Phenomena of single water droplet impacting a heptane layer on water pool

Author(s):  
Xu Zhang ◽  
Changjian Wang ◽  
Shengchao Rui
Keyword(s):  
2012 ◽  
Vol 17 (1) ◽  
pp. 14-19
Author(s):  
Jae-Bong Lee ◽  
Joo-Hyun Moon ◽  
Seong-Hyuk Lee

2018 ◽  
Author(s):  
Luca Doretti ◽  
Hossein Sadafi ◽  
Giulia Righetti ◽  
Kamel Hooman ◽  
Giovanni Antonio Longo ◽  
...  

2018 ◽  
Author(s):  
Pei Zhang ◽  
Chuang Sun ◽  
Fengxian Sun ◽  
Zicheng Jin

Author(s):  
Emerson Barbosa dos Anjos ◽  
Carolina Palma Naveira Cotta ◽  
Renato Machado Cotta ◽  
Igor Soares Carvalho ◽  
Manish Tiwari

2020 ◽  
Vol 68 (2) ◽  
pp. 137-145
Author(s):  
Yang Zhouo ◽  
Ming Gao ◽  
Suoying He ◽  
Yuetao Shi ◽  
Fengzhong Sun

Based on the basic theory of water droplets impact noise, the generation mechanism and calculation model of the water-splashing noise for natural draft wet cooling towers were established in this study, and then by means of the custom software, the water-splashing noise was studied under different water droplet diameters and water-spraying densities as well as partition water distribution patterns conditions. Comparedwith the water-splashing noise of the field test, the average difference of the theoretical and the measured value is 0.82 dB, which validates the accuracy of the established theoretical model. The results based on theoretical model showed that, when the water droplet diameters are smaller in cooling tower, the attenuation of total sound pressure level of the water-splashing noise is greater. From 0 m to 8 m away from the cooling tower, the sound pressure level of the watersplashing noise of 3 mm and 6 mm water droplets decreases by 8.20 dB and 4.36 dB, respectively. Additionally, when the water-spraying density becomes twice of the designed value, the sound pressure level of water-splashing noise all increases by 3.01 dB for the cooling towers of 300 MW, 600 MW and 1000 MW units. Finally, under the partition water distribution patterns, the change of the sound pressure level is small. For the R s/2 and Rs/3 partition radius (Rs is the radius of water-spraying area), when the water-spraying density ratio between the outer and inner zone increases from 1 to 3, the sound pressure level of water-splashing noise increases by 0.7 dB and 0.3 dB, respectively.


Lab on a Chip ◽  
2021 ◽  
Author(s):  
Takumi Inui ◽  
Jiyang Mei ◽  
Chikahiro Imashiro ◽  
Yuta Kurashina ◽  
James Friend ◽  
...  

After exposing a plated C2C12 cells culture to PBS, ultrasound from the SAW device transmitted into the cell culture via a coupling water droplet. We can remove cells from an area 6 × 10−3 mm2, equivalent to about 12 cells.


Sign in / Sign up

Export Citation Format

Share Document