Experimental study on hybrid CFRP-PU strengthening effect on RC panels under blast loading

2011 ◽  
Vol 93 (8) ◽  
pp. 2070-2082 ◽  
Author(s):  
Ju-Hyung Ha ◽  
Na-Hyun Yi ◽  
Jong-Kwon Choi ◽  
Jang-Ho Jay Kim



2018 ◽  
Vol 183 ◽  
pp. 02008 ◽  
Author(s):  
Pavlo Krainskyi ◽  
Yaroslav Blikharskyy ◽  
Roman Khmil ◽  
Zinoviy Blikharskyy

The need of structural retrofitting and strengthening of different buildings, engineering structures or their elements is always present. Among the main reasons are demages and material deterioration due to aging, improper maintenance or physical damages; planed repairs; reconstruction or extension of the building; technical modification or complete change of operations inside the building or the structure, etc. In some cases operation of the building during retrofitting or strengthening of its structures has to be partially or fully stopped. In other cases the strengthening process takes place while the building is still operational which means that structures are strengthened under service loads. The main goal of this research is to determine the strengthening effect of reinforced concrete jacketing applied to columns under service load level. For that the experimental study of six reinforced concrete columns were carried out: four reference columns, both strengthened by jacketing and unstrengthened and two strengthened under service load. The main results of the research are presented.



2019 ◽  
Vol 134 ◽  
pp. 103370
Author(s):  
Xiangshao Kong ◽  
Hu Zhou ◽  
Cheng Zheng ◽  
Haibao Liu ◽  
Weiguo Wu ◽  
...  




2020 ◽  
Vol 1507 ◽  
pp. 032039
Author(s):  
J Wang ◽  
L J Jiao ◽  
J S Li ◽  
N Li ◽  
Z G Tao ◽  
...  


2010 ◽  
Vol 163-167 ◽  
pp. 3580-3585
Author(s):  
Yuan Che ◽  
Qing Li Wang ◽  
Yong Bo Shao ◽  
Hai Tao Mu

Overall 12 specimens were experimentally investigated in this paper to study the hysteretic behaviors of the concrete-filled square CFRP-steel tubular (S-CFRP-CFST) beam-columns. The test results indicated that CFRP can provide transverse confinement effect and longitudinal strengthening effect for the concrete filled square steel tubular (S-CFST) beam-columns effectively and the local buckling of the steel tube is deferred. The hysteretic load-deflection curves and the hysteretic moment-curvature curves at the mid-span of all the specimens are generally plump, and it shows these specimens have good hysteretic performance. In the later loading period, the load bearing capacity drops.



2016 ◽  
Vol 105 ◽  
pp. 67-81 ◽  
Author(s):  
Pan Zhang ◽  
Yuansheng Cheng ◽  
Jun Liu ◽  
Yong Li ◽  
Changzai Zhang ◽  
...  


2021 ◽  
Vol 26 (2) ◽  
pp. 04020124
Author(s):  
Lu Liu ◽  
Zhouhong Zong ◽  
Zhongguo John Ma ◽  
HaiMin Qian ◽  
Lu Gan




Sign in / Sign up

Export Citation Format

Share Document