Channel complexity and nitrate concentrations drive denitrification rates in urban restored and unrestored streams

2014 ◽  
Vol 73 ◽  
pp. 770-777 ◽  
Author(s):  
Alea K. Tuttle ◽  
Sara K. McMillan ◽  
Angela Gardner ◽  
Gregory D. Jennings
HortScience ◽  
1990 ◽  
Vol 25 (9) ◽  
pp. 1120G-1120
Author(s):  
J. L. Jacobs ◽  
C. T. Stephens

Several growth hormone combinations and silver nitrate concentrations were examined for their effect on regeneration of different pepper genotypes. Primary leaf explants from in vitro seedlings were cultured on a revised Murashige and Skoog medium supplemented with auxin, cytokinin and 1.6% glucose. Combinations of different concentrations of indole-3-acetic acid (IAA), 0-5 mg/l, and 6-benzylaminopurine (BAP), 0-5 mg/l, were tested to determine the most effective medium for shoot primordium formation. Experiments with IAA and BAP did not result in a specific growth hormone combination appropriate for regeneration of all genotypes tested. Of the silver nitrate concentrations tested, 10 mg/l resulted in the best shoot and leaf differentiation and reduced callus formation. Differences in organogenic response of individual genotypes were evaluated on a single regeneration medium. Whole plants were regenerated from 11 of 63 genotypes examined. Based on these experiments, a reproducible regeneration system for pepper was developed with a total of 500 plants regenerated to date.


2018 ◽  
Author(s):  
Lauren E. Koenig ◽  
◽  
William H. McDowell ◽  
Lisle E. Snyder ◽  
Jody D. Potter

CATENA ◽  
2008 ◽  
Vol 76 (1) ◽  
pp. 63-69 ◽  
Author(s):  
Zhao Zhang ◽  
Takehiko Fukushima ◽  
Peijun Shi ◽  
Fulu Tao ◽  
Yuichi Onda ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 965
Author(s):  
Xingyue Zhu ◽  
Kaixiong Yu ◽  
Xiaofan Zhu ◽  
Juan Su ◽  
Chi Wu

Nowadays, it is still a challenge for commercial nitrate sensors to meet the requirement of high accuracy in a complex water. Based on deep-ultraviolet spectral analysis and a regression algorithm, a different measuring method for obtaining the concentration of nitrate in seawater is proposed in this paper. The system consists of a deuterium lamp, an optical fiber splitter module, a reflection probe, temperature and salinity sensors, and a deep-ultraviolet spectrometer. The regression model based on weighted average kernel partial least squares (WA-KPLS) algorithm together with corrections for temperature and salinity (TSC) is established. After that, the seawater samples from Western Pacific and Aoshan Bay in Qingdao, China with the addition of various nitrate concentrations are studied to verify the reliability and accuracy of the method. The results show that the TSC-WA-KPLS algorithm shows the best results when compared against the multiple linear regression (MLR) and ISUS (in situ ultraviolet spectrophotometer) algorithms in the temperatures range of 4–25 °C, with RMSEP of 0.67 µmol/L for Aoshan Bay seawater and 1.08 µmol/L for Western Pacific seawater. The method proposed in this paper is suitable for measuring the nitrate concentration in seawater with higher accuracy, which could find application in the development of in-situ and real-time nitrate sensors.


2012 ◽  
Vol 57 (5) ◽  
pp. 1076-1095 ◽  
Author(s):  
BRIAN G. LAUB ◽  
Daniel W. BAKER ◽  
Brian P. BLEDSOE ◽  
MARGARET A. PALMER
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document