scholarly journals Energy-saving diagnosis model of central air-conditioning refrigeration system in large shopping mall

2021 ◽  
Vol 7 ◽  
pp. 4035-4046
Author(s):  
Wenqiang Jing ◽  
Junqi Yu ◽  
Wei Luo ◽  
Chujun Li ◽  
XinYi Liu
2013 ◽  
Vol 664 ◽  
pp. 960-963 ◽  
Author(s):  
Cai Xia Zhu ◽  
Xiu Yong Zhao ◽  
Rui Liang Yang ◽  
Zi Long Xu

The problem of air conditioning and refrigeration system for a shopping mall is diagnosed in detail. Subsequently, transformation of air conditioning and refrigeration system is carried out. One-time investment, operating costs and payback period of this transformation is analyzed in detail. Result of this transformation shows this transformation is more successful.


2012 ◽  
Vol 516-517 ◽  
pp. 1224-1228
Author(s):  
Na Liang ◽  
Rui Li

Due to energy reserves reduces gradually and uneven distribution, all countries pay more and more attention to energy saving and improve the effective utilization of energy, China also attaches great important to this. Energy saving of buildings is a necessary development trend. Air conditioning system as a large important part of building energy consumption has a huge energy-saving potential. This article mainly introduced the related strategies of energy saving in central air conditioning water system from the following three points of view: the water treatment, the cooling tower, and the variable frequency pump.


2018 ◽  
Vol 2018 ◽  
pp. 1-9
Author(s):  
Yan Zhang ◽  
Xiaoli Chu ◽  
Yongqiang Liu

Chilled water system of central air conditioning is a typical hybrid system; variable frequency behavior with amplitude limited of pumps reflects continuous and discrete dynamic characteristics. The way of energy-saving is variable water volume, via variable frequency behavior of pumps to gain adjustment of power consumption. Facing the situation of the variable frequency pumps with parallel operation, single continuous or discrete modeling cannot reflect the hybrid features. Thus, the control method will have some questions, such as bad energy-saving effect, difficult accurate adjustment of cold capacity, and low running energy efficiency. However, hybrid system modeling can reflect hybrid dynamic behavior of pumps, which is combining continuous and discrete features. The questions of nonlinear and multiparameters can be solved by control method based on hybrid system. Here, an optimum control method is proposed with the principle of the minimum, by setting the minimum power consumption as the performance function in fixed time, which realizes variable control of pumps and accurate adjustment of temperature inside room. At last, it shows the system characteristics and energy-saving affection by hybrid system modeling and the optimum control method.


2014 ◽  
Vol 1039 ◽  
pp. 409-414
Author(s):  
Tao Han ◽  
Xue Feng Lai ◽  
Liang Wen Yan ◽  
Zai Feng Zhang

This paper introduces the components of central air-conditioning system and compares the advantages and disadvantages of the PID control and fuzzy control.Fuzzy control theory and inverter technology are combined to design the Energy-Saving Monitoring System based on the fuzzy control box of STM32F103C8T6,Siemens S7-200 PLC, ABB inverter as the hardware system and interfaces configuration of KingView as the software. Experimental results show that the water system can be variable flow controlled based on the dynamic load, central air-conditioning energy efficiency the COP has greatly improved under the premise of ensuring the comfort of central air-conditioning.


2011 ◽  
Vol 201-203 ◽  
pp. 2144-2153
Author(s):  
Hong Yu Zhou ◽  
Xiao Jian Chen ◽  
Zi Hu Chen ◽  
Ming Wei Tong

In view of the insufficiency of central air-conditioning system that FCU, water pumps and air blower’s movement connot match with the actual operating load when varying duty, an energy saving control system for central air-conditioning based on terminal temperature measuring and frequency conversion control technology is proposed. This system can real-time measure different floors’ and nods’ temperatures in the building, and export orders to control the frequency of FCU, chilled water pump, cooling water pump and cooling tower air blower. To overcome big delay, large inertia and variable condition of control object, the dnamic fzzy nural network algorithm(DFNN), is applied into the control system. According to the practical running situations, the energy saving control system has advantages as high energy saving rate, high stability, good maintainability, which may be promoted the application vigorously.


2013 ◽  
Vol 712-715 ◽  
pp. 1614-1618
Author(s):  
Jia Jia Ni ◽  
Li Tao ◽  
Yi Jun Wang ◽  
Jin Lei Wu

Through to investigation on present situation of the Changzhou Changrui Hotel air conditioning system energy consumption, by analysis the energy consumption, the power consumption of hotel central air-conditioning system charge 58% of the total electric, accounted for a large proportion. So we should take the necessary measures to reduce the expenses of air conditioning system energy consumption. According to the analysis of data on the survey, we put forward some particular energy-saving measures of central air-conditioning system of the hotel, including strengthening the building envelope insulation, energy saving technology of doors and windows, measures of roof energy saving, setting reasonable indoor temperature, adopting frequency control air-conditioning, reuse waste heat of the central air-conditioning, using the condensation water of central air conditioning to make-up water and reducing temperature of cooling tower , and drying the fresh air independently.