Poly(acrylates) showing critical fluorescence change in response to heat

2021 ◽  
pp. 109647
Author(s):  
Young-Jae Jin ◽  
Heesang Kim ◽  
Giseop Kwak
Keyword(s):  
2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Shengqiang Fan ◽  
Genevieve H. Dennison ◽  
Nicholas FitzGerald ◽  
Paul L. Burn ◽  
Ian R. Gentle ◽  
...  

AbstractA common feature of fluorescent sensing materials for detecting chemical warfare agents (CWAs) and simulants is the presence of nitrogen-based groups designed to nucleophilically displace a phosphorus atom substituent, with the reaction causing a measurable fluorescence change. However, such groups are also basic and so sensitive to acid. In this study we show it is critical to disentangle the response of a candidate sensing material to acid and CWA simulant. We report that pyridyl-containing sensing materials designed to react with a CWA gave a strong and rapid increase in fluorescence when exposed to Sarin, which is known to contain hydrofluoric acid. However, when tested against acid-free diethylchlorophosphate and di-iso-propylfluorophosphate, simulants typically used for evaluating novel G-series CWA sensors, there was no change in the fluorescence. In contrast, simulants that had been stored or tested under a standard laboratory conditions all led to strong changes in fluorescence, due to acid impurities. Thus the results provide strong evidence that care needs to be taken when interpreting the results of fluorescence-based solid-state sensing studies of G-series CWAs and their simulants. There are also implications for the application of these pyridyl-based fluorescence and other nucleophilic/basic sensing systems to real-world CWA detection.


1976 ◽  
Vol 158 (2) ◽  
pp. 295-305 ◽  
Author(s):  
N Gains ◽  
A P Dawson

A comparison of the fluorescence change on the addition of 8-anilinonaphthalene-1-sulphonate to succinate-energized submitochondrial particles with that on the addition of succinate to submitochondrial particles incubated with 8-anilinonaphthalene-1-sulphonate shows that these changes in fluorescence may be explained solely in terms of 8-anilinonaphthalene-1-sulphonate binding. This comparison does not support the proposal of an 8-anilinonaphthalene-1-sulphonate-monitored change in the conformation of submitochondrial-particle membranes [Brocklehurst, Freedman, Hancock & Radda (1970) Biochem. J.116, 721-731]. The biphasic nature of the decrease in fluorescence, which was found to follow the addition of uncoupler to submitochondrial particles incubated with ATP or succinate, or of antimycin A to submitochondrial particles incubated with succinate, does not support the existence of ‘aplectic’ and ‘symplectic’ states of the mitochondrial membrane [Barrett-Bee & Radda (1972) Biochim, Biophys. Acta 267, 211-215].


Tetrahedron ◽  
2012 ◽  
Vol 68 (13) ◽  
pp. 2778-2783 ◽  
Author(s):  
Misae Kanai ◽  
Tomoya Hirano ◽  
Isao Azumaya ◽  
Iwao Okamoto ◽  
Hiroyuki Kagechika ◽  
...  

2020 ◽  
Vol 54 (3 (253)) ◽  
pp. 261-264
Author(s):  
M.A. Shahinyan ◽  
N.H. Petrosyan ◽  
A.P. Antonyan

The interaction of methyl violet (MV) with human serum albumin (HSA) has been studied, using the fluorescence spectroscopy method. It was shown that MV chnages the own fluorescence of HSA. It was also shown that MV does not induce any conformational change in the structure of HSA, since there is no change of the wavelength of HSA fluorescence intensity maximum. MV binds to HSA, near to fluorescing tryptophan, which in the hydrophilic environment, and changes the own fluorescence of the protein.


2008 ◽  
Vol 25 (2) ◽  
pp. 139-153 ◽  
Author(s):  
VICTORIA P. CONNAUGHTON ◽  
RALPH NELSON ◽  
ANNA M. BENDER

AbstractTo refine inhibitory circuitry models for ON and OFF pathways in zebrafish retina, GABAergic properties of zebrafish bipolar cells were studied with two techniques: whole cell patch responses to GABA puffs in retinal slice, and voltage probe responses in isolated cells. Retinal slices documented predominantly axon terminal responses; isolated cells revealed mainly soma-dendritic responses. In the slice, GABA elicited a conductance increase, GABA responses were more robust at axon terminals than dendrites, and Erev varied with [Cl−]in. Axon terminals of ON- and OFF-type cells were similarly sensitive to GABA (30–40 pA peak current); axotomized cells were unresponsive. Bicuculline-sensitive, picrotoxin-sensitive, and picrotoxin-insensitive components were identified. Muscimol was as effective as GABA; baclofen was ineffective. Isolated bipolar cells were either intact or axotomized. Even in cells without an axon, GABA or muscimol (but not baclofen) hyperpolarized dendritic and somatic regions, suggesting significant distal expression. Median fluorescence change for GABA was −0.22 log units (∼ −16 mV); median half-amplitude dose was 0.4 μM. Reduced [Cl−]out blocked GABA responses. GABA hyperpolarized isolated ON-bipolar cells; OFF-cells were either unresponsive or depolarized. Hyperpolarizing GABA responses in isolated cells were bicuculline and TPMPA insensitive, but blocked or partially blocked by picrotoxin or zinc. In summary, axon terminals contain bicuculline-sensitive GABAA receptors and both picrotoxin-sensitive and insensitive GABAC receptors. Dendritic processes express zinc- and picrotoxin-sensitive GABAC receptors.


2020 ◽  
Vol 59 (37) ◽  
pp. 16195-16201 ◽  
Author(s):  
Shotaro Hayashi ◽  
Fumitaka Ishiwari ◽  
Takanori Fukushima ◽  
Shohei Mikage ◽  
Yutaka Imamura ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document