Does atrial size and function vary in paroxysmal versus chronic atrial fibrillation?

2008 ◽  
Vol 17 ◽  
pp. S42
Author(s):  
Angela Worthington ◽  
Liza Thomas
PLoS ONE ◽  
2016 ◽  
Vol 11 (1) ◽  
pp. e0147015 ◽  
Author(s):  
Adam Goldberg ◽  
Kenya Kusunose ◽  
Salima Qamruddin ◽  
L. Leonardo Rodriguez ◽  
Todor N. Mazgalev ◽  
...  

PLoS ONE ◽  
2015 ◽  
Vol 10 (7) ◽  
pp. e0129274 ◽  
Author(s):  
Bin Xiong ◽  
Dan Li ◽  
Jianling Wang ◽  
Laxman Gyawali ◽  
Jinjin Jing ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Ricardo A. Gonzales ◽  
Felicia Seemann ◽  
Jérôme Lamy ◽  
Per M. Arvidsson ◽  
Einar Heiberg ◽  
...  

Abstract Background Segmentation of the left atrium (LA) is required to evaluate atrial size and function, which are important imaging biomarkers for a wide range of cardiovascular conditions, such as atrial fibrillation, stroke, and diastolic dysfunction. LA segmentations are currently being performed manually, which is time-consuming and observer-dependent. Methods This study presents an automated image processing algorithm for time-resolved LA segmentation in cardiac magnetic resonance imaging (MRI) long-axis cine images of the 2-chamber (2ch) and 4-chamber (4ch) views using active contours. The proposed algorithm combines mitral valve tracking, automated threshold calculation, edge detection on a radially resampled image, edge tracking based on Dijkstra’s algorithm, and post-processing involving smoothing and interpolation. The algorithm was evaluated in 37 patients diagnosed mainly with paroxysmal atrial fibrillation. Segmentation accuracy was assessed using the Dice similarity coefficient (DSC) and Hausdorff distance (HD), with manual segmentations in all time frames as the reference standard. For inter-observer variability analysis, a second observer performed manual segmentations at end-diastole and end-systole on all subjects. Results The proposed automated method achieved high performance in segmenting the LA in long-axis cine sequences, with a DSC of 0.96 for 2ch and 0.95 for 4ch, and an HD of 5.5 mm for 2ch and 6.4 mm for 4ch. The manual inter-observer variability analysis had an average DSC of 0.95 and an average HD of 4.9 mm. Conclusion The proposed automated method achieved performance on par with human experts analyzing MRI images for evaluation of atrial size and function.


2020 ◽  
Vol 29 ◽  
pp. S174
Author(s):  
D. Makarious ◽  
A. Bhat ◽  
S. Khanna ◽  
H. Chen ◽  
A. Drescher ◽  
...  

Author(s):  
Andy C. Kiser ◽  
Mark D. Landers ◽  
Ker Boyce ◽  
Matjaž šinkovec ◽  
Andrej Pernat ◽  
...  

Objective Transmural and contiguous ablations and a comprehensive lesion pattern are difficult to create from the surface of a beating heart but are critical to the successful treatment of persistent, isolated atrial fibrillation. A codisciplinary simultaneous epicardial (surgical) and endocardial (catheter) procedure (Convergent procedure) addresses these issues. Methods Patients with symptomatic atrial fibrillation who failed medical treatment were evaluated. Using only pericardioscopy, the surgeon performed near-complete epicardial isolation of the pulmonary veins and a “box” lesion on the posterior left atrium using unipolar radiofrequency ablation. Simultaneous endocardial catheter radiofrequency ablation completed pulmonary vein isolation, performed a mitral annular and cavotricuspid isthmus line of block, and debulked the coronary sinus. Twelve-month results for the Convergent procedure were compared with 12-month results for concomitant and pericardioscopic (stand-alone transdiaphragmatic/thoracoscopic) atrial fibrillation procedures using unipolar radiofrequency ablation. Results Sixty-five patients underwent the Convergent procedure (mean age, 62 y; mean body surface area, 2.17 m2; mean atrial fibrillation duration, 4.8 y; mean left atrial size, 5.2 cm). Ninety-two percent were in persistent or long-standing persistent atrial fibrillation. At 12 months, evaluation with 24-hour Holter monitors found 82% of patients in sinus rhythm, while only 47% of pericardioscopic and 77% of concomitant patients treated with unipolar radiofrequency ablation were in sinus rhythm. Conclusions Simultaneous epicardial and endocardial ablation improves outcomes for patients with persistent or longstanding persistent atrial fibrillation. This successful collaboration between cardiac surgeon and electrophysiologist is an important treatment option for patients with large left atriums and chronic atrial fibrillation.


2010 ◽  
Vol 105 (9) ◽  
pp. 1317-1326 ◽  
Author(s):  
Vinodh Jeevanantham ◽  
William Ntim ◽  
Sankar D. Navaneethan ◽  
Sidharth Shah ◽  
Alex C. Johnson ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document