Beam penumbra reduction of Gamma Knife machine model 4C using Monte Carlo simulation

2020 ◽  
Vol 188 ◽  
pp. 105261
Author(s):  
Atefeh Mahmoudi ◽  
Ghazale Geraily ◽  
Tahereh Hadisinia ◽  
Alireza Shirazi ◽  
Milad Najafzadeh
2018 ◽  
Vol 18 (1) ◽  
pp. 82-87 ◽  
Author(s):  
Atefeh Mahmoudi ◽  
Alireza Shirazi ◽  
Ghazale Geraily ◽  
Tahereh Hadisi nia ◽  
Masoume Bakhshi ◽  
...  

AbstractBackgroundOne of the stereotactic radiosurgery techniques is Gamma Knife radiosurgery, in which intracranial lesions that are inaccessible or inappropriate for surgery are treated using 201 cobalt-60 sources in one treatment session. In this conformal technique, the penumbra width, which results in out-of-field dose in tumour-adjacent normal tissues should be determined accurately. The aim of this study is to calculate the penumbra widths of single and 201 beams for different collimator sizes of Gamma Knife machine model 4C using EGSnrc/BEAMnrc Monte Carlo simulation code and comparison the results with EBT3 film dosimetry data.Methods and materialsIn this study, simulation of Gamma Knife machine model 4C was performed based on the Monte Carlo codes of EGSnrc/BEAMnrc. To investigate the physical penumbra width (80−20%), the single beam and 201 beams profiles were obtained using EGSnrc/DOSXYZnrc code and EBT3 films located at isocentre point in a spherical Plexiglas head phantom.ResultsBased on the results, the single beam penumbra widths obtained from simulation data for 4, 8, 14 and 18 mm collimator sizes alongXaxis were 0·75, 0·77, 0·90 and 0·92 mm, respectively. The data for 201 beams obtained from simulation were 2·61, 4·80, 7·92 and 9·81 mm alongXaxis and 1·31, 1·60, 1·91 and 2·14 mm alongZaxis and from film dosimetry were 3·21, 4·90, 8·00 and 10·61 mm alongXaxis and 1·22, 1·69, 2·01 and 2·25 mm alongZaxis, respectively.ConclusionThe differences between measured and simulated penumbra widths are in an acceptable range. However, for more precise measurement in the penumbra region in which dose gradient is high, Monte Carlo simulation is recommended.


2020 ◽  
Vol 65 (1) ◽  
pp. 54-58
Author(s):  
T. Medjadj ◽  
A. Ksenofontov ◽  
A. Dalechina

Purpose: To develop an effective method of Monte Carlo simulation of the GammaKnife Perfexion system by rotating particles in the phase space file (PSF). This method does not require simulating of all 192 sources that are distributed in the conical form of the Perfexion collimator. The simulation was performed only for 5 out of 192 sources for each collimator size. Material and methods: Monte Carlo simulation of dose distribution for previous models of GammaKnife system requires phase space file for only one source, since this phase space is identical for all the 201 sources. The Perfexion model is more complex due to the non-coaxial positions of the sources and the complexity of the collimator system itself. In this work, we present an effective method to simulate the Perfexion model using a phase space file. Penelope Monte Carlo code was used to perform this simulation. In this method, the PSF was obtained for one source in each ring, resulting in five files for each collimator size. PSF for other sources were created by azimuthal redistribution of particles, in the obtained PSF, by rotation around the Z-axis. The phase space files of the same ring were then stored together in a single file. Results: The paper presented MC simulation using the azimuthal redistribution of particles in the phase space file by rotation around the Z-axis. The simulation has been validated comparing the dose profiles and output factors with the data of the algorithm TMR10 planning system Leksell Gamma Plan (LGP) in a homogeneous environment. The acceptance criterion between TMR10 and Monte Carlo calculations for the profiles was based on the gamma index (GI). Index values more than one were not detected in all cases, which indicates a good agreement of results. The differences between the output factors obtained in this work and the TMR10 data for collimators 8 mm and 4 mm are 0.74 and 0.73 %, respectively. Conclusion: In this work successfully implemented an effective method of simulating the Leksell Gamma knife Perfexion system. The presented method does not require modeling for all 192 sources distributed in the conical form of the Perfexion collimator. The simulation was performed for only five sources for each collimator and their files PSF were obtained. These files were used to create the PSF files for other sources by azimuthal redistribution of particles, in these files, by rotation around the Z-axis providing correct calculations of dose distributions in a homogeneous medium for 16, 8 and 4 mm collimators.


2002 ◽  
Vol 47 (12) ◽  
pp. 1995-2011 ◽  
Author(s):  
Vadim Moskvin ◽  
Colleen DesRosiers ◽  
Lech Papiez ◽  
Robert Timmerman ◽  
Marcus Randall ◽  
...  

2014 ◽  
Vol 41 (6Part21) ◽  
pp. 367-367
Author(s):  
G Mora ◽  
O Chibani ◽  
J Li ◽  
C Ma

2018 ◽  
Vol 73 (12) ◽  
pp. 1814-1820 ◽  
Author(s):  
Thomas Schaarschmidt ◽  
Tae Hoon Kim ◽  
Yong Kyun Kim ◽  
Hye Jeong Yang ◽  
Hyun-Tai Chung