The exposure risk of typical VOCs to the human beings via inhalation based on the respiratory deposition rates by proton transfer reaction-time of flight-mass spectrometer

2020 ◽  
Vol 197 ◽  
pp. 110615 ◽  
Author(s):  
Yi Yang ◽  
Hao Luo ◽  
Ranran Liu ◽  
Guiying Li ◽  
Yingxin Yu ◽  
...  
2016 ◽  
Vol 52 (1) ◽  
pp. 30-35 ◽  
Author(s):  
Christof Stönner ◽  
Bettina Derstroff ◽  
Thomas Klüpfel ◽  
John N. Crowley ◽  
Jonathan Williams

2014 ◽  
Vol 7 (7) ◽  
pp. 6565-6593 ◽  
Author(s):  
C. Warneke ◽  
P. R. Veres ◽  
S. M. Murphy ◽  
J. Soltis ◽  
R. A. Field ◽  
...  

Abstract. Here we compare volatile organic compound (VOC) measurements using a standard Proton-Transfer-Reaction Quadrupole Mass Spectrometer (PTR-QMS) with a new Proton-Transfer-Reaction Time Of Flight Mass Spectrometer (PTR-TOF) during the Uintah Basin Winter Ozone Study 2013 (UBWOS2013) field experiment in an oil and gas field in the Uintah Basin, Utah. The PTR-QMS uses a quadrupole, which is a mass filter that lets one mass pass at a time, whereas the PTR-TOF uses a Time Of Flight mass spectrometer, which takes full mass spectra with typical 0.1 s to 1 min integrated acquisition times. The sensitivity of the PTR-QMS in units of counts per ppbv is about a factor of 10–35 times larger than the PTR-TOF, when only one VOC is measured. The sensitivity of the PTR-TOF is mass dependent because of the mass discrimination caused by the sampling duty cycle in the orthogonal-acceleration region of the TOF. For example, the PTR-QMS on mass 33 (methanol) is 35 times more sensitive than the PTR-TOF and for masses above 120 amu less than 10 times more. If more than 10–35 compounds are measured with PTR-QMS, the sampling time per ion decreases and the PTR-TOF has higher signals per unit measuring time for most masses. For UBWOS2013 the PTR-QMS measured 34 masses in 37 s and on that time-scale the PTR-TOF is more sensitive for all masses. The high mass resolution of the TOF allows for the measurements of compounds that cannot be separately detected with the PTR-QMS, such as oxidation products from alkanes and cycloalkanes emitted by oil and gas extraction. PTR-TOF masses do not have to be pre-selected allowing for identification of unanticipated compounds. The measured mixing ratios of the two instruments agreed very well (R2 ≥ 0.92 and within 20%) for all compounds and masses monitored with the PTR-QMS.


2015 ◽  
Vol 8 (1) ◽  
pp. 411-420 ◽  
Author(s):  
C. Warneke ◽  
P. Veres ◽  
S. M. Murphy ◽  
J. Soltis ◽  
R. A. Field ◽  
...  

Abstract. Here we compare volatile organic compound (VOC) measurements using a standard proton-transfer-reaction quadrupole mass spectrometer (PTR-QMS) with a new proton-transfer-reaction time of flight mass spectrometer (PTR-TOF) during the Uintah Basin Winter Ozone Study 2013 (UBWOS2013) field experiment in an oil and gas field in the Uintah Basin, Utah. The PTR-QMS uses a quadrupole, which is a mass filter that lets one mass to charge ratio pass at a time, whereas the PTR-TOF uses a time of flight mass spectrometer, which takes full mass spectra with typical 0.1 s–1 min integrated acquisition times. The sensitivity of the PTR-QMS in units of counts per ppbv (parts per billion by volume) is about a factor of 10–35 times larger than the PTR-TOF, when only one VOC is measured. The sensitivity of the PTR-TOF is mass dependent because of the mass discrimination caused by the sampling duty cycle in the orthogonal-acceleration region of the TOF. For example, the PTR-QMS on mass 33 (methanol) is 35 times more sensitive than the PTR-TOF and for masses above 120 amu less than 10 times more. If more than 10–35 compounds are measured with PTR-QMS, the sampling time per ion decreases and the PTR-TOF has higher signals per unit measuring time for most masses. For UBWOS2013 the PTR-QMS measured 34 masses in 37 s and on that timescale the PTR-TOF is more sensitive for all masses. The high mass resolution of the TOF allows for the measurements of compounds that cannot be separately detected with the PTR-QMS, such as oxidation products from alkanes and cycloalkanes emitted by oil and gas extraction. PTR-TOF masses do not have to be preselected, allowing for identification of unanticipated compounds. The measured mixing ratios of the two instruments agreed very well (R2 ≥ 0.92 and within 20%) for all compounds and masses monitored with the PTR-QMS.


Sign in / Sign up

Export Citation Format

Share Document