scholarly journals Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams

2018 ◽  
Vol 102 ◽  
pp. 102-108 ◽  
Author(s):  
Usman Mahmood ◽  
Natally Horvat ◽  
Joao Vicente Horvat ◽  
Davinia Ryan ◽  
Yiming Gao ◽  
...  
2020 ◽  
Vol 2 (4) ◽  
pp. e190074
Author(s):  
Ahmed M. Amer ◽  
Yufeng Li ◽  
David Summerlin ◽  
Constantine M. Burgan ◽  
Michelle M. McNamara ◽  
...  

2014 ◽  
Vol 59 (18) ◽  
pp. 5305-5316 ◽  
Author(s):  
S Mashouf ◽  
E Lechtman ◽  
P Lai ◽  
B M Keller ◽  
A Karotki ◽  
...  

Oncotarget ◽  
2016 ◽  
Vol 8 (1) ◽  
pp. 523-535 ◽  
Author(s):  
Jung Min Bae ◽  
Ji Yun Jeong ◽  
Ho Yun Lee ◽  
Insuk Sohn ◽  
Hye Seung Kim ◽  
...  

2017 ◽  
Vol 2017 (17) ◽  
pp. 30-35
Author(s):  
Parisa Babaheidarian ◽  
David Castañó

BJR|Open ◽  
2019 ◽  
Vol 1 (1) ◽  
pp. bjro.20180045 ◽  
Author(s):  
Daisuke Kawahara ◽  
Shuichi Ozawa ◽  
Kazushi Yokomachi ◽  
Toru Higaki ◽  
Takehiro Shiinoki ◽  
...  

Objective: The aim of the current study is to evaluate the effectiveness of reduction metal artifacts using kV-CT image with the single-energy based metal artefact reduction (SEMAR) technique by single-energy reconstruction, monochromatic CT and rED reconstructed by dual-energy reconstruction. Methods: Seven different metal materials (brass, aluminum, copper, stainless, steel, lead and titanium) were placed inside the water-based PMMA phantom. After DECT-based scan, the artefact index (AI) were evaluated with the kV-CT images with and without SEMAR by single-energy reconstruction, and raw-data based electron density (rED), monochromatic CT images by dual-energy reconstruction. Moreover, the AI with evaluated with rED and the converted ED images from the kV-CT and monochromatic CT images. Results: The minimum average value of the AI with all-metal inserts was approximately 80 keV. The AI without SEMAR was larger than that with SEMAR for the 80 kV and 135 kV CT images. In the comparison of the AI for the rED and ED images that were converted from 80 kV and 135 kV CT images with and without SEMAR, the monochromatic CT images of the PMMA phantom with inserted metal materials at 80 keV revealed that the kV-CT with SEMAR reduced the metal artefact substantially. Conclusion: The converted ED from the kV-CT and monochromatic CT images could be useful for a comparison of the AI using the same contrast scale. The kV-CT image with SEMAR by single-energy reconstruction was found to substantially reduce metal artefact. Advances in knowledge: The effectiveness of reduction of metal artifacts using single-energy based metal artefact reduction (SEMAR) technique and dual-energy CT (DECT) was evaluated the electron density conversion techniques.


Sign in / Sign up

Export Citation Format

Share Document