In order to simulate the transfer of mass, momentum and energy in the gas-liquid two-phase flow system, tremendous work focused on the phenomenon, mechanisms and models for two-phase flow in different channels, such as circular pipe, rectangular channel, rod bundle and annulus. Drift-flux model is one of the widely used models for its simplicity and good accuracy, especially for the reactor safety analysis codes (RELAP5 and TRAC et al.) and sub-channel analysis code (COBRA, SILFEED and NASCA et al.). Most of the adopted drift-flux models in these codes were developed based on the void fraction measured in pipe and annulus, which were different with the actual nuclear reactor. Although some drift-flux models were developed for rod bundles, they were based on the void fraction on the whole cross-section not in subchannel in rod bundles due to the lack of effective measuring methods. A novel sub-channel impedance void meter (SCIVM) has been developed to measure the void fraction in sub-channel of 5 × 5 rod bundles, which is adopted to evaluate these existing drift-flux models for rod bundles. By comparison, the values of drift-flux parameters have large differences among different correlations, which are suggested to be reconsidered. Based on the experimental data and physical laws, Lellouche-Zolotar and Chexal-Lellouche correlations show a better performance for drift velocity. If the predicting error of void fraction is the only concerned parameter, Chen-Liu, Ishizuka-Inoue and Chexal-Lellouche correlations are recommended for averaged relative error less than 30%. More experiments are suggested to focus on the distribution parameter and drift velocity through their definition.


2021 ◽  
Vol 53 (1) ◽  
pp. 61-68
Author(s):  
Jiancheng Zhou ◽  
Tianzhou Ye ◽  
Dalin Zhang ◽  
Gongle Song ◽  
Rulei Sun ◽  
...  

2017 ◽  
Vol 2017 ◽  
pp. 1-13 ◽  
Author(s):  
Xiu Xiao ◽  
Qingzi Zhu ◽  
Shao-Wen Chen ◽  
Mamoru Ishii ◽  
Yajun Zhang ◽  
...  

An experimental study on air-water two-phase flow under vibration condition has been conducted using double-sensor conductivity probe. The test section is an annular geometry with hydraulic diameter of 19.1 mm. The vibration frequency ranges from 0.47 Hz to 2.47 Hz. Local measurements of void fraction, interfacial area concentration (IAC), and Sauter mean diameter have been performed along one radius in the vibration direction. The result shows that local parameters fluctuate continuously around the base values in the vibration cycle. Additional bubble force due to inertia is used to explain lateral bubble motions. The fluctuation amplitudes of local void fraction and IAC increase significantly with vibration frequency. The radial distribution of local parameters at the maximum vibration displacement is specifically analyzed. In the void fraction and IAC profiles, the peak near the inner wall is weakened or even disappearing and a strong peak skewed to outer wall is gradually observed with the increase of vibration frequency. The nondimensional peak void fraction can reach a maximum of 49% and the mean relative variation of local void fraction can increase to more than 29% as the vibration frequency increases to 2.47 Hz. But the increase of vibration frequency does not bring significant change to bubble diameter.


Author(s):  
Hideo Ide ◽  
Tohru Fukano

Air-liquid two-phase flow in a horizontal flat capillary rectangular channel has been studied to clarify the effects of concentration of surfactant solution on the flow phenomena, such as flow patterns, pressure drop, void fraction and so on. The concentrations of surfactant solution were 0, 10, 50 and 100 ppm and the surface tension of each solution was reduced to about 34mN/m from that of pure water of about 72mN/m. The dimension of the channel used was 10.0 mm × 1.0 mm. The drag reduction by mixing the surfactant was examined in both the single phase flow and the two-phase flow. The experimental data of two-phase frictional pressure drop and holdup were compared with the respective correlations which were previously proposed by the other researchers and the present authors. Finally, we proposed new correlations of two-phase frictional pressure drop and holdup in which the effect of surface tension and the aspect ratio of cross section of channel were taken into account.


2021 ◽  
Author(s):  
Qingche He ◽  
Liangming Pan ◽  
Luteng Zhang ◽  
Meiyue Yan ◽  
Wangtao Xu

Abstract Two-phase Flow is widely involved in reactor design and is directly relevant to reactor safety. However, the flow regime in narrow rectangular channels still needs further study because it has a considerable difference from tube and bundle channels. To investigate the two-phase flow regime and interfacial structure characteristics, the air-water experiment with an adiabatic vertical channel of 4 × 66 × 1800, 6 × 66 × 1800 mm have been conducted under atmosphere pressure condition. The impedance void meter was used to measure the global void fraction in narrow rectangular channels. A high-speed camera was used to record the profiles of the flow regime. The flow regime was identified by the random forest clustering algorithm based on a training sample. The profiles of different parameters, including void fraction, pressure loss at Z/D = 150, were analyzed in this paper. Furthermore, based on the parameters’ distribution, the regime transition criteria in narrow rectangular channels were discussed. It is shown that the transition from bubble to slug flow always occurred when the average void fraction is 0.17–0.2. The transition value is 0.57–0.62 when the slug Flow changes to the churn-turbulent Flow and 0.78–0.8 from churn-turbulent to annular Flow. The constant used in the Lockhart-Martinelli correlation is found to calculate the frictional pressure drop in a rectangular channel. Furthermore, the drift-model applied to the rectangular channel is verified.


Author(s):  
Hideo Ide ◽  
Tohru Fukano

Air-liquid two-phase flow in a horizontal flat capillary rectangular channel has been studied to clarify the effects of surface tension on the flow phenomena, such as flow patterns, holdup and frictional pressure drop and so on. The concentrations of surfactant solution were 0, 10, 50 and 100 ppm and the surface tension of each solution was reduced to about 34mN/m from that of pure water of about 72mN/m. The dimension of the channel used was 10.0 mm×1.0 mm. The drag reduction by mixing the surfactant was examined in both the single phase flow and the two-phase flow. The experimental data of void fraction and two-phase frictional pressure drop were compared with the respective correlations which were previously proposed by the other researchers. Finally, we proposed new correlations of two-phase frictional pressure drop in which the effect of surface tension and the aspect ratio of cross section of channel were taken into account.