Su1354 High Diagnostic Accuracy and Safety of the 22G Sharkcore Needle for Eus-Fine Needle Biopsy: A Retrospective Study From Two Tertiary Centers in UK

2017 ◽  
Vol 85 (5) ◽  
pp. AB347
Author(s):  
Leonardo Henry Eusebi ◽  
Satish Mogan ◽  
Gavin Johnson ◽  
Stephen P. Pereira ◽  
Sheida Vessal ◽  
...  
2021 ◽  
Author(s):  
Gabriele Delconte ◽  
Federica Cavalcoli ◽  
Andrea Magarotto ◽  
Giovanni Centonze ◽  
Cristina Bezzio ◽  
...  

Introduction: Fine Needle Biopsy (FNB) has been suggested to provide better histological samples as compared to endoscopic ultrasound fine needle aspiration (EUS-FNA). However, studies comparing EUS-FNA and EUS-FNB for pancreatic lesions reported contrasting results. The aim of this study was to compare the clinical performance of EUS-FNA versus EUS-FNB with ProCore needle for the investigation of pancreatic lesions. Methods: We reviewed all patients undergoing EUS for the investigation of pancreatic lesions from August 2012 to September 2018. From August 2012 to January 2015 all procedures were performed with standard needles, whereas from February 2015 to September 2018 the use of ProCore needles had been introduced. Data on diagnostic accuracy, number of needle passes and/or adverse events were collected. Results: 324 patients were retrospectively evaluated: 190 (58.6%) underwent EUS-FNA and 134 (41.4%) EUS-FNB. Both EUS-FNA and EUS-FNB showed high diagnostic accuracy for malignancy [94% (CI 95%:89-97%) vs 94% (CI 95%:89-98%)]. Notable, there were no differences between EUS-FNA and EUS-FNB in terms of sensitivity, specificity, positive and negative likelihood ratio, histological core tissue retrieval, adverse events or number of needle passes. However, subgroup analysis noted a higher diagnostic accuracy for 25G EUS-FNB as compared to 25G EUS-FNA (85,7% vs 55,5%; *p=0.023). Conclusion: EUS-FNB with ProCore needle is safe and feasible in pancreatic lesions. ProCore needle did not provide any advantage in terms of diagnostic accuracy, sensitivity, specificity, positive and/or negative likelihood ratio, or acquisition of core specimen, therefore its routine application is not


1984 ◽  
Vol 25 (4) ◽  
pp. 273-276 ◽  
Author(s):  
M. Kehler ◽  
U. Albrechtsson

Results with a previously described device for fine needle biopsies of non-palpable breast lesions are reported. During the past 5 years 182 biopsies were performed and 133 of these yielded diagnostic cell material. In the series, 41 carcinomas were found and fine needle biopsy in all demonstrated malignant or probably malignant cells. In the biopsies evaluated as benign or probably benign, malignancy has not been found during the observation period of 4 to 59 months (mean 21.5 months). The device described is cheap and biopsy is easily performed and, if necessary, repeated in a short time. The diagnostic accuracy is high and carcinomas as small as 3 mm in diameter have been diagnosed.


2020 ◽  
Vol 91 (6) ◽  
pp. AB319
Author(s):  
Liza Plafsky ◽  
Tara Keihanian ◽  
Jinendra L. Satiya ◽  
Liege I. Diaz ◽  
Mohit Girotra

OTO Open ◽  
2020 ◽  
Vol 4 (3) ◽  
pp. 2473974X2094918
Author(s):  
Jennifer L. Harb ◽  
Dara Bakar ◽  
Jagdish K. Dhingra

Objective To assess the diagnostic accuracy of fine-needle biopsy (FNB) of salivary gland neoplasms via ultrasound (US) or palpation guidance by an otolaryngologist in a community practice. Study Design Retrospective chart review. Setting Community otolaryngology practice. Methods Retrospective analysis was conducted for all office-based salivary gland FNBs from a community practice from 2005 through 2018. There were 433 FNBs performed among 370 patients. The likelihood of achieving a diagnostic result based on method (US vs palpation guidance) was calculated. Of this cohort, 196 cases had surgical follow-up (parotid gland, n = 168; submandibular gland, n = 28). Correlation of preoperative FNB results to final surgical pathology was performed and measures of diagnostic accuracy computed. Results US-guided FNBs were more likely to achieve a diagnostic result than FNBs obtained via palpation guidance ( P = .00002). Parotid gland FNBs demonstrated a sensitivity and specificity of 78.57% and 92.44%, respectively. Submandibular FNBs demonstrated a sensitivity and specificity of 57.14% and 93.74%. Conclusion FNBs performed under US guidance are more likely to achieve a diagnostic specimen than those performed under palpation guidance. FNBs of parotid gland tumors may be assessed with diagnostic accuracy in the community setting that is similar to that achieved at tertiary care centers. Further research is needed to ascertain whether this finding extends to FNBs of submandibular gland tumors. Offering this procedure at point of care in the community may improve compliance and reduce wait time.


2003 ◽  
Vol 58 (2) ◽  
pp. 69-74 ◽  
Author(s):  
André Piovesan de Farias ◽  
Daniel Deheinzelin ◽  
Riad N. Younes ◽  
Rubens Chojniak

PURPOSE: To report the experience of a radiology department in the use of computed tomography guided biopsies of mediastinal lesions with fine and cutting needles, describing the differences between them. The results of adequacy of the sample and histologic diagnoses are presented according to the type of needle used. METHODS: We present a retrospective study of mediastinal biopsies guided by computed tomography performed from January 1993 to December 1999. Eighty-six patients underwent mediastinal biopsy in this period, 37 with cutting needles, 38 with fine needles, and 11 with both types (total of 97 biopsies). RESULTS: In most cases, it was possible to obtain an adequate sample (82.5%) and specific diagnosis (67.0%). Cutting-needle biopsy produced a higher percentage of adequate samples (89.6% versus 75.5%, P = 0.068) and of specific diagnosis (81.3% versus 53.1%, P = 0.003) than fine-needle biopsy. There were no complications that required intervention in either group. CONCLUSION: Because they are practical, safe, and can provide accurate diagnoses, image-guided biopsies should be considered the procedure of choice in the initial exploration of patients with mediastinal masses. In our experience, cutting needles gave higher quality samples and diagnostic rates. We recommend the use of cutting needles as the preferred procedure.


2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Lachlan R. Ayres ◽  
Elizabeth K. Kmiotek ◽  
Eric Lam ◽  
Jennifer J. Telford

Background and Aims. Endoscopic ultrasound (EUS) guided fine-needle aspiration (FNA) is the method of choice for sampling pancreatic lesions. This study compares the diagnostic accuracy and safety of FNB using a novel core needle to FNA in solid pancreatic lesions. Methods. A retrospective review of patients in whom EUS FNA or FNB was performed for solid pancreatic lesions was conducted. Diagnostic performance was calculated based upon a dual classification system: classification 1, only malignant pathology considered a true positive, versus classification 2, atypical, suspicious, and malignant pathology considered a true positive. Results. 43 patients underwent FNB compared with 51 FNA. Using classification 1, sensitivity was 74.0% versus 80.0%, specificity 100% versus 100%, and diagnostic accuracy 77.0% versus 80.0% for FNB versus FNA, respectively (all p>0.05). Using classification 2, sensitivity was 97% versus 94.0%, specificity 100% versus 100%, and diagnostic accuracy 98.0% versus 94.0% for FNB versus FNA, respectively (all p>0.05). FNB required significantly fewer needle passes (median = 2) compared to FNA (median = 3; p<0.001). Adverse events occurred in two (4.5%) FNB patients compared with none in the FNA group (p>0.05). Conclusion. FNA and FNB have comparable sensitivity and diagnostic accuracy. FNB required fewer passes.


Sign in / Sign up

Export Citation Format

Share Document