scholarly journals Effectiveness of a hospital-wide infection control programme on the incidence of healthcare-associated infections and associated severe sepsis and septic shock: a prospective interventional study

2019 ◽  
Vol 25 (4) ◽  
pp. 462-468 ◽  
Author(s):  
S. Hagel ◽  
K. Ludewig ◽  
M.W. Pletz ◽  
J. Frosinski ◽  
A. Moeser ◽  
...  
2018 ◽  
Vol 33 (5) ◽  
Author(s):  
Anne L. Armour ◽  
Mark E. Patrick ◽  
Zelda Reddy ◽  
Wilbert Sibanda ◽  
Logandran Naidoo ◽  
...  

Background: Healthcare-associated infections are an important cause of morbidity and mortality globally. Grey’s Hospital introduced an Infection Control Programme in August 2016, which included Best Care Always bundles for reducing the occurrence of central line-associated bloodstream infections, catheter-associated urinary tract infections and ventilatorassociated pneumonia. Methods: An observational before–after quasi-experiment was conducted retrospectively reviewing healthcare-associated infection rates in the Grey’s Hospital paediatric intensive care unit a year prior to (August 2015 to July 2016) and after (September 2016 to August 2017) implementation of an Infection Control Programme.Results: There was an absolute decrease in healthcare-associated infection from 102 to 81 and a statistically significant decrease in bloodstream infections per 1 000 central venous catheter days from 36/1 000–15/1 000 after intervention (RR 0.42, 95% CI 0.23–0.79, p = 0.004). The rate of healthcare-associated infection decreased from 23/100 admissions prior to the intervention to 20/100 admissions after the intervention (RR 0.87, 95% CI 0.51–1.48, p = 0.61) and from 40/1 000 patient days to 32/1 000 patient days (RR 0.80, 95% CI 0.51–1.26, p = 0.34). Reductions in healthcare-associated infection were also seen in bloodstream infections and urinary tract infections.Conclusion: The observed downward trend in overall healthcare-associated infections, bloodstream infections and urinary tract infections did not reach statistical significance except for bloodstream infections per 1 000 central venous catheter days. Further research or audit is needed to ascertain reasons for this less than expected decrease in healthcare-associated infections. In the meantime, meticulous adherence to bundles should be encouraged.


2015 ◽  
Vol 37 (4) ◽  
pp. 483-485
Author(s):  
Sarah B. Klieger ◽  
Julie C. Fitzgerald ◽  
Scott L. Weiss ◽  
Fran Balamuth ◽  
Eva Teszner ◽  
...  

MedPharmRes ◽  
2018 ◽  
Vol 2 (3) ◽  
pp. 27-32
Author(s):  
Bien Le ◽  
Dai Huynh ◽  
Mai Tuan ◽  
Minh Phan ◽  
Thao Pham ◽  
...  

Objectives: to evaluate the fluid responsiveness according to fluid bolus triggers and their combination in severe sepsis and septic shock. Design: observational study. Patients and Methods: patients with severe sepsis and septic shock who already received fluid after rescue phase of resuscitation. Fluid bolus (FB) was prescribed upon perceived hypovolemic manifestations: low central venous pressure (CVP), low blood pressure, tachycardia, low urine output (UOP), hyperlactatemia. FB was performed by Ringer lactate 500 ml/30 min and responsiveness was defined by increasing in stroke volume (SV) ≥15%. Results: 84 patients were enrolled, among them 30 responded to FB (35.7%). Demographic and hemodynamic profile before fluid bolus were similar between responders and non-responders, except CVP was lower in responders (7.3 ± 3.4 mmHg vs 9.2 ± 3.6 mmHg) (p 0.018). Fluid response in low CVP, low blood pressure, tachycardia, low UOP, hyperlactatemia were 48.6%, 47.4%, 38.5%, 37.0%, 36.8% making the odd ratio (OR) of these triggers were 2.81 (1.09-7.27), 1.60 (0.54-4.78), 1.89 (0.58-6.18), 1.15 (0.41-3.27) and 1.27 (0.46-3.53) respectively. Although CVP < 8 mmHg had a higher response rate, the association was not consistent at lower cut-offs. The combination of these triggers appeared to raise fluid response but did not reach statistical significance: 26.7% (1 trigger), 31.0% (2 triggers), 35.7% (3 triggers), 55.6% (4 triggers), 100% (5 triggers). Conclusions: fluid responsiveness was low in optimization phase of resuscitation. No fluid bolus trigger was superior to the others in term of providing a higher responsiveness, their combination did not improve fluid responsiveness as well.


Sign in / Sign up

Export Citation Format

Share Document