voxel size
Recently Published Documents


TOTAL DOCUMENTS

254
(FIVE YEARS 98)

H-INDEX

28
(FIVE YEARS 3)

2022 ◽  
Vol 12 (3) ◽  
pp. 564-568
Author(s):  
Ming Lei ◽  
Junjian Zhang ◽  
Dongmei Wu

<sec> <title>Objective:</title> By using amplitude of low-frequency fluctuations (ALFF) we have analyzed activationsin brain regions at different phases in migraineurs. </sec> <sec> <title>Methods:</title> Participants included 41 patients with migraine, 19 in episode and 22 in interictal phase, and 22 controls in the healthy condition. To analyze the brain function of patients and controls, ALFF was used for performing the post-processing in the resting state by scores of Montreal Cognitive Assessment (MoCA) scale, Mini-Mental State Examination (MMSE), Hamilton Anxiety Rating Scale (HAM-A) and Hamilton Depression Rating Scale (HAM-D). </sec> <sec> <title>Results:</title> The comparison between groups of patients with migraine in the episode or interictal phases, and healthy controls showed that both episode and interictal migraine groups had the similar HAM-A and HAM-D scores (P > 0.05), but higher than that in controls (P < 0.01). For ALFF values of Episode and Interictal groups, the Montreal Neurological Institute (MNI) coordinates of the decreased ALFF were (−9, 42, 9), the voxel size = 215, including the bilateral anterior cingulate cortex (ACC), T =−4.15, without significant differences. Patients in Interictal group were with a stronger activation at MNI coordinates (12, 51, 12), in the bilateral ACC, voxel size = 90, T =3.87. </sec> <sec> <title>Conclusion:</title> ACC plays an adaptive, regulatory role in migraine and is related to multiple brain regions, which may mediate activation through descending anti-nociceptive pathways. ACC is related to opioid receptor and glutamate excitatory regulation. </sec>


Author(s):  
Min Hu ◽  
Anders Olsson ◽  
Stephen Hall ◽  
Thomas Seifert

AbstractThe connection between branch and trunk in a tree must be strong enough to transfer all loads acting on the branch, and it is well known that such branch-stem connections are indeed very strong. In this paper, X-ray computer tomography is employed to investigate the local fibre orientation in the close surrounding of a knot in a Norway spruce specimen to better understand the origins of the mechanical strength of the branch-trunk connection. First, a wood specimen containing an entire knot from pith to bark was imaged with a voxel size of 52 µm. Subsequently, smaller specimens were cut from this original specimen and imaged again with increasingly higher resolution over four levels. With the highest resolution level (2.6 µm voxel size), the tracheids with smallest lumen were successfully traced. The results revealed how the direction of the fibre paths that start below the knot curve around it as the paths progress upwards to the region just above the knot, where the paths divide into two: one set of paths integrating with the knot on its top side and the other set continuing up along the trunk. Fibres that integrate with the knot at its top follow paths just before they continue into the knot, with a radius of curvature of only about 1 mm in both vertical and horizontal directions. No abrupt change of fibre pattern between latewood and earlywood is observed; rather, a continuous change of fibre direction across annual layers can be seen. The detailed characterisation of the local fibre structure around the knot provides new data that can explain the remarkable strength of the branch-trunk connection.


Physics ◽  
2021 ◽  
Vol 3 (4) ◽  
pp. 1254-1267
Author(s):  
Martin Bruschewski ◽  
Sam Flint ◽  
Sid Becker

Studies that use magnetic resonance velocimetry (MRV) to assess flows through porous media require a sufficiently small voxel size to determine the velocity field at a sub-pore scale. The smaller the voxel size, the less information is lost through the discretization. However, the measurement uncertainty and the measurement time are increased. Knowing the relationship between voxel size and measurement accuracy would help researchers select a voxel size that is not too small in order to avoid unnecessary measurement effort. This study presents a systematic parameter study with a low-Reynolds-number flow of a glycerol–water mixture sent through a regularly periodic porous matrix with a pore size of 5 mm. The matrix was a 3-dimensional polymer print, and velocity-encoded MRV measurements were made at 15 different voxel sizes between 0.42 mm and 4.48 mm. The baseline accuracy of the MRV velocity data was examined through a comparison with a computational fluid dynamics (CFD) simulation. The experiment and simulation show very good agreement, indicating a low measurement error. Starting from the smallest examined voxel size, the influence of the voxel size on the accuracy of the velocity data was then examined. This experiment enables us to conclude that a voxel size of 0.96 mm, which corresponds to 20% of the pore size, is sufficient. The volume-averaged results do not change below a voxel size of 20% of the pore size, whereas systematic deviations occur with larger voxels. The same trend is observed with the local velocity data. The streamlines calculated from the MRV velocity data are not influenced by the voxel size for voxels of up to 20% of the pore size, and even slightly larger voxels still show good agreement. In summary, this study shows that even with a relatively low measurement resolution, quantitative 3-dimensional velocity fields can be obtained through porous flow systems with short measurement times and low measurement uncertainty.


2021 ◽  
pp. 146531252110661
Author(s):  
Gaston F Coutsiers Morell ◽  
Yuli Berlin-Broner ◽  
Carlos Flores-Mir ◽  
Giseon Heo

Objective: To quantify tooth volume differences from extracted teeth when using three different three-dimensional (3D) computed tomography (CT)-based imaging modalities. Design: Ex vivo study. Setting: Laboratory and clinics of the University of Alberta. Methods: Cone-beam CT (CBCT) of 12 extracted teeth were scanned using 0.25- and 0.30-mm voxel size from CBCT and a 0.06-mm voxel size from micro-CT (reference standard). 3D reconstructions for each tooth from each imaging modality were made through the software ITK-SNAP®. The mean volume differences between each pair of scanning modalities were calculated and then compared and analysed through a repeated measures ANOVA. Results: The average overestimations of the teeth volume were 15.2% for the high-resolution CBCT and 28.1% for the low-resolution CBCT compared to micro-CT measurements. The differences in absolute volume were 81.6 mm3 and 152.8 mm3, respectively. All differences were statistically significant ( P < 0.05). Conclusions: Orthodontists and researchers who assess root resorption through CBCT imaging should be aware that the depicted volumes may likely be overestimating tooth volume and camouflaging real root volumetric treatment changes.


Author(s):  
Ricardo Kehrwald ◽  
Hebert Sampaio de Castro ◽  
Samira Salmeron ◽  
Ricardo Alves Matheus ◽  
Gustavo Machado Santaella ◽  
...  

Abstract Objective This study was developed to evaluate the influence of voxel size on bone measurements for implant planning. Materials and Methods The research was performed by using edentulous synthetic human mandibles with different levels of bone resorption. For each mandible, height and bone thickness were measured with a digital caliper. The PaX-i3d device was used to acquire the volumes of the five mandibles, with 50kVp, 4 mA, and a voxel size of 0.08 mm. After the acquisition, the images were reconstructed in the software CS three-dimensional Imaging, with four different sizes of voxels: 0.1, 0.2, 0.3, and 0.4 mm. All volumes were analyzed by a single evaluator who performed measurements to obtain bone height and thickness, using the reference points that were considered in obtaining the gold standard. The data were analyzed by ANOVA with a significance level of 5%. Results There was no significant difference in the measurements obtained with different voxel sizes, both for bone height measurements and bone thickness. There was no statistically significant difference in measurements in thickness in comparison to the gold standard. Conclusion When necessary, to measure height and bone thickness, it is possible to recommend voxel images of larger size (0.40 mm) without compromising the quality of the patient's clinical planning.


PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0260245
Author(s):  
Douglas D. Burman

Studies of the hippocampus use smaller voxel sizes and smoothing kernels than cortical activation studies, typically using a multivoxel seed with specified radius for connectivity analysis. This study identified optimal processing parameters for evaluating hippocampal connectivity with sensorimotor cortex (SMC), comparing effectiveness by varying parameters during both activation and connectivity analysis. Using both 3mm and 4mm isovoxels, smoothing kernels of 0-10mm were evaluated on the amplitude and extent of motor activation and hippocampal connectivity with SMC. Psychophysiological interactions (PPI) identified hippocampal connectivity with SMC during volitional movements, and connectivity effects from multivoxel seeds were compared with alternate methods; a structural seed represented the mean connectivity map from all voxels within a region, whereas a functional seed represented the regional voxel with maximal SMC connectivity. With few exceptions, the same parameters were optimal for activation and connectivity. Larger isovoxels showed larger activation volumes in both SMC and the hippocampus; connectivity volumes from structural seeds were also larger, except from the posterior hippocampus. Regardless of voxel size, the 10mm smoothing kernel generated larger activation and connectivity volumes from structural seeds, as well as larger beta estimates at connectivity maxima; structural seeds also produced larger connectivity volumes than multivoxel seeds. Functional seeds showed lesser effects from voxel size and smoothing kernels. Optimal parameters revealed topography in structural seed connectivity along both the longitudinal axis and mediolateral axis of the hippocampus. These results indicate larger voxels and smoothing kernels can improve sensitivity for detecting both cortical activation and hippocampal connectivity.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Woo Hyeon Lim ◽  
Joon Sik Park ◽  
Jaeseok Park ◽  
Seung Hong Choi

AbstractTemporal and spatial resolution of dynamic contrast-enhanced MR imaging (DCE-MRI) is critical to reproducibility, and the reproducibility of high-resolution (HR) DCE-MRI was evaluated. Thirty consecutive patients suspected to have brain tumors were prospectively enrolled with written informed consent. All patients underwent both HR-DCE (voxel size, 1.1 × 1.1 × 1.1 mm3; scan interval, 1.6 s) and conventional DCE (C-DCE; voxel size, 1.25 × 1.25 × 3.0 mm3; scan interval, 4.0 s) MRI. Regions of interests (ROIs) for enhancing lesions were segmented twice in each patient with glioblastoma (n = 7) to calculate DCE parameters (Ktrans, Vp, and Ve). Intraclass correlation coefficients (ICCs) of DCE parameters were obtained. In patients with gliomas (n = 25), arterial input functions (AIFs) and DCE parameters derived from T2 hyperintense lesions were obtained, and DCE parameters were compared according to WHO grades. ICCs of HR-DCE parameters were good to excellent (0.84–0.95), and ICCs of C-DCE parameters were moderate to excellent (0.66–0.96). Maximal signal intensity and wash-in slope of AIFs from HR-DCE MRI were significantly greater than those from C-DCE MRI (31.85 vs. 7.09 and 2.14 vs. 0.63; p < 0.001). Both 95th percentile Ktrans and Ve from HR-DCE and C-DCE MRI could differentiate grade 4 from grade 2 and 3 gliomas (p < 0.05). In conclusion, HR-DCE parameters generally showed better reproducibility than C-DCE parameters, and HR-DCE MRI provided better quality of AIFs.


2021 ◽  
Author(s):  
R. Patrick Xian ◽  
Claire L. Walsh ◽  
Stijn E. Verleden ◽  
Willi L. Wagner ◽  
Alexandre Bellier ◽  
...  

Technological advancements in X-ray imaging using bright and coherent synchrotron sources now allows to decouple sample size and resolution, while maintaining high sensitivity to the microstructure of soft, partially dehydrated tissues. The recently developed imaging technique, hierarchical phase-contrast tomography, is a comprehensive approach to address the challenge of organ-scale (up to tens of centimeters) soft tissue imaging with resolution and sensitivity down to the cellular level. Using this technique, we imaged ex vivo an entire human left lung at an isotropic voxel size of 25.08 μm along with local zooms down to 6.05 - 6.5 μm and 2.45 - 2.5 μm in voxel size. The high tissue contrast offered by the fourth-generation synchrotron source at the European Synchrotron Radiation Facility reveals complex multiscale anatomical constitution of the human lung from the macroscopic (centimeter) down to the microscopic (micrometer) scale. The dataset provides complete organ-scale 3D information of the secondary pulmonary lobules and delineates the microstructure of lung nodules with unprecedented detail.


PLoS ONE ◽  
2021 ◽  
Vol 16 (11) ◽  
pp. e0257349
Author(s):  
David Haberthür ◽  
Eveline Yao ◽  
Sébastien F. Barré ◽  
Tiziana P. Cremona ◽  
Stefan A. Tschanz ◽  
...  

Pulmonary acini represent the functional gas-exchanging units of the lung. Due to technical limitations, individual acini cannot be identified on microscopic lung sections. To overcome these limitations, we imaged the right lower lobes of instillation-fixed rat lungs from postnatal days P4, P10, P21, and P60 at the TOMCAT beamline of the Swiss Light Source synchrotron facility at a voxel size of 1.48 μm. Individual acini were segmented from the three-dimensional data by closing the airways at the transition from conducting to gas exchanging airways. For a subset of acini (N = 268), we followed the acinar development by stereologically assessing their volume and their number of alveoli. We found that the mean volume of the acini increases 23 times during the observed time-frame. The coefficients of variation dropped from 1.26 to 0.49 and the difference between the mean volumes of the fraction of the 20% smallest to the 20% largest acini decreased from a factor of 27.26 (day 4) to a factor of 4.07 (day 60), i.e. shows a smaller dispersion at later time points. The acinar volumes show a large variation early in lung development and homogenize during maturation of the lung by reducing their size distribution by a factor of 7 until adulthood. The homogenization of the acinar sizes hints at an optimization of the gas-exchange region in the lungs of adult animals and that acini of different size are not evenly distributed in the lungs. This likely leads to more homogeneous ventilation at later stages in lung development.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
C. Riemann ◽  
L. U. Scholtz ◽  
H. B. Gehl ◽  
M. Schürmann ◽  
H. Sudhoff ◽  
...  

AbstractThe estimation of scalar electrode position is a central point of quality control during the cochlear implant procedure. Ionic radiation is a disadvantage of commonly used radiologic estimation of electrode position. Recent developments in the field of cochlear implant magnets, implant receiver magnet position, and MRI sequence usage allow the postoperative evaluation of inner ear changes after cochlear implantation. The aim of the present study was to evaluate the position of lateral wall and modiolar cochlear implant electrodes using 3 T MRI scanning. In a prospective study, we evaluated 20 patients (10× Med-El Flex 28; 5× HFMS AB and 5× SlimJ AB) with a 3 T MRI and a T2 2D Drive MS sequence (voxel size: 0.3 × 0.3 × 0.9 mm) for the estimation of the intracochlear position of the cochlear implant electrode. In all cases, MRI allowed a determination of the electrode position in relation to the basilar membrane. This observation made the estimation of 19 scala tympani electrode positions and a single case of electrode translocation possible. 3 T MRI scanning allows the estimation of lateral wall and modiolar electrode intracochlear scalar positions.


Sign in / Sign up

Export Citation Format

Share Document