIT) in water-based adhesive used for food contact materials. The main factors affecting extraction efficiency such as extraction method, extraction time, extraction solvent, and solid–liquid ratio have been evaluated by using real adhesive samples. Multiple-reaction monitoring (MRM) was used for the qualitative and quantitative analyses of targeted isothiazolinones. This method was demonstrated as an effective and reliable technique for detecting multiple isothiazolinones with satisfactory recoveries (81.5~107.3%), and the limits of detection (LOD) and quantification (LOQ) were obtained at a low level. This method was validated and applied to the determination of six isothiazolinones in commercial water-based adhesives. The present results revealed that these adhesives contained a combination of isothiazolinones (BIT, MI, CMI, and MBIT) with the concentration ranging from 2.27 to 123.5 mg/kg. To our knowledge, it is the first time it has been reported that MBIT was detected in water-based adhesives used for food contact materials, which requires a further investigation for its migration to food and the risk to human health.


Sign in / Sign up

Export Citation Format

Share Document