Electrochemical study on the corrosion behaviour of a new low-nickel stainless steel in carbonated alkaline solution in the presence of chlorides

2014 ◽  
Vol 129 ◽  
pp. 160-170 ◽  
Author(s):  
S. Fajardo ◽  
D.M. Bastidas ◽  
M. Criado ◽  
J.M. Bastidas
2015 ◽  
Vol 39 (3-4) ◽  
pp. 167-174
Author(s):  
Michal Latkiewicz ◽  
Halina Krawiec ◽  
Vincent Vignal ◽  
Paulina Erazmus-Vignal

Author(s):  
Srikant Tiwari ◽  
Suryanarayan B Mishra

Artificial material such as stainless steel (SS) is widely used for orthopaedic applications owing to its superior properties, ease of fabrication and lower cost. However, in the body environment, stainless steel can leach toxic elements such as nickel and chromium. To prevent this, a hydroxyapatite (HAp) coating having chemical characteristics very similar to the human bone was deposited on a medical-grade UNS S31254 austenitic stainless steel by a Low-velocity oxy-fuel spray gun (LVOF). The coating was characterised by using a field emission scanning electron microscope (FESEM), X-ray diffractometer (XRD) and Fourier transform infrared spectroscope (FTIR). The adhesion strength, microhardness and corrosion behaviour were studied using the Tensometre, Vickers microhardness tester and potentiodynamic polarisation with electrochemical impedance spectroscope. The bacterial adhesion and bioactivity of the coating were also evaluated. The LVOF sprayed HAp coating has shown better corrosion resistance, higher bioactivity and higher hardness than the uncoated steel. The presence of tricalcium phosphate, octa-calcium phosphate (OCP) and tetra-calcium phosphate (TTCP) was found in the coating. LVOF sprayed HAp coating is also found suitable in lowering the bacterial adhesion on the steel substrate.


1987 ◽  
Vol 112 ◽  
Author(s):  
Masaki Tsukamoto ◽  
Inga-Kari Björner ◽  
Hilbert Christensen ◽  
Hans-Peter Hermansson ◽  
Lars Werme

AbstractThe release of Am-241 during corrosion of the radioactive waste glass, JSS-A, has been studied in the presence of corrosion products and/or uncom-pacted bentonite. The corrosion behaviour of Am-241 has been analyzed using gamma spectrometry. Adsorption of Am-241 on bentonite is observed in all cases. The contents of Am-241 in centrifuged leachates are in most cases less than 1/100 of total values. The normalized elemental mass loss of Am increases initially with corrosion time, and the values in the presence of bentonite and corrosion products are larger than those in the presence of bentonite alone. This tendency is in agreement with results previously found for other elements. The release of Am is low, only about 10–20 % of the corresponding total mass loss.


Sign in / Sign up

Export Citation Format

Share Document