Influence of masonry infills on seismic response of RC frames under low frequency cyclic load

2019 ◽  
Vol 183 ◽  
pp. 70-82 ◽  
Author(s):  
Ning Ning ◽  
Zhongguo John Ma ◽  
Pengpeng Zhang ◽  
Dehu Yu ◽  
Jianlang Wang
2014 ◽  
Vol 59 ◽  
pp. 28-38 ◽  
Author(s):  
Ning Ning ◽  
Wenjun Qu ◽  
Peng Zhu
Keyword(s):  

2018 ◽  
Vol 16 (9) ◽  
pp. 4053-4080 ◽  
Author(s):  
Riccardo R. Milanesi ◽  
Paolo Morandi ◽  
Guido Magenes

2020 ◽  
Vol 2020 ◽  
pp. 1-18
Author(s):  
Massimiliano Ferraioli ◽  
Angelo Lavino

Despite extensive research studies, the seismic response of infilled reinforced concrete buildings remains an open problem due to both the complexity of the interaction between the infill and the frame and the large number of parameters involved. Thus, guidelines for both modelling and analysis are still lacking and the infill walls are normally treated as nonstructural components in seismic codes. However, it may be not conservative to neglect the influence of infills. In fact, the infill masonry walls may significantly affect the stiffness, strength, and energy dissipation capacity of RC buildings, even when they are regularly distributed. Recognizing this influence and its importance on the vulnerability of infilled frames, Eurocode 8 requires amplifying seismic action effects due to infills. In this paper, the effectiveness of the Eurocode 8 design provisions for infill irregularity in plan and/or elevation was investigated. To this aim, different in-plan layouts of infill walls were selected as marginal cases for which Eurocode 8 does not require amplification of the action effects due to the presence of infills, or the additional measures to counteract these effects are not mandatory. The seismic vulnerability of the infilled RC buildings was evaluated using nonlinear static and nonlinear dynamic analyses. Both cracking and crushing of masonry and stiffness and strength degradation were considered in the analysis. The effect of the layout of the masonry infills on the seismic response in terms of resistance and displacement was evaluated. Results show that in one of the case studies here examined, it is not conservative to neglect the influence of infill panels. In fact, structural failure due to torsion and soft-storey effects may occur even in cases where Eurocode 8 does not require the amplification of the action effects. Finally, the total shear demand on columns may be underestimated, even in cases where the code provisions for infills irregularity are not mandatory, and the additional shear demand in the columns induced by the masonry infill is very low.


Author(s):  
Shigeru Aoki ◽  
Yuji Nakanishi ◽  
Kazutoshi Tominaga ◽  
Takeshi Otaka ◽  
Tadashi Nishimura ◽  
...  

Reduction of seismic response of mechanical system is important problem for aseismic design. Some types of base isolation systems are developed and used in actual base of buildings and floors in buildings for reduction of seismic response of mechanincal system. In this paper, a base isolation system utilizing bearing with friction and restoring force of bearing is proposed. Friction bearing consists of two plates having spherical concaves and oval type metal or spherical metal with rubber. First, effectiveness of the base isolation system is examined experimentally. Using artificial time histories, the isolated table is shaken on the shaking table. The maximum value of response is reduced and sum of squares of response is significantly reduced. Power spectrum is significantly reduced in almost of all frequency regions, except for very low frequency region. Next, in order to examine reduction of seismic response of actual mechanical system, a console rack is set on the isolated plate. Seismic response is also significantly reduced. Finally, obtained results of experiment are examined by simulation method. An analytical model considering friction and restoring force is used. From simulation method, effectiveness of the proposed base isolation system is demonstrated.


2020 ◽  
pp. 2150004
Author(s):  
F. Soleiman Meigooni ◽  
M. Tehranizadeh

Aftershock records have a considerable effect on the results of collapse assessments conducted on buildings. Thus, they should be selected cautiously. As the number of recorded aftershocks is not sufficient, mainshock records are often utilized instead. In order to increase the correlation between the aftershock time history and the seismic response of a structure, this research intends to investigate several Intensity Measures (IMs). For this study, three RC frames were considered. Forty-four far-field records from FEMAP-695 were selected as main and aftershock. Each building analysis was conducted under 44 mainshock–aftershock chains. According to the results, use of the summation of the first mode spectral acceleration value of aftershocks as the second part of a vector IM can lead to the sufficiency of the IM.


Sign in / Sign up

Export Citation Format

Share Document