scholarly journals Conservative Treatment of Thrombosed Type Acute Aortic Dissection Involving the Ascending Aorta Successfully Leads to Remodeling

2019 ◽  
Vol 58 (6) ◽  
pp. e129-e130
Author(s):  
Eva Bromfield-Jansen ◽  
Vincent Jongkind ◽  
Rutger Lelij ◽  
Willem Wisselink
2011 ◽  
Vol 14 (6) ◽  
pp. 373 ◽  
Author(s):  
Saina Attaran ◽  
Maria Safar ◽  
Hesham Zayed Saleh ◽  
Mark Field ◽  
Manoj Kuduvalli ◽  
...  

<p>Management of acute Stanford type A aortic dissection remains a major surgical challenge. Directly cannulating the ascending aorta provides a rapid establishment of cardiopulmonary bypass but consists of risks such as complete rupture of the aorta, false lumen cannulation, subsequent malperfusion and propagation of the dissection.</p><p>We describe a technique of cannulating the ascending aorta in patients with acute aortic dissection that can be performed rapidly in hemodynamically unstable patients under ultrasound-epiaortic and transesophageal (TEE) guidance.</p>


2021 ◽  
Vol 104 (4) ◽  
pp. 604-609

Background: The choice of arterial inflow for acute Stanford type A aortic dissection repair remains controversial. The axillary artery should be considered as first choice for cannulation, but this technique is time-consuming. The ascending aortic cannulation provides antegrade perfusion and can be performed rapidly but there are several concerns such as aortic rupture, extension of dissection, and false lumen cannulation. Objective: To compare the establishment time of cardiopulmonary bypass (CPB) and postoperative outcomes of the two cannulation techniques that provide antegrade perfusion, which was direct true lumen cannulation on the dissected ascending aorta using epiaortic ultrasound-guided and axillary artery cannulation in Siriraj Hospital. Materials and Methods: The authors retrospectively reviewed all the 30 cases of acute aortic dissection type A using two different cannulation methods performed between February 2011 and May 2017. Direct true lumen ascending aortic cannulation was performed using the epiaortic ultrasound-guide with Seldinger technique in 12 patients, and axillary artery cannulation was performed in 18 patients. Results: The direct true lumen ascending aortic cannulation was safely performed in all patients. None of them had aortic rupture. Skin incision to CPB time was significantly faster in the epiaortic ultrasound-guided ascending aortic cannulation group at 29±8 versus 49±14 minutes (p<0.001). The 30-day mortality and postoperative adverse events, such as ischemic stroke, acute kidney injury, visceral organ and limb malperfusion showed no statistically significant difference from the axillary artery cannulation method. Conclusion: Epiaortic ultrasound-guided true lumen cannulation of ascending aorta in the treatment of acute aortic dissection type A is safe and feasible. Skin incision to CPB time can be performed faster and provided good outcome compared to the axillary artery cannulation technique. Keywords: Acute aortic dissection, Ascending cannulation, Epiaortic ultrasound


Aorta ◽  
2017 ◽  
Vol 05 (02) ◽  
pp. 57-60
Author(s):  
Pierre Demondion ◽  
Dorian Verscheure ◽  
Pascal Leprince

AbstractAorto-cutaneous fistula and false aneurysm of the ascending aorta in patients who previously underwent Stanford Type A acute aortic dissection are rare and severe complications. Surgical correction remains a demanding challenge. In a case of false aneurysm rupture during redo sternotomy, selective cannulation of the right axillary and left carotid arteries allowed an efficient method of cerebral perfusion.


2016 ◽  
Vol 4 (1) ◽  
pp. 15
Author(s):  
Xiao-yan Chen ◽  
Fan-liang Kong ◽  
Tong-guo Wu

Type A aortic dissection is a catastrophic clinical entity involving the ascending aorta. In this case report, a patient was admitted to the emergency room with a presentation resembling acute myocardial infarction (AMI) that led to the inappropriate administration of anticoagulant agents or platelet. This is a case report of a 69-year-old male patient with early misdiagnosis and analysis of type A aortic dissection with discussion on the causes of misdiagnosis in light of the literature.


Sign in / Sign up

Export Citation Format

Share Document