Simultaneous quantification of free triiodothyronine and free thyroxine by isotope dilution tandem mass spectrometry

2007 ◽  
Vol 40 (18) ◽  
pp. 1386-1391 ◽  
Author(s):  
Jianghong Gu ◽  
Offie P. Soldin ◽  
Steven J. Soldin
2005 ◽  
Vol 358 (1-2) ◽  
pp. 113-118 ◽  
Author(s):  
Steven J. Soldin ◽  
Nadia Soukhova ◽  
Natasa Janicic ◽  
Jacqueline Jonklaas ◽  
Offie P. Soldin

2009 ◽  
Vol 55 (7) ◽  
pp. 1380-1388 ◽  
Author(s):  
Jacqueline Jonklaas ◽  
Natasa Kahric-Janicic ◽  
Offie P Soldin ◽  
Steven J Soldin

Abstract Background: Accurate measurement of free thyroid hormones is important for managing thyroid disorders. Ultrafiltration liquid chromatography tandem mass spectrometry (LC-MS/MS) can reliably measure the concentrations of small molecules, including thyroid hormones. Our study was designed to compare free thyroid hormone measurements performed with immunoassay and LC-MS/MS. Methods: We studied the performance of LC-MS/MS in 4 different populations comprising pediatric patients, euthyroid adults, and healthy nonpregnant and pregnant women. The samples obtained from each population numbered 38, 200, 28, and 128, respectively. Free thyroxine, free triiodothyronine, and thyroid-stimulating hormone (TSH) concentrations were documented. Results: LC-MS/MS measurement of free thyroid hormones provided better correlation with log-transformed serum TSH in each population and also the populations combined. The correlations between free thyroxine measured by LC-MS/MS and log TSH in the pediatric outpatients and healthy adults were −0.90 and −0.77, respectively. The correlations for immunoassay were −0.82 and −0.48. The correlations between free triiodothyronine measured by LC-MS/MS and TSH for both pediatric and healthy adult populations were −0.72 and −0.68, respectively. Conclusions: Free thyroid hormone concentrations measured by LC-MS/MS correlate to a greater degree with log TSH values compared to concentrations measured by immunoassay. This correlation was maintained across the patient populations we studied and may reflect the accuracy and specificity of LC-MS/MS. The superior ability of LC-MS/MS to enable documentation of the well-known thyroid hormone–TSH relationship supports the use of this measurement technique in a variety of clinical situations.


2011 ◽  
Vol 33 (4) ◽  
pp. 691-698 ◽  
Author(s):  
A. Renne ◽  
L. Luo ◽  
J. Jarow ◽  
W. W. Wright ◽  
T. R. Brown ◽  
...  

2018 ◽  
Vol 15 (1) ◽  
pp. 17-23
Author(s):  
Vulli Srinandan ◽  
Krishnaveni Nagappan ◽  
Sonam Patel ◽  
Karthik Yamjala ◽  
Gowramma Byran ◽  
...  

Background: Pantoprazole (PTZ) and Levosulpiride (LS) were proven as effective agents for the treatment of Gastro-Esophageal Reflux Disease (GERD). It is a complex motor disorder that results in regurgitation of the gastric contents into the lower esophagus with consequent symptoms such as heart burn, retrosternal pain, dysphagia and belching. Methods: A rapid, sensitive, selective and specific liquid chromatography- electro spray ionization tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous quantification of Pantoprazole (PTZ) and Levosulpiride (LS) in spiked Human Plasma. The method utilized SPE as sample preparation technique and the analysis was carried out on a HPLC system utilizing electro spray ionization as interface and triple quadrupole mass analyzer for quantification in MRM possitive mode. Iloperidone was used as internal standard (IS). Chromatographic separation was performed on a Phenomenex C-18 Column (4.6 mm x 50 mm, 5µ) with an isocratic elution mode utilizing a mobile phase composition of Solution containing a mixture of 70 volumes of acetonitrile: 30 volumes of methanol and 10mM ammonium formate (pH 4.0) at the ratio of 80:20 % v/v. The flow rate was maintained at 0.3 mL/min. Results: PTZ, LS and IS were detected and quantified with proton adducts at m/z 383.37→200.00, m/z 341.42→112.15 and 426.48→261.00 respectively. The linearity and range was established by fortifying blank plasma samples in the concentration range of 3.5-2000 ng/mL for PTZ and 3.0-2400 ng/mL for LS. The correlation coefficient (r2) was found to be ≥ 0.993 for PTZ and (r2) ≥ 0.990 for LS. The lower limit of quantification for PTZ was 3.5 ng/mL and LS was 3.0 ng/mL. The intra and inter day precision and accuracy for PTZ and LS were within the limits fulfilling the international acceptance criteria. PTZ and LS were found to be stable throughout three freeze-thaw cycles, bench top and short term stability studies. Conclusion: The proposed validated LC-MS/MS method offers a sensitive quantification of PTZ and LS in spiked human plasma and can be utilized for the quantification of PTZ and LS in real-time samples.


Sign in / Sign up

Export Citation Format

Share Document