Behavior of concrete masonry infills bounded by masonry frames subjected to in-plane lateral loading – Experimental study

2021 ◽  
Vol 247 ◽  
pp. 113153
Author(s):  
Soraya Roosta ◽  
Yi Liu
2019 ◽  
Vol 46 (10) ◽  
pp. 896-908 ◽  
Author(s):  
Ehsan Nasiri ◽  
Yi Liu

A numerical study using a three-dimensional finite element model was conducted to investigate the arching behaviour and strength of concrete masonry infills bounded by reinforced concrete frames subjected to out-of-plane loading. Physical specimens were concurrently tested to provide results for validation of the model as well as evidence of directional characteristics of arching behaviour of masonry infills. A subsequent parametric study using the model included a wide range of infilled frame geometric properties. The results showed in detail the difference in one-way and two-way arching in terms of both strength and failure mechanism, and the contributing factors to this difference. Evaluation of the two main design equations for out-of-plane strength of masonry infills led to proposal of modifications to provide a more rational consideration of directional behaviour of concrete masonry infills. A comparison study using the available test results showed a marked improvement of strength prediction based on the proposed modification.


2017 ◽  
Vol 21 ◽  
pp. 22-32
Author(s):  
Prachand Man Pradhan ◽  
Ramesh Kumar Maskey ◽  
Prajwal Lal Pradhan

The partially infilled frames are considered vulnerable in terms of captive column effect for the events of earthquakes. Many reinforced concrete buildings have been affected due to captive column effects. Experimental study has been done to verify the captive column effect and its failure modes for partially infilled frames and the results have been compared with the ones obtained for a bare frame subjected to lateral loading. The results of experimental study have also been compared with some analytical results and the verification of equivalent strut width proposed by one of the authors has been done. From the experimental point of view, it is understandable that due to lateral loading to partially infilled frames, the damage pattern is diagonal and the failure of column occurs at the column-wall joint at the upper side of the wall. It is also seen that for fifty percent partially infilled frames, the stiffness of bare frame is enhanced slightly, however, the failure in the column during lateral loading indicates that the columns are subjected to high shear due to the presence of partial infill.


Sign in / Sign up

Export Citation Format

Share Document