scholarly journals Passive Cooling Load Ratio method

2013 ◽  
Vol 64 ◽  
pp. 209-217 ◽  
Author(s):  
Ana I.F. Nunes ◽  
Marta J.N. Oliveira Panão
2021 ◽  
Vol 9 (ICRIE) ◽  
Author(s):  
Ali Aedan Shbeeb ◽  
◽  
Ala'a Abbas Mahdi ◽  
Ahmed Kadhim Hussein ◽  
◽  
...  

This study aims to investigate the effect of the cooling load ratio covered by the chilled ceiling on the age of air and comfort level in a classroom in a hot and dry climate in Iraq-Hilla city. Air age, air exchange efficiency, and concentrations of pollutants in a classroom are investigated numerically by used AIRPAK software under displacement ventilation combined with a chilled ceiling system. Four cases are studied at different values of the cooling load covered by the chilled ceiling (0%, 25%, 50%, 80%) with respect to total classroom cooling load. Cooling load removes by chilled ceiling varied from (0 to 84.5 W/m2) based on the classroom area, and its temperature varied between (17.5-22.5oC). The displacement ventilation airflow rate was kept at 0.3m3/s, and the air temperature supply varied between (19.5-24.5oC) depend on the amount of cooling load covered by displacement ventilation. The results showed that the mean local air age increasing with height. The room mean air age increase and air exchange efficiency reduce with increasing load portion, which treated by the chilled ceiling. Increasing the portion of the load treated by chilled ceiling tends to improve comfort levels.


2022 ◽  
Vol 27 ◽  
pp. 932-944
Author(s):  
Ibtissame Benoudjafer

Abstract. Practice social of people is the key to produce space and give a possibility to maintain thermal comfort and energy efficiency. The main objective of this research is to adapt the traditional strategies in the architecture actual, to achieved a thermal comfort and improve on reducing cooling load through the using of vernacular gait. Today, it is necessary to practice these systems in the current or conventional architecture of household. The study is especially for arid cities namely the region of Saoura, in the hot and dry climatic zone in Algeria, considered for this study. Two main factors is considered such as design and urban where taken into account in order to select the appropriate and specific passive cooling strategy. The results show that the passive cooling strategy of courtyard would be appropriate for arid regions, however a high thermal mass would be suitable for construction. In conclusion, this work made it possible to choose a suitable passive cooling strategy for all types of construction in hot and dry climates. Finally, this paper puts forward a set of recommendations to improve the passive design of future buildings in hot and arid climates.  


2009 ◽  
Vol 33 (12) ◽  
pp. 1375-1382
Author(s):  
Jung-Hun Choi ◽  
Yong Huh ◽  
Jae-Mean Koo ◽  
Chang-Sung Seok ◽  
Jae-Sil Park
Keyword(s):  

2013 ◽  
Vol 2013 ◽  
pp. 1-7
Author(s):  
Alireza Panjsetooni ◽  
Norazura Muhamad Bunnori ◽  
Amir Hossein Vakili ◽  
Zohreh Shirkhani ◽  
Zeinab Shirkhani

Acoustic emission (AE) is an important nondestructive evaluation (NDE) technique used in the field of structural engineering for both case local and global monitoring. In this study AE technique with a new approach was employed to investigate the process of fracture formation in reinforced concrete structure. A number of reinforced concrete (RC) one story frames were tested under loading cycle and were simultaneously monitored using AE. The AE test data was analyzed using the relaxation ratio and calm and load ratio method. Also, the relaxation ratio was dominated with approaching load to 58% of the ultimate load. In addition three levels of damage using calm and load ratio were distinguished. The trend of relaxation ratio and calm and load ratio method during loading and unloading showed that these methods are strongly sensitive with cracks growth in RC frame specimens and were able to indicate the levels of damage. Also, results showed that AE can be considered as a viable method to predict the remaining service life of reinforced concrete. In addition, with respect to the results obtained from relaxation ratio and, load and calm ratio indicated, a new chart is proposed.


Energies ◽  
2022 ◽  
Vol 15 (1) ◽  
pp. 328
Author(s):  
Roberto Bruno ◽  
Piero Bevilacqua ◽  
Daniela Cirone ◽  
Stefania Perrella ◽  
Antonino Rollo

The Trombe wall is a passive system used in buildings that indirectly transfers thermal energy to the adjacent environment by radiation and convection, and directly by the thermo-circulation that arises in the air cavity delimited between a transparent and an absorbing surface. Nevertheless, the latter is painted black to increase the energy gains, but this produces a negative visual impact and promotes the overheating risk in summer. To mitigate these aspects, a hybrid Trombe wall equipped with PV panels can be employed. The PV installation results in a more pleasing wall appearance and the overheating risk reduces because part of the absorbed solar radiation is transformed into electricity. To determine the actual performance of a such system, transient simulation tools are required to consider properly the wall thermal storage features, variation of the optical properties, air thermo-circulation, and PV power production. Alternatively, regarding the traditional Trombe wall, the literature provides a simplified empirical method based on the dimensionless parameter solar load ratio (SLR) that allows for preliminary evaluations and design. In this paper, the SLR method was calibrated to determine the monthly auxiliary energy to be supplied in buildings equipped with PV-Trombe walls in heating applications. The SLR method was tuned by a multiple linear regression by data provided by TRNSYS simulation that allowed to obtain the energy performances in actual conditions of PV-Trombe walls installed on the same building but located in different localities. The comparison between the TRNSYS results and the calibrated SLR method determined average errors ranging between 0.7% and 1.4%, demonstrating the validity of the proposed methodology.