Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography

2015 ◽  
Vol 70 (11) ◽  
pp. 1244-1251 ◽  
Author(s):  
A. Meier ◽  
M. Wurnig ◽  
L. Desbiolles ◽  
S. Leschka ◽  
T. Frauenfelder ◽  
...  
PLoS ONE ◽  
2016 ◽  
Vol 11 (12) ◽  
pp. e0167214 ◽  
Author(s):  
Andreas Meier ◽  
Kai Higashigaito ◽  
Katharina Martini ◽  
Moritz Wurnig ◽  
Burkhardt Seifert ◽  
...  

2020 ◽  
Vol 2 (5) ◽  
pp. e200428 ◽  
Author(s):  
Carole A Ridge ◽  
Sujal R Desai ◽  
Nidhish Jeyin ◽  
Ciara Mahon ◽  
Dione L Lother ◽  
...  

2020 ◽  
Vol 30 (5) ◽  
pp. 2535-2542 ◽  
Author(s):  
Ramandeep Singh ◽  
Ryan Zipan Nie ◽  
Fatemeh Homayounieh ◽  
Bernhard Schmidt ◽  
Thomas Flohr ◽  
...  

2019 ◽  
Vol 29 (9) ◽  
pp. 4603-4612 ◽  
Author(s):  
Lukas Lenga ◽  
Franziska Trapp ◽  
Moritz H. Albrecht ◽  
Julian L. Wichmann ◽  
Addison A. Johnson ◽  
...  

2020 ◽  
pp. 028418512093324
Author(s):  
Gyeong Min Kim ◽  
Ki Seok Choo ◽  
Jin Hyeok Kim ◽  
Jae-Yeon Hwang ◽  
Chan Kyu Park ◽  
...  

Background The coronary venous system is frequently used as an entry route to the heart and treatment modalities for many cardiac diseases and many procedures. Consequently, evaluation of the coronary venous system and understanding cardiac vein anatomy is crucial. Purpose To determine the optimal image set in a comparison of noise-optimized linearly blended images (F_0.6) and noise-optimized virtual monoenergetic images (VMI+) evaluated by dual-energy computed tomography (DECT) for cardiac vein assessment. Material and Methods Thirty-four patients (mean age 58.2 ± 14.2 years) who underwent DECT due to chest pain were enrolled. Images were post-processed with the F_0.6, and VMI+ algorithms at energy levels in the range of 40–100 keV in 10-keV increments. Enhancement (HU), noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were objectively measured at two points in the great cardiac vein by consensus of two radiologists. Two blinded observers evaluated the subjective image quality of the great cardiac vein on a 4-point scale. Results HU, noise, and SNR peaked at 40 keV VMI+ ( P < 0.05) among 50–100 keV VMI+. CNR peaked at 100 keV VMI+; however, there were no significant differences compared to CNR images processed at 40–90 keV VMI+. HU and noise were significantly higher in 40 keV VMI+ than F_0.6 images; however, both SNR and CNR were significantly higher in F_0.6 images. An assessment of subjective vein delineation revealed that F_0.6 images had the highest scores Conclusion F_0.6 images were superior to VMI+ and provided the optimal image set for cardiac vein assessment.


Sign in / Sign up

Export Citation Format

Share Document