Horizontal subsurface-flow constructed wetland removal efficiency using Cyperus articulatus L.

2017 ◽  
Vol 99 ◽  
pp. 479-485 ◽  
Author(s):  
Aracelly Caselles-Osorio ◽  
Hamer Vega ◽  
Juan Camilo Lancheros ◽  
Henry Alberto Casierra-Martínez ◽  
Jose Euliser Mosquera
2010 ◽  
Vol 37 (3) ◽  
pp. 496-501 ◽  
Author(s):  
K.N. Njau ◽  
M. Renalda

A horizontal subsurface flow constructed wetland (HSSFCW) was employed to remove tannins from the effluent of a tannins extracting company. Two HSSFCW cells with hydraulic retention time (HRT) of 9 d and packed with limestone were used. One cell without macrophytes was used as a control, while the second cell was planted with Phragmites mauritianus . Results indicated that HSSFCW was capable of treating tannin wastewater that has been seeded with primary facultative pond sludge. Tannins and chemical oxygen demand (COD) removal efficiency of 95.9% and 90.6% with outlet concentration of 27 mg/L and 86 mg/L, respectively, were obtained in the planted cell; while the tannins and COD removal efficiency of 91.1% and 89.5% with outlet concentration of 57 mg/L and 96 mg/L, respectively, were obtained in the control cell.


2014 ◽  
Vol 1073-1076 ◽  
pp. 965-969 ◽  
Author(s):  
Ahmed Mohammed Osman ◽  
Xi Wu Lu

In this study, the performance treatment of horizontal subsurface flow constructed wetland (HSFCW) was evaluated. The HSFCW built as a tertiary treatment process after the biological reactors to improve the effluent quality. The HSFCW system was operated with different hydraulic loading rates (HLRs) ranged from 0.15 to 0.333 m3/ (m2.d) to assess their influence on removal efficiency. During the system operation time, the average temperature was ranged of 22.3 to 31.2 °C and pH ranges was 7.3 – 8.1. The Ipomoea aquatica (Chinese spinach) planted into HSFCW system and the growth parameters during the experimental operation observed. The Ipomoea aquatica growth parameters such as the plant height, a fresh and dry weights were monitored and measured. The influent and effluent of chemical oxygen demand (COD), ammonium nitrogen (NH4-N), total nitrogen (TN) and total phosphorus (TP) were examined. The removal efficiency for all parameters showed decreased with an increase in HLR from 0.15 to 0.333 m3/ (m2.day). The results demonstrated that the average removal efficiency of the COD, NH4-N, TN and TP during system operation is 52.9%, 64.6%, 58.2% and 72.8% respectively. These results confirm that the HSFCW has a good efficient in treatment and can be used for the nutrients and organic matter removal from the domestic wastewater.


2020 ◽  
Author(s):  
Gede H Cahyana

Activated sludge is a wastewater treatment reactor widely applied for hospital. The reactor requires a mechanical aerator as a source of oxygen. At the same time, Subsurface Flow Constructed Wetland is rarely used. Both types of reactors utilize microbes in reducing pollutants of wastewater. The role of microbes in activated sludge is taken over by microbes that grow in the root zone of Typha latifolia and Vetiver sp. Two laboratory scale reactors were made to get serial data on the performance of the two plants in treating hospital wastewater. The result, the removal efficiency of COD on Q1 = 0.13 l/h and COD on Q2 = 0.43 l/h for Typha latifolia plants were 87.71% and 67.61%. On Vetiver sp. plants were 90,07% and 68,32%. The removal efficiency of BOD5 on Q1 = 0.13 l/h and Q2 = 0.43 l/h for Typha latifolia plants were 90.00% and 71.7%. On Vetiver sp. plants were 91.69% and 73.29%. The efficiency of Total Kjeldahl Nitrogen removal (TKN) Q1 = 0.13 l/h and Q2 = 0.43 l/h for Typha latifolia plants were 91.27% and 61.54%, whereas in Vetiver sp. plants were 92.01% and 62.68%. Horizontal Subsurface Flow Constructed Wetland is capable and feasible for hospital wastewater treatment.


Author(s):  
R. Shruthi ◽  
G. P. Shivashankara

Abstract To find the effect of Hydraulic Retention Time (HRT) and seasons on the performance of horizontal subsurface flow constructed wetland (HSSF CW) in treating rural wastewater, a pilot scale unit 2.5 m × 0.4 m × 0.3 m size bed planted with a Typha latifolia and Phragmites australis was operated for a 12-month duration. During the study 2, 4, 6, 8, and 10 days of HRT were maintained in winter, summer, and rainy seasons. The removal efficiency obtained was ranges from 62.09 to 87.23% for Chemical Oxygen Demand, 69.58% to 93.32% for Biochemical Oxygen Demand5 (BOD), 31.55% to 59.89% for Ammonia Nitrogen (NH4-N), 15.18% to 52.90% for Total Kjeldahl Nitrogen (TKN), 21.02% to 50.21% for Phosphate Phosphorus (PO43− P), 19.82% to 48.23% for, Total phosphorus (TP), 74.93% to 93.10% for Faecal Coliform (FC) and 69.93% to 90.23% Total Coliform (TC). Overall, results showed that the performance of the unit was good. For statistical analysis two way ANOVA test followed by the Tukey test was used with a 95% level of significance. It was observed that the removal efficiency of the pollutants were increased with an increase in HRT. HRT of 6 days found as adequate for significant removal of organic matter (COD and BOD). Seasonal removal efficiencies followed the order of summer > rainy > winter for all the parameters, but the difference was not statistically significant.


2010 ◽  
Vol 62 (3) ◽  
pp. 603-614 ◽  
Author(s):  
G. D. Gikas ◽  
V. A. Tsihrintzis

A small-scale horizontal subsurface flow constructed wetland, located in North Greece, was designed and constructed to treat wastewater from a single-family residence. A three-year monitoring program was undertaken to evaluate the performance of this system. The monitoring campaigns were organized every 7 days. Water quality samples were collected at the inlet, at intermediate points (i.e. at the end of each treatment stage) and at the outlet of the system. Temperature, electrical conductivity, pH and DO were measured in-situ with the use of appropriate instruments at the same points of water sample collection. Water samples were analyzed for BOD, COD, TKN, ammonia, nitrate, nitrite, total phosphorus (TP), ortho-phosphate (OP), total suspended solids (TSS) and total coliforms (TC). Mean removal efficiencies for the monitoring period were: 86.5% for BOD, 84.6% for COD, 83.7% for TKN, 82.2% for ammonia, 63.1% for OP, 63.3% for TP, 79.3% for TSS and 99.9% for TC. Furthermore, based on statistical testing, TKN, ammonia and TP removal efficiencies showed dependence on temperature. The paper presents facility description, study details and monitoring results. The study shows that the use of constructed wetlands in wastewater treatment is a good option for single-family residences in rural areas.